background image

Part Number

 

18141, F, 11/06/2017

 

 

 

Additional copies of this manual are available at no charge by contacting the manufacturer, 

distributor or dealer.  Fireboy-Xintex reserves the right to change features without notice.  
 
 
 

General Information 

  

  

  

Specifications 

  

  

  

Operation of Xintex Gasoline Fume Detector(s) 

  

  

  

Installation 

 

Installing the Display Unit (G1BR-B01-D/G1CR-B01-D or G2BS-B01-D) 

 

Routing Sensor Cable(s) (FS-X01 CABLE XX’) 

 

Installing Gasoline Fume Sensor(s) (FS-T01)

 

 

Electrical Connections (G1BR-B01-D/G1CR-B01-D or G2BS-B01-D) 

 

 

Testing the System Operation 

 

 

Testing the Gasoline Fume Sensors 

 

 

 

Maintenance 

 

 

 

In the Event of an Alarm 

 

 

 

Repairing Xintex Gasoline Detection Components 

  

  

  

Returning Xintex Gasoline Detection Components 

  

  

  

1 Year Limited Warranty 

10 

 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for G-1BB-R

Page 1: ...nnel Systems G 1BB R Black Round Blower Control G 1CB R Chrome Round Blower Control Dual Channel System G 2BB R Black Square Blower Control Owner s Manual Installation Instructions Read and comply with all instructions warnings and limitations before installing servicing or removing this device ...

Page 2: ...ine Fume Detector s 4 Installation 7 Installing the Display Unit G1BR B01 D G1CR B01 D or G2BS B01 D 7 Routing Sensor Cable s FS X01 CABLE XX 7 Installing Gasoline Fume Sensor s FS T01 7 Electrical Connections G1BR B01 D G1CR B01 D or G2BS B01 D 8 Testing the System Operation 8 Testing the Gasoline Fume Sensors 8 Maintenance 9 In the Event of an Alarm 9 Repairing Xintex Gasoline Detection Componen...

Page 3: ...dition these units automatically actuate your bilge Blower to purge the space of fumes The systems use sensors located in a place of interest and a central display unit that notifies you of the state of the system Specification System Specifications G 1BB R G 1CB R Operating Voltage 9 30 VDC Nominal Current Draw 55mA 12 VDC Maximum Current Draw 95mA 9 VDC Maximum Blower Output Current 2A Operating...

Page 4: ...l The Red LED located at the bottom indicates a fume buildup of 20 of the LEL Lower Explosive Limit which is considered an alarm The Blower status LED and alarm horn will actuate when the Red LED is illuminated Whenever the Blower status LED is illuminated the Blower is active The alarm status will continue as long as the fume level remains at an elevated level The alarm horn may be silenced by pr...

Page 5: ...ound Blower Switch YELLOW Switching Ground 2A Fuse Included 12 VDC from Blower Circuit Breaker MB30RLY 30 86 87 85 G1BR B01 D G1CR B01 D FS X01 CABLE XX FS T01 RED Power 1 0 Amp Fuse from Circuit Breaker BLACK Ground Blower Ground YELLOW Switching Ground 2A Fuse Included 12 VDC from Blower Circuit Breaker MB30RLY 30 86 87 85 Blower Switch ...

Page 6: ...ume Sensor Connect to the Display Unit using the attached quick disconnect connectors Take care not to pinch break or cut the Sensor Cable or put too much stress on the connectors while routing the cable Secure the Sensor Cable with the appropriate hardware for the application NOTE DO NOT CUT EXTENSION CABLE FOR ANY PURPOSE DOING SO VOIDS THE PRODUCTS WARRANTY LONGER CABLES ARE AVAILABLE FROM 20 F...

Page 7: ...tors can be tested by pressing the Check Reset button on the face of the Display Unit The Display Unit will cycle through the LEDs and the alarm horn will activate while the LEDs cycle Unplug the Gasoline Fume Sensor from each channel of the Detection System one at a time The Yellow Fault LED should illuminate If the Yellow LED does not illuminate remove Display Unit and return direct to manufactu...

Page 8: ...y and make any necessary repairs Repairing Xintex Gasoline Fume Detection Components Xintex Gasoline Fume Detection Components are not field serviceable Components must be returned to the factory for any repairs Returning Xintex Gasoline Detection Components No product may be returned for credit or repair without a written Returned Material Authorization RMA form Purchaser must call or email Fireb...

Page 9: ...ment of Fireboy Xintex LLC does not assume the costs of removal and or installation of the product or any other incidental costs of removal and or installation of the product or any other incidental costs which may arise as a result of any defect in material or workmanship and e upon discovery of defect Buyer shall immediately cease use of and notify Fireboy Xintex LLC Any warranty implied by law ...

Reviews: