Inside installation of the finisher ring 

Proceed as follows:

i)

Push the large tube through the hole so it extends some 50mm beyond the face of the outside wall.

ii)

Apply silicon mastic around the rear face of the split finisher – do not compress the adhesive.

ENSURE EXTERIOR BRICKWORK IS DUST FREE

iii)

Grip the finisher in your right hand, (palm uppermost) at the left hand end of the split with the adhesive side
facing you and the split at the top. Pull back the right hand end of the split along your right arm with your left
hand. Push the finisher right through the large tube and let it expand again. Don’t let go !

With your right hand, place the inner flange on the outside of the large tube. Move your fingers in an
anticlockwise direction until the finisher is pushed fully onto the tube (see below)

iv)

Then, pull the tube and finisher back towards the room making sure that the split remains at the bottom. Carefully
pull the finisher into the gap between tube and brickwork. Press the adhesive gently against the wall, compressing
the adhesive. Then pull the tube into the room leaving the finisher in place. Ensure that the finisher does not fall.

v)

Now manipulate the finisher to expand it outwards and increase it’s internal diameter as much as possible. This
will assist the re-entry of the tube. Compress the adhesive fully against the wall to hold it in position.

h)

Fit the outside cowl to your prepared length of tube using PVC adhesive such as 

Bostik PVC Pipe Weld

or

similar. Place the adhesive in an even layer around the inside diameter of  the tube at the end that you did not cut.
Place the outside louvred vent on the end of the tube and allow the glue to set before handling it again. Wipe off
any excess adhesive on the outside of the cowl.

i)

It is important for the correct operation that the smaller diameter tube is the correct length. This tube connects the
extraction fan housing to the outside cowl and separates the two air streams. The correct fitting of this tube is
critical to the efficient operation of the ventilator. To achieve this, whatever length has been cut off the outer tube,
the exact same length must be cut off the inner tube. 

5

ADHESIVE

INNER  FLANGE

Eclipse - Oxplaire  12/4/00  6:51 pm  Page 5

Summary of Contents for XHR150PC

Page 1: ...educe dust mite eliminate mould growth or dampness and condensation and to provide warmed fresh air April 2000 These appliances are intended for connection to fixed wiring Check that the electrical ra...

Page 2: ...an be adjusted by turning the thumbwheel as shown on page 2 We recommend that it is initially set to number 6 on the scale which is suitable for most locations Turning the thumbwheel clockwise decreas...

Page 3: ...ric Requirements of all authorities concerned must be observed for exhaust air discharge and intake flow rates a Survey the property carefully and identify the best site for the ventilator Condensatio...

Page 4: ...masonary does not fall injure people or damage property below e Measure the length of the hole between the outside brick face and inner plaster work Now cut the outer tube accurately to the required l...

Page 5: ...ive gently against the wall compressing the adhesive Then pull the tube into the room leaving the finisher in place Ensure that the finisher does not fall v Now manipulate the finisher to expand it ou...

Page 6: ...or in the direction you have determined for the transformer or remote control Fit screw plugs into the screw holes l Fit the wall plate onto the open end of the large tube fitted with the outside cowl...

Page 7: ...ble isolating switch with a minimum contact gap of 3mm wall or ceiling mounted If metal switch boxes are used earthing regulations must be following Suitably rated 2 core cable 3 mm electricians screw...

Page 8: ...wn on page 1 being extinguished p After the system has run for some time check the fan unit switches to boost by directing steam from a kettle over the remote control unit q The fan s continuous trick...

Page 9: ...depending on the location of the remote transformer humidity assembly in the room Fine tuning may be required for precise operation Clockwise allows boost to operate during darkness Anti clockwise pr...

Page 10: ...and service Customers outside UK see International below UK Xpelair have a comprehensive range of services including Free technical advice from Engineers on all aspects of ventilation Free design ser...

Reviews: