U
SER
M
ANUAL
X
ORAYA
S
UITE
63
Setting
Description
Default
Enable
Turn on logging for this channel
On
iso
CAN FD standard
On
: ISO 11898-1
Off
: original standard by Bosch
On
Alias
Freely selectable channel name
can#
Bus ID
Additional ID for subsequent evaluation
Baudrate
Transfer rate (in bit/s)
Values: 100 k, 125 k, 200 k, 250 k, 400 k,
500 k, 666 k, 800 k, 1000 k
500 k
Protocol
Classic CAN
or
CAN-FD
Classic CAN
Baudrate (FD)
Transfer rate for the payload section of a
CAN FD message (in bit/s)
Values: 500 k, 1000 k, 2000 k
2000 k
Use Busspec
Load configuration template provided by the
vehicle manufacturer
Off
Prevent Sleep
Mode
Minilogger Z7 will not go into sleep mode as
long as there is activity on this channel
On
Wake
Minilogger Z7 wakes up from sleep mode as
soon as there is activity on this channel
On
Acknowledge/
Send
Acknowledgment and transmission capacity
Send and acknowledge
:
Minilogger Z7 operates in active mode on the
CAN bus (transmission possible,
acknowledgment of CAN messages,
generation of error frames)
passive (not send/acknowledge)
: Minilogger
Z7 operates in passive mode on the CAN bus
(receipt possible, no acknowledgment of CAN
messages, no generation of error frames)
Send but NOT acknowledge
:
Minilogger Z7 operates in semi-passive mode
on the CAN bus (transmission possible, no
acknowledgment of CAN messages, no
generation of error frames)
passive
(not send/
acknowledge)
autoacknowledge
self transmitted
message
Messages sent by the Minilogger Z7 are
automatically acknowledged
Off