background image

SeaAir Regulator

4

SeaAir Regulator Service and Repair Manual

 

Facility Requirements

"Jaws" Gripmaster Vise

Ultrasonic Cleaner

As an Authorized XS Scuba Dealer, your customers expect you to 

provide top-notch overhaul service, both before and after the sale.  Next to 

airfills and gas blending, it is the single most important commodity your 

store can provide.

The service department is therefore the most important part of your 

store.  It should be clean and well lighted, and stocked with a complete in-

ventory of parts and all the specialty tools you will need to get the job done 

right.  As a minimum requirement, your service facility should be equipped 

with the following items:

 

Ultrasonic Cleaner – Select the right size model that can keep up with 
the volume of equipment that your store services.  A built in timer and 
heater will help control the cleaning time and temperature of the solu-
tion, since most solutions work best when heated.

 

Bench Mounted Vise – A vise is sometimes needed to hold the regula-
tor secure – especially when removing the first stage yoke retainer.  
Special care must be taken, however, to avoid damage that can result 
from improper use of this tool.  Be sure to follow the instructions pro-
vided in this manual. 
NOTE:  XS Scuba especially endorses and recommends the Jaws 
Gripmaster Bench Vise
, available from Peter Built Co.  It is designed 
specifically for the professional dive store service bench, and will pre-
vent damage that can easily be caused by a conventional vise.

 

Magnification Lamp – Strong lighting and magnification are essential 
requirements for performing a thorough parts inspection - especially 
when locating the source of a small leak.

 

Quality Wrenches & Sockets – When working with brass parts, it is 
especially critical to use the correct size wrench and to ensure that it 
fits properly over the part.  The use of an adjustable wrench is very 
likely to cause damage to your customer's equipment, and should be 
strictly avoided at all times.

 

Calibrated Inch-Pound and Foot-Pound Torque Wrenches – 
It is important to follow the manufacturer's torque values whenever they 
are specified, in order to avoid overtightening or undertightening a part.  
This is especially important for smaller parts and fittings, when over-
tightening can easily damage the part.

  

Torque wrenches that can be 

set for both inch-pound and foot-pound measurements tend to be less 
accurate than wrenches that are designed to measure torque within a 
specific range.

Summary of Contents for SEAAIR

Page 1: ...Service Repair Manual SERVICE AND REPAIR MANUAL SEAAIR REGULATOR PN RG200 Revised 02 11...

Page 2: ...ocedures General Guidelines 8 First Stage Disassembly 9 Second Stage Disassembly 13 Section 4 Reassembly Procedures General Guidelines 16 First Stage Reassembly 17 Second Stage Reassembly 21 Section 5...

Page 3: ...supporting product it is extremely critical that it receives service according to the procedures outlined in this manual on a regularly scheduled basis at least once a year with normal or infrequent...

Page 4: ...result from improper use of this tool Be sure to follow the instructions pro vided in this manual NOTE XS Scuba especially endorses and recommends the Jaws Gripmaster Bench Vise available from Peter...

Page 5: ...IP RANGE 125 150 PSI PSI PETER BUILT Quality in the making 419 468 2212 USE NO OIL 140 25 50 150 125 100 75 175 200 225 250 275 300 0 IP RANGE 125 150 PSI PSI USE NO OIL PETER BUILT CO Quality in the...

Page 6: ...t exposes the brass beneath the finish CAUTION Do not clean any parts that show damage to their finish inside an ultrasonic cleaner 4 Closely examine all parts of the first stage for any other signs o...

Page 7: ...i may result in damage or rupture of the test gauge or LP hose and could cause serious personal injury 2 Slowly open the supply valve to pressurize the first stage Close ly monitor the IP test gauge t...

Page 8: ...rings After passing close inspection static O rings may sometimes be reused although this is not neces sarily recommended Dynamic O rings must be automatically discarded and replaced with every servi...

Page 9: ...ntal damage to soft metal parts If an ordinary bench vise will be used the first stage must be mounted outside the vise with the use of a vise mounting tool fastened into the high pressure port To ens...

