Light Level Sensor

A Light Level Sensor is included to prevent the fan from switching automatically to boost at night-time. This is a useful
feature particularly if the Heat Recovery Ventilator is installed in a bedroom or bed-sit accommodation, ensuring noise
is kept to a minimum.

The sensor is factory set in the OFF position as this is preferred for most installations. This means that the automatic
boost feature will operate if the humidity rises during the hours of darkness. To activate the Light Sensing feature, (boost
inhibited during darkness) turn the adjuster fully anti-clockwise, shown on page 2.

This should be an approximate setting for most installations depending on the location of the remote
transformer/humidity assembly in the room.

Fine tuning may be required for precise operation:-

Clockwise allows boost to operate during darkness
Anti-clockwise prevents boost operating during darkness

A simple test for the correct setting is to trigger the boost feature via the humidity sensor in a darkened room. When
switching the light on or off, the boost speed should cut in and out accordingly.

Cleaning

1.

Before cleaning isolate the Sensor completely from the mains electrical supply.

2. 

Wipe the cover carefully with a damp cloth.

3. 

Dry throughly with a soft cloth
Do not immerse Sensor in water or other liquids.

If required, a cleaning service is available from 

GDA Applied Energy Limited Customer Service Department (UK only)

Never use strong solvents to clean the Sensor.

A part from cleaning, no other maintenance is required. 

Eclipse - Oxplaire  12/4/00  6:51 pm  Page 9

Summary of Contents for XHR150PC

Page 1: ...educe dust mite eliminate mould growth or dampness and condensation and to provide warmed fresh air April 2000 These appliances are intended for connection to fixed wiring Check that the electrical ra...

Page 2: ...an be adjusted by turning the thumbwheel as shown on page 2 We recommend that it is initially set to number 6 on the scale which is suitable for most locations Turning the thumbwheel clockwise decreas...

Page 3: ...ric Requirements of all authorities concerned must be observed for exhaust air discharge and intake flow rates a Survey the property carefully and identify the best site for the ventilator Condensatio...

Page 4: ...masonary does not fall injure people or damage property below e Measure the length of the hole between the outside brick face and inner plaster work Now cut the outer tube accurately to the required l...

Page 5: ...ive gently against the wall compressing the adhesive Then pull the tube into the room leaving the finisher in place Ensure that the finisher does not fall v Now manipulate the finisher to expand it ou...

Page 6: ...or in the direction you have determined for the transformer or remote control Fit screw plugs into the screw holes l Fit the wall plate onto the open end of the large tube fitted with the outside cowl...

Page 7: ...ble isolating switch with a minimum contact gap of 3mm wall or ceiling mounted If metal switch boxes are used earthing regulations must be following Suitably rated 2 core cable 3 mm electricians screw...

Page 8: ...wn on page 1 being extinguished p After the system has run for some time check the fan unit switches to boost by directing steam from a kettle over the remote control unit q The fan s continuous trick...

Page 9: ...depending on the location of the remote transformer humidity assembly in the room Fine tuning may be required for precise operation Clockwise allows boost to operate during darkness Anti clockwise pr...

Page 10: ...and service Customers outside UK see International below UK Xpelair have a comprehensive range of services including Free technical advice from Engineers on all aspects of ventilation Free design ser...

Reviews: