3.3 Nitrogen filling time display(C): display the current setting of nitrogen filling time
(unit: 1/s)
3.4 Sealing time display(D): display the current setting of sealing time (unit: 0.1/s)
3.5 Cooling time display(E): display the current setting of cooling time (unit: 0.1/s)
3.6 Memory release key(F): press key for modifying memory function
3.7 Memory input key(G): press key for locking memory function
3.8 Reserved key(H): key reserved for further use.
3.9 E-stop key(I): make timing function stop, and release the upper lid.
3.10 Time increase key(J): press key for time adding
3.11 Time decrease key(K): press key for time reducing
3.12 Sequence of trial run:
3.12.1 Connect the power.
3.12.2
If the running condition sounds smoothly, it’s clockwise rotating. If the machine
doesn’t work, please turn off the machine immediately. Then, change the power
wires.
※
Attention: remember to ground the machine.
3.12.3 Packaging test:
(A)
Test the sealing temperature and adjust the sealing time in accordance with Chapter 3
page 10(D).
(B)
Test the vacuum degree and adjust the vacuum time in accordance with Chapter 3 page
10(B).
3.12.4 If everything is OK, operate the machine according to the instructions in Chapter 4 for
normal production.