6
Part Number
18141, F, 11/06/2017
Installation
Installing the Display Unit (G1BR-B01-D/G1CR-B01-D or G2BS-B01-D)
The Display Unit should be located at the instrument panel, so that the visible and
audible indicators may be easily observed.
Drill a 2-1/16” hole to accommodate the G1BR-B01-D/G1CR-B01-D Display Unit.
Drill a 2-1/8” hole to accommodate the G2BS-B01-D Display Unit.
Insert Display Unit into hole and secure with the provided threaded mounting nut.
NOTE
DO NOT MAKE ELECTRICAL CONNECTIONS AT THIS TIME. THEY WILL BE ADDRESSED IN A LATER
SECTION.
Routing Sensor Cable(s) (FS-X01 CABLE XX’)
A 20 FT Sensor Cable is provided for each Gasoline Fume Sensor. The Sensor Cables
should be routed starting at the Display Unit, then to the pre-determined location of the
Gasoline Fume Sensor. Connect to the Display Unit using the attached quick-disconnect
connectors. Take care not to pinch, break, or cut the Sensor Cable or put too much
stress on the connectors while routing the cable. Secure the Sensor Cable with the
appropriate hardware for the application.
NOTE
DO NOT CUT EXTENSION CABLE FOR ANY PURPOSE. DOING SO VOIDS THE PRODUCTS
WARRANTY. LONGER CABLES ARE AVAILABLE FROM 20 FT TO 100 FT.
Installing Gasoline Fume Sensor(s) (FS-T01)
The Gasoline Fume Sensor should be located in the Bilge, just above the “Slosh Line”. A
good rule of thumb is to install no lower than the height of the starter solenoid. Avoid
locating sensors near manifold or exhaust systems, as high heat may damage the
sensor.
Use the appropriate #8 mounting hardware to mount the Gasoline Fume Sensor in the
desired location. The rubber gasket should be installed between the sensor and the
mounting surface.
Connect to the Extension Cable using the attached quick-disconnect connectors.