Waterproof tester series 

1

 

DATA SHEET 

 

 

pH 1 

COND 1 

pH 5 / 

pH 5 Food 

ORP 5 

COND 5 

PC 5 

pH

 Range  

0…14

 

-

2…16

 

-

2…16

 

Resolution / Accuracy 

0.1 / 

+0.1 

0.01 / +00.1 

0.01 / +0.1 

MultiPoint Calibration 

1…2

 

1…3

 

1…3

 

Buffer Value 

3 buffers 

USA 

5 buffers USA 

5 buffers USA 

mV 

Range

 

+1000 

+1000 

Resolution  

0.1 / 1 

0.1 / 1 

COND

 Range  

0…2000µS / 

0…20mS

 

0…200µS / 0…2000µS / 0…20mS

 

 

Resolution / Accuracy 

Automatic 

scale / +1% f.s. 

Automatic scale / +1% f.s. 

 

MultiPoint Calibration 

1…2

 

1…3

 

Temperature 
compensation

 

1.9 %/°C 

0.00…4.00%/°C

 

Reference temperature 

25 °C 

20/25 °C 

TDS 

Range  

0.1ppm…

10ppt 

0.1ppm…10ppt

 

TDS factor 

0.40…1.00

 

0.40…1.00

 

Salinity 

Range  

0.01…10 g/L

 

Temperature 

Range  

0…50°C (n.v)

 

0…50°C

 

0…50°C 

(n.v) 

0…50°C

 

Resolution / Accuracy 

0.1 / +0.2°C 

0.1 / +0.2°C 

Temperature unit 

°C/°F 

°C/°F 

Device

 

 

Indication buffers 

used for calibration 

Yes 

Yes 

Auto power-off 

8 min 

 

Display 

LCD 

 

LCD backlight 3 colors 

 

IP Protection 

IP 67 

Power Supply 

4X1.5V battery AAA 

Summary of Contents for 1-5 Series

Page 1: ...Version 1 0 _ March 2016 Waterproof tester series Version 1 0 _ March 2016 INSTRUCTION MANUAL TESTER SERIES 1 5...

Page 2: ...WER OFF 5 SETUP MENU for pH1 Cond1 5 MEASUREMENT 5 CALIBRATION PROCEDURE FOR CONDUCTIVITY Cond1 6 CALIBRATION PROCEDURE FOR TDS Cond1 6 CALIBRATION PROCEDURE FOR pH pH1 6 INSTRUCTIONS FOR pH5 Cond5 PC...

Page 3: ...tion Accuracy Automatic scale 1 f s Automatic scale 1 f s MultiPoint Calibration 1 2 1 3 Temperature compensation 1 9 C 0 00 4 00 C Reference temperature 25 C 20 25 C TDS Range 0 1ppm 10ppt 0 1ppm 10p...

Page 4: ...ith fixed sensor and only two keys for all functions Tester series 5 is advanced version with replaceable sensor multicolour backlight display and 3 key for all functions SAFETY INSTRUCTIONS Read this...

Page 5: ...Cond TDS SAL During Setup Press to scroll in the menu or increase the value of the selected parameter CAL During measurement press to start the calibration of the selected parameter Press to confirm t...

Page 6: ...00 pH 1413 uS High 10 01 pH 12 88 mS First point for pH calibration is always 7 00 pH POWER SUPPLY This tester series works with 4 x AAA Alkaline or NiMH rechargeable batteries Make sure the batterie...

Page 7: ...then the display will show TDS Fct flashing press to change this factor and then press to confirm Only for Cond1 5 The display will show rSt RESET nO flashing 6 Press and select YES if a reset of the...

Page 8: ...TDS with 1 or 2 points The calibration procedure for TDS is same as for Conductivity CALIBRATION PROCEDURE FOR pH pH1 1 Power ON the meter by pressing the Key 2 Rinse the electrode with distilled wat...

Page 9: ...cted parameter 5 The value of selected parameter will start flashing 6 Press to change the value and then press to confirm 7 The value stops flashing 8 Press to select other parameters or press ESC to...

Page 10: ...pH5 PC5 1 Power ON the meter by pressing the Key 2 Rinse the electrode with distilled water 3 Immerse the electrode in the 1st buffer solution pH7 00 and wait for stability 4 Press CAL key blue backl...

Page 11: ...istiller water or sample before use For short time storage use distiller water For long time store dry pH1 pH5 pH5 Food ORP5 PC5 Rinse the probe with distiller water or sample before use Store the pro...

Page 12: ...bbles in glass bulb 2 Check whether pH buffer solution is correct 3 Replace with new pH electrode Electrode slope out of range 85 or 110 pH measuring range out of range 0 00 pH or 14 00pH 1 Series 2 0...

Reviews: