Operation of Xintex Gasoline Fume Detector(s)
There are 3 LEDs located on the Display Unit for each channel on the system, as well as an LED for
the Blower status. The Green LED, located at the top, indicates that the system is operational.
The Yellow LED, located in the center, indicates that there is a Fault in the system. This is to notify
the user to check the connections and wire runs of the sensors. There may be a break in the
wiring or a disconnected sensor on that channel. The Red LED, located at the bottom, indicates a
fume buildup of 20% of the LEL (Lower Explosive Limit) which is considered an alarm. The Blower
status LED and alarm horn will actuate when the Red LED is illuminated. Whenever the Blower
status LED is illuminated, the Blower is active.
The alarm status will continue as long as the fume level remains at an elevated level. The alarm
horn may be silenced by pressing the “Check/Reset” button, but the Blower will remain active
until the alarm status has ended. The alarm will reactivate after 30 seconds as long as the
Detector remains in alarm status. The problem should never be considered corrected as long as
the Red LED is illuminated.