Allowed Source
Factory default filter set for the ‗IP address‘ is ‗
0.0.0.0
‘ and the ‗Subnet Mask‘ is ‗
0.0.0.0
‘ in ‗
Allowed Source
‘
setting. If the incoming packet fulfills the following criterion, XL-HCW224C will accept the management packet, else
reject it.
(
Incoming Source IP Address
&
Subnet Mask
) = (
IP Address
&
Subnet Mask
)
For the factory default setting, it will accept all incoming packets.
For example, the following filter set permits all Hosts with IP address ‗192.168.1.xxx‘ to access and configure XL-
HCW224C,
For each programmed filter set, you can further specify if the protocol Telnet/Http/Snmp/Ping is enabled or not. Be
careful not to block your current IP from accessing XL-HCW224C remotely; else you have to press the Reset
Button locally and restart XL-HCW224C from factory default settings.