9
5.6 Condensate drain
A condensate drain must be fitted to run to the building waste water system in accordance with the Building
Regulation H1.
The Condensate Drain Tube is connected to the MVHR through the hole on the underside of the plastic base (fit the
end of Drain Tube with the non-slip tape around it onto the MVHR). The Condensate Drain Tube can be adapted to
the installation requirements. It is important that the Condensate Drain Tube is positioned higher than the water
surface of the water trap and that the Condensate Drain Tube ends within the water head of the water trap.
The Condensate Drain Tube should be checked annually and cleaned if necessary.
A Condensate Drain Tube (Ø 20mm and 1.0m long) is supplied with each MVHR.
The water trap must be purchased separately from a local plumbing stockist.
5.7 Installation example
Exhaust air
from the rooms
(kitchen/bathroom/toilet)
Supply air
into the building
(living rooms/bedrooms/children‟s rooms)
External air
(fresh air) with vapour diffusion-resistant insulation
Outgoing air
from inside to outside with vapour diffusion-resistant insulation