Coax MDU Master Bridge User
’s Guide
4
You can also use other Combiner or Mixer-Splitter with XL-HCW224C to build the same system, see the
following
Figure 5
for different cabling,
Satellite/CATV
VHF/UHF
Mixer
Combiner
XL-HC224C
XL-HCW224C
Splitter
PON
Optical Fiber
ISP
Figure 5: Different Cabling of XL-HCW224C
NOTE:
After power up XL-HCW224C, the led ‗
Link/Act
‘ will light up for at least one EP is detected on the HCNA
network. A dimmed led ‗
Link/Act
‘ shows no EP attached to the HCNA network.
NOTE:
The minimum attenuation between Master and EP is 6dB. EP is usually connected to the coaxial cable via a
Tap
device that provides enough attenuation (contributes more than 20dB). If you intend to connect the Master and
EP directly for test purpose, please add the attenuator that exceeds 6dB to the coaxial cable.
Verification
After you have finished the installation, you should be able to access XL-HCW224C through
Ethernet
link (port
LAN1/LAN2). Host (PC) at EP is not allowed to access the XL-HCW224C itself, but can reach the
Ethernet
link
(toward ISP)
of XL-HCW224C through
HCNA
link to verify the installation is completed. (See next Chapter for details).