n)
Follow the line diagram below to make the correct connections between the fan assembly and the
transformer/humidity sensor, and wall plate.
o)
Place the fan assembly and front cover through the wall plate and push home. Apply power to the system and
check operation. Conduct a smoke test to ensure the extract fan is running. Check that the front filters are in place
and screw the front cover to the wall plate with the screws provided.
NOTE:
If the fan unit has automatically switched to boost due to high humidity in the room, the pull cord switch
will have no effect until the humidity drops below the present level:
IMPORTANT:
The pull cord manually switches the fan unit from trickle to boost. This is confirmed by the LED
warning light shown on page 1 being extinguished.
p)
After the system has run for some time, check the fan unit switches to boost by directing steam from a kettle over
the remote control unit.
q)
The fan’s continuous trickle speed has been factory set. However, if it is found that the fan is audible at this
setting, it is possible to reduce the trickle speed still further. Remove the lid of the control box, and move the fuse
link from
fast
trickle to
slow
trickle position (see diagram below). Always replace the fuse with one of the correct
type and rating.
Transformer/Humidity Sensor Unit Wiring
The fused spur and Remote Control Unit
must
be
mounted out of reach of anyone using a bath
or a shower.
TRANSFORMER UNIT
FAN ASSEMBLY
WALL PLATE
L N
DOUBLE POLE SWITCHED
AND FUSED SPUR
WITH
MINIMUM 3mm
SEPARATION ON BOTH POLES
240V 3 AMPS
240v AC
N
L
TWO
FUSE
POSITIONS
TRANSFORMER
MAINS INPUT
LOW VOLTAGE OUTPUT
SLOW TRICKLE
FAST TRICKLE
1
2
8
DO NOT
CONNECT
1 2 3