Page 10: ...hex key to the DIN retainer 4f and turn it counter clockwise to loosen and remove from the body along with the handwheel 4a and saddle 4d c Remove the DIN retainer from the handwheel and then re move...

Page 11: ...ect the spring with a magnifier to check for any signs of damage or corrosion that has permeated the wall of the metal Set the spring aside to be reused if it is determined to be in satisfactory condi...

Page 12: ...nd discard both O rings 27 28 from the swivel cap and automatically discard them regardless of their condition 22 Using a smooth plastic or brass probe remove the rubber col lar 26 from the piston cap...

Page 13: ...ll require the replacement of the LP hose 4 Using a n open end wrench turn the inlet fitting counter clockwise to loosen and unscrew it completely by hand to remove 5 Snip the plastic tie strap 21 tha...

Page 14: ...t one leg first and then the other Be careful to avoid bending or stretch ing either leg 14 Turn the air barrel over to allow the poppet 6 to drop out Us ing fingernails or a plastic tool carefully re...

Page 15: ...ave been caused by abuse or improper disas sembly If found discard it and replace with new 22 Closely inspect the condition of the exhaust valve to ensure that it is evenly seated against the second s...

Page 16: ...ecommends Christo Lube MCG 11 PN MS150 to be used ex clusively for the lubrication and dressing of O rings and other internal parts Christo Lube provides superior lubrication to that of silicone greas...

Page 17: ...spring has been discarded and replaced with new Up to three washers may be used If one is needed install between the spring and body If two are needed install on opposite sides of spring If three are...

Page 18: ...s cold or silty water do not install the collar at this time Refer to the instructions provided at the end of this procedure for installing the IceBreaker environmental sealing collar 15 Gently mate t...

Page 19: ...nto the inlet port of the body Tighten the yoke retainer clockwise by hand until finger snug d Apply a torque wrench with the 1 Yoke Nut Socket and 3 xa Socket Drive Extension available from Peter Bui...

Page 20: ...do will seriously af fect the regulator s performance and could result in serious injury or death 1 Using a narrow tipped oral syringe slowly inject silicone grease through the ports on all sides of t...

Page 21: ...gs are rounded on one side and flat on the other See Fig 23 Hold the air barrel with the flat cut facing down and place the clip over the tube with the rounded side facing toward the flange so that on...

Page 22: ...de up with the front facing you slide the valve assembly into the opening in the right side of the housing Gently depress the lever and then slide the valve assembly through the opening on the inlet s...

Page 23: ...tly over the lever with its raised surface facing up and then the thrust washer 15 19 Fit the front cover 16 inside the housing so that it seats directly over the diaphragm Turn it as needed to align...

Page 24: ...bled and properly adjusted second stage is connected to the first stage before pressurizing Failure to relieve inter mediate pressure that exceeds 400 psi may result in damage or rupture of the test g...

Page 25: ...Fig 37 2 Mate the female fitting of the LP hose onto the male fitting of the IP Test Gauge and tighten the swivel nut clockwise until finger snug 3 Install the LP hose into an intermediate pressure p...

Page 26: ...and verify that a slight leak of airflow is present 2 Slowly turn the adjustment knob clockwise to verify that the airflow stops between 2 1 turn 3 Turn the adjustment knob completely in clockwise to...

Page 27: ...e problem s NOTE The location of extremely small leaks can best be detected by applying a soap solution to the leak area Before disassembling to correct any leaks rinse the entire regulator thoroughly...

Page 28: ...d 3 Replace filter with new 4 Low intermediate pressure 4 See below 1 Piston cap is loose 1 Tighten piston cap 2 Main valve spring is damaged 2 Replace spring and spring washers 3 Incorrect number of...

Page 29: ...fice incorrectly adjusted 3 Reset to preliminary setting and readjust 3 Lever is damaged 3 Replace with new 1 Lever is slack or orifice incorrectly adjusted 1 Reset to preliminary settings and readjus...

Page 30: ......

Page 31: ......

Reviews: