NB These symbols on your device mean:
•  This appliance is filled with Propane gas R290. Follow strictly the manufacturer’s instruction concerning 

use and repairs!

•  Before using this appliance, you must carefully read the entire instruction manual.
•  Do not install, operate or store the device in a room with a floor area smaller than 7m

2

 for 16L/20L 

models.

•  Repairs must be performed based on the recommendations from the manufacturing company.

 
SPECIFIC SAFETY NOTES RELATING TO REFRIGERANT R290:

•  ENVIRONMENTAL INFORMATION: This unit contains fluorinated greenhouse gas covered by the 

Kyoto Protocol.

•  This appliance contains the refrigerant R290.  
•  R290 is a refrigerant that complies with European ecological standards; nevertheless, it is recommended 

not to pierce the cooling circuit of the machine. At the end of its useful life, deliver the appliance to a 

special waste collection centre for disposal. 

•  GWP (Global Warming Potential) R290 = 3.
•  If the appliance is installed, operated or stored in a non-ventilated area, the room must be designed to 

prevent the accumulation of refrigerant leaks resulting in a risk of fire or explosion due to ignition of the 

refrigerant caused by electric heaters, stoves, or other sources of ignition.

•  When defrosting and cleaning the appliance, do not use any tools other than those recommended by the 

manufacturing company.

•  The appliance must be placed in an area without any continuous sources of ignition (for example:  

open flames, gas or electrical appliances in operation).

•  Do not pierce or burn any of the components of the cooling circuit of the unit.   

Do not set light to the unit.

•  The appliance must be stored in such a way as to prevent mechanical failure or damage.
•  Appliance must be installed, operated and stored in a room with a floor area larger than 4m

2

 for 10L/12L 

models, Approximate room size 2m x 2m, and 7m

2

 for 14L models. Approximate room size 2.6m x 2.6m. 

•  Be aware that the refrigerant gases may be odourless, which means you cannot smell leaks.
•  Compliance with national gas regulations must be observed.
•  Individuals who operate or work on the refrigerant circuit must have the appropriate certification issued 

by an accredited organisation that ensures competence in handling refrigerants according to a specific 

evaluation recognised by national associations in the industry.

•  Maintenance and repairs that require the assistance of other qualified personnel must be performed 

under the supervision of an individual specifically qualified in the use of flammable refrigerants.  

Keep ventilation openings clear of obstruction.

2

Summary of Contents for XPDH16T

Page 1: ...ls XPDH16T 20T These products fully comply with all current European Safety Standard requirements for Dehumidifiers and are fully compliant with the Low Voltage Directive 2014 35 EU the EMC Directive...

Page 2: ...ers stoves or other sources of ignition When defrosting and cleaning the appliance do not use any tools other than those recommended by the manufacturing company The appliance must be placed in an are...

Page 3: ...Please ask a professional service agent to repair the product Improper repair may cause danger to users Disconnect the appliance from mains power whenever it is not in use before relocating it and bef...

Page 4: ...appliance is not in use microorganisms can grow in stagnant water the water tank should be emptied and cleaned regularly and properly Empty the tank clean and dry it when not in use and before puttin...

Page 5: ...or insert any object into any openings Do not use the appliance in locations where paint petrol or other flammable liquids are used or stored Do not use bug sprays or other flammable cleansers vapour...

Page 6: ...xtension lead may become overload Where there is risk of fire or close to a naked flame Where the power cable may be damaged On a slope or uneven surface Where it may be damaged by chemicals If there...

Page 7: ...Maximum Suction Pressure MPa 0 85MPa 0 85MPa Maximum Discharge Pressure MPa 2 2MPa 2 2MPa Maximum Pressure of Coil MPa 9 6MPa 9 6MPa Refrigerant R290 GWP 3 Refrigerant Charge kg 0 060kg 0 070kg CO2 E...

Page 8: ...ease ensure unit has settled for 12 hours 2 Please remove carbon filter from its bag and locate between the anti dust filter and air inlet on the body of the product make sure carbon filter is lined u...

Page 9: ...an begin by positioning the dehumidifier close to this area and later moving it to a more central point When positioning the dehumidifier ensure that it is placed on a level surface and that there is...

Page 10: ...ton selected models 6 AIR CLEAN indicator 7 DRYER indicator 8 DRYER High fan speed setting 9 High ventilation indicator 10 Speed Ventilation selection button 11 Low fan speed setting 12 Power indicato...

Page 11: ...ant to circulate the air or to help remove an odour from a room please press AIR CLEAN button which will disengage the dehumidifier function and operate the product as an air circulating filter only S...

Page 12: ...rated at very high humidity levels the water tank will require more frequent emptying In this situation it may be more convenient to set the unit up for continuous drainage this can be done as follows...

Page 13: ...o help re charge the active carbon properties WASHING THE PLASTIC DUST FILTER Remove the anti dust filter and separate the active carbon filter not washable and set it aside carefully Use a vacuum cle...

Page 14: ...HE UNIT SEEMS TO DO LITTLE Are too many windows or doors open Is there something in the room producing lots of humidity THE UNIT IS TOO NOISY Check whether the unit is sitting on a level surface THE U...

Page 15: ...o any charges before any chargeable service is carried out What is not covered by a Xpelair Guarantee The Xpelair guarantee does not cover any of the following Any fault or damage to your Xpelair prod...

Page 16: ...work under the Xpelair guarantee will be carried out by Xpelair or its authorised dealer s and any parts that are replaced will become the property of Xpelair Any repairs performed under the Xpelair...

Reviews: