XVME-200/290 Manual
December, 1987
Table 2-2. Base Address Jumper Options (Cont’d)
JA15
JA14
JAI3
JA12
JAI1
JAI0
Base Address of
Module
OUT OUT OUT I N OUT IN E800H
OUT OUT OUT IN OUT OUT EC00H
OUT OUT OUT OUT IN I N F 0 0 0 H
OUT
OUT
OUT
OUT IN
OUT
F400H
OUT
OUT
OUT
OUT
OUT
I N
F8OOH
OUT OUT OUT OUT OUT OUT FC00H
2.4.2
Address Modifier Jumper
The DIO Module has one jumper that determines which Address Modifier Codes it
will respond to.
This jumper is labeled as J2 (see Figure 2-1 for the jumper
location). Jumper J2 determines whether the module will respond to supervisory or
to non-privileged short I/O VMEbus cycles.
When jumper J2 is in, the module will
respond to supervisory short I/O bus cycles only.
When jumper J2 is out, the
module will respond to both non-privileged and supervisory short I/O bus cycles.
Table
2-3
shows the relationship between jumper J2 and the Address Modifiers.
Table 2-3. Addressing Options
Jumper J2
Address Modifier that the DIO
Module will respond to
In
out
(2DH) Supervisory Only
(2DH) Supervisory or (29H) Non-privileged
2-7