25
7.11 RF Receiver (Xcell 400 QVI model only)
Remove the cover plate on top of the MVHR to reveal two terminal blocks, pre-wired with white, blue and red cables.
Connect the terminal blocks to the RF Receiver as shown in the wiring diagram below.
Push the aerial of the RF Receiver through the grommet in the cover plate, place the RF Receiver inside the pocket
provided and re-secure the cover plate with the screws provided. Move the aerial into an upright position.
7.12 RF Transmitter (Xcell 400 QVI model only)
No wiring is required for the RF Transmitter.
Mount the RF Transmitter on the wall in each of the required rooms.
Up to six RF Transmitters can be used per MVHR.