Location of the Transformer Unit

1.

Check that the electrical rating shown on the inside of the product matches the  main supply

2.

Check there are no buried pipes or cables e.g. Electricity, gas, water behind the  switch location 

(in wall or above the ceiling)

3.

Isolate the mains supply

The Transformer may be mounted on the wall or ceiling.                               

Position the transformer/humidity unit at least 6” (150mm) from a corner to allow correct airflow over the

humidity sensor. Also, ensure the humidity sensor unit is not directly in the stream of the fresh air coming in from

the fan unit, as this will result in false sensing.

An ideal location is on the same wall, or one immediately adjacent which is in the stream of the stale/damp air

being drawn into the side vents of the fan assembly.

Wiring
IF IN DOUBT CONSULT A QUALIFIED ELECTRICIAN

For fixed wiring circuits the protective fuse for the appliance must not exceed 3A.

A double isolating switch with a minimum contact gap of 3mm (wall or ceiling mounted).

If metal switch boxes are used, earthing regulations must be following.

Suitably rated 2 core cable.

3 mm electricians screwdriver and No.1 or No 2 pozidrive screwdrivers.

Masonry drill, hammer & chisel (or core drill equipment if available)

Mortar to make good the hole if  required

Decide how you are going to run the wires from the transformer to the fan unit. “All wiring must be in accordance

with IEE wiring regulations”.

A 5 amp two core power cable is required  to connect the fan assembly to the remote control. 

A two core, 3 amp supply is required on the input mains connection. An earth connection is not required.

Pass the input and output wires through the cable hole in the base plate of the remote control and fasten it in

position. 

(SEE DIAGRAM ON PAGE 2) 

To comply with electrical safety regulations both input and output leads must be clamped to the unit using the

saddle clamps provided.

m)

Mains wiring for remote control and transformer:
Red or Brown wire

to live terminal

Black or Blue wire

to neutral terminal

Do not apply power to the transformer yet.

No earth is required to the ventilator in accordance with IEE wiring regulations for SELV circuits.

All wiring must be 1mm minimum, fixing securely to comply with IEE wiring regulations, if in doubt consult a

qualified electrician.

Eclipse - Oxplaire  12/4/00  6:51 pm  Page 7

Summary of Contents for XHR150PC

Page 1: ...educe dust mite eliminate mould growth or dampness and condensation and to provide warmed fresh air April 2000 These appliances are intended for connection to fixed wiring Check that the electrical ra...

Page 2: ...an be adjusted by turning the thumbwheel as shown on page 2 We recommend that it is initially set to number 6 on the scale which is suitable for most locations Turning the thumbwheel clockwise decreas...

Page 3: ...ric Requirements of all authorities concerned must be observed for exhaust air discharge and intake flow rates a Survey the property carefully and identify the best site for the ventilator Condensatio...

Page 4: ...masonary does not fall injure people or damage property below e Measure the length of the hole between the outside brick face and inner plaster work Now cut the outer tube accurately to the required l...

Page 5: ...ive gently against the wall compressing the adhesive Then pull the tube into the room leaving the finisher in place Ensure that the finisher does not fall v Now manipulate the finisher to expand it ou...

Page 6: ...or in the direction you have determined for the transformer or remote control Fit screw plugs into the screw holes l Fit the wall plate onto the open end of the large tube fitted with the outside cowl...

Page 7: ...ble isolating switch with a minimum contact gap of 3mm wall or ceiling mounted If metal switch boxes are used earthing regulations must be following Suitably rated 2 core cable 3 mm electricians screw...

Page 8: ...wn on page 1 being extinguished p After the system has run for some time check the fan unit switches to boost by directing steam from a kettle over the remote control unit q The fan s continuous trick...

Page 9: ...depending on the location of the remote transformer humidity assembly in the room Fine tuning may be required for precise operation Clockwise allows boost to operate during darkness Anti clockwise pr...

Page 10: ...and service Customers outside UK see International below UK Xpelair have a comprehensive range of services including Free technical advice from Engineers on all aspects of ventilation Free design ser...