Uploading the Firmware
Using the TFTP utility you are able to update the firmware on the Twin WAN Gateway.
This is useful when you also need to recover the Gateway from a configuration failure.
To upload firmware to the Twin WAN Gateway:
1.
Open the TFTP utility by double clicking on the TFTP executable file (tftp.exe).
2.
Enter the Gateways IP address (Default is: 192.168.1.1)
3.
Enter a file name that you would like to save the file as (Example: config-
file.bin).
4.
Click the Download button. It could take up to 1 to 3 minutes to upload the
firmware. The Gateway will reboot thereafter.
Example of uploading a firmware into the Twin WAN Gateway.
Note:
If you are currently using Firmware Release 23 or earlier, you will first need to update to Version
27. Upon the successful upload of Version 27, you may then upload to the latest firmware.
Omitting this procedure will result with PID mismatch error message. This applies to all models
of the Twin WAN Series.