![Xinje DS2-20P7-AS User Manual Download Page 36](http://html1.mh-extra.com/html/xinje/ds2-20p7-as/ds2-20p7-as_user-manual_3448033036.webp)
34
07
T-REF distribution
0: undefined.
1: T-REF is external torque limit input.
2: undefined.
3: P-CL, N-CL is ON, T-REF is
external torque limit input.
-
0
0
~
3
○
08
V-REF distribution
0: undefined.
1: V-REF external speed limit input.
-
0
0
、
1
○
2. Control parameter P1(address: 0100
~
01FF)
P1-
Name
Unit
Default
value
Range
Effective
time
00
Speed loop gain
1Hz
100
1
~
5000
√
01
Speed loop integral time
0.1ms
400
1
~
50000
√
02
Position loop gain
1/s
100
1
~
2000
√
03
Reserved
04
Second speed loop gain
1Hz
250
1
~
5000
√
05
Second speed loop integral
time
0.1ms
10000
1
~
50000
√
06
Second position loop gain
1/s
250
1
~
2000
√
07
Reserved
08
Reserved
09
Position loop feed forward
gain
1%
0
0
~
100
√
10
Feed forward filter time
0.01ms
0
0~65535
√