XtraVac CM800 Chamber Machine Operation and Parts Manual
XtraVac Packaging Machines 419 E. 11th Ave. North Kansas City, MO 64116 USA
CM800 Chamber Machine +1 (800) 729-2999 [email protected]
15
Chapter 4
:
Instructions of operation, maintenance and
troubleshooting
4.1 Operation sequence:
4.1.1 Press power switch, then the indicator of the display screen is lit.
4.1.2 Press “memory release” key, then the display screen starts flashing.
4.1.3 Press “
↑
” or “
↓
” to input set number and time.
4.1.4 Then, press “Memory input” key to set program. After that, start packaging process.
4.1.5 If it’s necessary to stop or change program memory function during vacuum or sealing
process, press E-stop key (I) to achieve it. Only press the upper lid will re-start the
normal process.
※
Attention: keep hands away from the packaging area.
4.2 Maintenance:
4.2.1 Cleaning of vacuum chamber
4.2.1.1 If the working process is finished, use clean and wet cloth to wipe the vacuum
chamber and sealing set.
4.2.2 Vacuum oil replacement.
4.2.2.1 Recommended vacuum oil: BP Engergol RC100, Esso Nuto H100, Mobil Rarus 427.
4.2.2.2 Drain the oil completely before filling new oil.
4.2.2.3 Oil capacity should be kept at least two-thirds of total amount.
4.2.3 If the heat-resistance cloth on the heater is damaged, please replace it immediately.
4.2.4 Change the oil of the vacuum pump for every 300 hours. If the packaged product is full
of juice, shorten the oil replacing cycle time. Also check the oil level from oil sight
glass every week. Oil capacity should be kept at least two-thirds of total amount. If the
oil is dirty, please replace it immediately.
4.2.5 The disposal of discarded material should be in accordance with the local environmental
regulations.
4.2.6 Detail drawing of the oil pump
Summary of Contents for CM800
Page 1: ......