How to Use

Connecting to power: Plug the humidifier into an electrical outlet that meets the humidifier's requirements. When the 
humidifier makes a beep, it is in standby mode.
Turning on/off: Press the power button to turn on/off the humidifier. When turned on for the first time, the humidifier is at 
level 1 by default.
Switching the mode: Press the mode button to cycle through the modes of level 1, level 2, level 3, and constant humidity, 
and the corresponding indicator will remain white. After the humidifier is turned off and turned back on again, the mode will 
be the last used one.

Constant humidity mode (recommended): This mode will maintain humidity at 60% RH by default. If the current humidity 
does not reach 60% RH, the humidifier will switch to level 3. When the ambient humidity reaches 60% RH, the humidifier will 
automatically switch to level 1. When this mode is in use, the constant humidity indicator will remain on.
Note: It is recommended to use the constant humidity mode to prevent tables from being wet due to inappropriate mode 
settings.
UV sterilization: The humidifier has a built-in UV-C light, which is turned on simultaneously with the humidifier. After the 
humidifier is turned off, the UV-C light will turn off in two minutes.
Note: The UV-C light cover needs to be installed correctly by aligning the marks on the humidifier. Otherwise, the humidifier 
cannot work properly.
Enabling/Disabling Wi-Fi: Press the power button and the mode button simultaneously to enable or disable Wi-Fi.

Mode in operation

Insufficient water in the water tank

Water tank removed

Mode Indicator Descriptions

The indicator of the corresponding mode remains white.

The four indicators remain red for 30 seconds, then go out.

The four indicators remain red and go out after the water tank is reinstalled.

Power Button

Mode Button

Constant Humidity* Indicator 
* This mode is recommended.

Level 3 Indicator

Level 2 Indicator

Level 1 Indicator

Summary of Contents for mi Smart Humidifier 2

Page 1: ...Smart Humidifier 2 User Manual ...

Page 2: ...on This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified ...

Page 3: ... day Before refilling clean it with fresh tap water or cleaning agents if required by the manufacturer Remove any scale deposits or film that has formed on the sides of the water tank or on interior surfaces and wipe all surfaces dry WARNING Micro organisms that may be present in the water or in the environment where the appliance is used or stored can grow in the reservoir and be blown in the air...

Page 4: ...conduits or any components inside the reservoir Unplug the humidifier during thunderstorms or when you do not plan to use it for an extended period of time Do not turn the humidifier upside down when it is working or there is water in the tank so as to avoid damage to the internal electronic components Do not add essential oils to any parts of the humidifier other than the essential oil compartmen...

Page 5: ...ential oil only add essential oil here Press to open Interior View of the Water Tank Interior View of the Base Filter with filter sponge inside Water Conduits Floater Floating Board Vaporizer Do not pour water along the side with buttons Non directWater Adding Area Power Cord Note Illustrations of product accessories and user interface in the user manual are for reference purposes only Actual prod...

Page 6: ...open the water tank cover and add water directly without removing the water tank Make sure that the water tank and the base are placed steadily on a level surface during water adding Do not splash water on the mist outlets during water adding to avoid water leakage Notes How to Install Maximum Water Level Mark Water Tank Base 2 Put an appropriate amount of essential oil sold separately onto the fi...

Page 7: ...ode is in use the constant humidity indicator will remain on Note It is recommended to use the constant humidity mode to prevent tables from being wet due to inappropriate mode settings UV sterilization The humidifier has a built in UV C light which is turned on simultaneously with the humidifier After the humidifier is turned off the UV C light will turn off in two minutes Note The UV C light cov...

Page 8: ...dicators will go out and the humidifier will enter standby mode Press the power button to turn the humidifier on Over humidity protection When operating at level 3 the humidifier will automatically switch to level 1 if it detects that the ambient humidity exceeds 70 RH for 30 minutes This function can prevent tables from being wet by a large amount of moisture Note This function is disabled by def...

Page 9: ...u can pour citric acid sold separately into the tank wipe off the scale with a cotton swab or soft brush and then clean the tank with water If the humidifier will not be used for an extended period empty the water tank but do not pour water along the side with buttons Then clean and dry all the parts before storing the humidifier It is recommended to replace the fiber cotton in the essential oil c...

Page 10: ...amaging the humidifier Do not use the humidifier in environments where the temperature is below 0 C as the water in the water tank may freeze and cause damage to the humidifier Always empty the water out of the water tank in such environments Do not place any metal objects chemicals or detergent into the water tank when the humidifier is in use as this will damage the humidifier and cause air qual...

Page 11: ...Rated Frequency 50 60 Hz Operation Frequency 2400 2483 5 MHz Operating Temperature 5 C to 40 C Wireless Connectivity Wi Fi IEEE 802 11 b g n 2 4 GHz Bluetooth 4 2 Humidifying Capacity 350 mL h Noise 38 dB A Net Weight 1 57 kg Water Tank Capacity 4 5 L Item Dimensions Φ 190 335 mm Maximum Output Power 20 dBm Operating Humidity 10 80 RH Under normal use of condition this equipment should be kept a s...

Page 12: ...ducts bearing this symbol are waste electrical and electronic equipment WEEE as in directive 2012 19 EU which should not be mixed with unsorted household waste Instead you should protect human health and the environment by handing over your waste equipment to a designated collection point for the recycling of waste electrical and electronic equipment appointed by the government or local authoritie...

Page 13: ...mmunications Co Ltd Manufactured by Guangdong Deerma Technology Co Ltd a Mi Ecosystem company Address No 4 1 Longhui Road Malong Village Committee Beijiao Town Shunde District Foshan City Guangdong Province China Importer Beryko s r o Pod Vinicemi 931 2 301 00 Plzeň www beryko cz ...