Event
The Event tabs describe how and when the unit will perform certain actions. Alarm In, Manual
Trigger and VMD may be set up as alarm sources. Event Out is often set up to upload images,
send email and activate output ports. Many event actions require an Event server for their function.
This server is used to receive uploaded Motion JPEG images.
NOTE
The VMD for Stream2 (MJPEG) do not support.
Event In – Alarm In
This page allows you to configure the 2 inputs supported by the camera. Ports can be given as
Normally Open or Normally Close state, and their Normal state can be configured.
An input will be inactive as long as its Normal state equals its Current state. The 2 options for
Normal state are NO (Normally Open) and NC (Normally Close). The input is activated when the
Current state changes so that it no longer equals the Normal state.
Figure 32. Event / Event In – Alarm In
Alarm In Port 1 Setting:
Click the Enable alarm in port1 checkbox to enable the Alarm In
port 1.
Type:
The default setting is NO.
-- NO:
Normally Open