Waterproof tester series 

2

 

INTRODUCTION 

Congratulation for buying one of the most innovative and easy to use Pocket Tester. 

Pocket testers series 1 and 5 are very handy for the routine measurements in all applications where fast 
indication of measurement is required. 

These Testers are specially designed for applications like: Agriculture, water and waste water treatment, 
Hydroponics, Aquaculture, Environmental monitoring, Food and beverage manufacturing, Cooling towers, 
Printing, Education etc. 

Tester series 1 is basic one with fixed sensor and only two keys for all functions. 

Tester series 5 is advanced version with replaceable sensor, multicolour backlight display and 3 key for all 
functions. 

 

SAFETY INSTRUCTIONS 

 

Read this instruction manual carefully before using your new tester. 

 

The membrane of pH electrode is made of glass and can be danger in case it breaks. 

To avoid damage check the electrode tip after each measurements. 

 

Replace all batteries together with same type. 

 

The manufacturer of these instruments can’t be held responsible for any improper use.

 

 

Verification of the measuring results is the responsibility of the operator and the manufacturer 

doesn’t respond to any direct or indirect damage occurred while using this instrument.

 

 

 

Summary of Contents for 1-5 Series

Page 1: ...Version 1 0 _ March 2016 Waterproof tester series Version 1 0 _ March 2016 INSTRUCTION MANUAL TESTER SERIES 1 5...

Page 2: ...WER OFF 5 SETUP MENU for pH1 Cond1 5 MEASUREMENT 5 CALIBRATION PROCEDURE FOR CONDUCTIVITY Cond1 6 CALIBRATION PROCEDURE FOR TDS Cond1 6 CALIBRATION PROCEDURE FOR pH pH1 6 INSTRUCTIONS FOR pH5 Cond5 PC...

Page 3: ...tion Accuracy Automatic scale 1 f s Automatic scale 1 f s MultiPoint Calibration 1 2 1 3 Temperature compensation 1 9 C 0 00 4 00 C Reference temperature 25 C 20 25 C TDS Range 0 1ppm 10ppt 0 1ppm 10p...

Page 4: ...ith fixed sensor and only two keys for all functions Tester series 5 is advanced version with replaceable sensor multicolour backlight display and 3 key for all functions SAFETY INSTRUCTIONS Read this...

Page 5: ...Cond TDS SAL During Setup Press to scroll in the menu or increase the value of the selected parameter CAL During measurement press to start the calibration of the selected parameter Press to confirm t...

Page 6: ...00 pH 1413 uS High 10 01 pH 12 88 mS First point for pH calibration is always 7 00 pH POWER SUPPLY This tester series works with 4 x AAA Alkaline or NiMH rechargeable batteries Make sure the batterie...

Page 7: ...then the display will show TDS Fct flashing press to change this factor and then press to confirm Only for Cond1 5 The display will show rSt RESET nO flashing 6 Press and select YES if a reset of the...

Page 8: ...TDS with 1 or 2 points The calibration procedure for TDS is same as for Conductivity CALIBRATION PROCEDURE FOR pH pH1 1 Power ON the meter by pressing the Key 2 Rinse the electrode with distilled wat...

Page 9: ...cted parameter 5 The value of selected parameter will start flashing 6 Press to change the value and then press to confirm 7 The value stops flashing 8 Press to select other parameters or press ESC to...

Page 10: ...pH5 PC5 1 Power ON the meter by pressing the Key 2 Rinse the electrode with distilled water 3 Immerse the electrode in the 1st buffer solution pH7 00 and wait for stability 4 Press CAL key blue backl...

Page 11: ...istiller water or sample before use For short time storage use distiller water For long time store dry pH1 pH5 pH5 Food ORP5 PC5 Rinse the probe with distiller water or sample before use Store the pro...

Page 12: ...bbles in glass bulb 2 Check whether pH buffer solution is correct 3 Replace with new pH electrode Electrode slope out of range 85 or 110 pH measuring range out of range 0 00 pH or 14 00pH 1 Series 2 0...