About the GFX4 Digital Humidistat

In Automatic Mode the GFX4 will adjust the humidity in your home based on the outdoor temperature, lowering the humidity in cold weather to reduce 

condensation.  The GFX4 can operate in Manual Mode to control humidity to a specific relative Humidity.  In most homes, Automatic operation is preferred 

to reduce condensation on windows and within the structure.  Manual mode is necessary where the outdoor temperature sensor cannot be installed.  

Manual mode may be desirable where valuable artwork, instruments or woodwork demand constant humidity.  The GFX4 has a dry contact for fan control 

(FAN1, FAN2 terminals).  The LCD Display is backlit and easy to read.  Operation and Installation are simple.  The GFX4 can be mounted on an interior wall or 

on the return duct of the HVAC System. 

WARNING!

This Humidistat must be installed by a Qualified Technician.  Always 

TURN OFF POWER TO THE HVAC SYSTEM PRIOR TO INSTALLING OR SERVICING 

the 

Humidifier or Humidistat.  Improper operation can result in over or under humidification.  Over humidification can result in condensation, structural damage 

or mold.  Condensation within a building’s structure can cause a loss of structural strength.  Condensation can also enable mold and mildew growth resulting 

in personal injury and damage to building structure and contents.  Older and poorly insulated structures cannot withstand the same humidity levels as 

newer well insulated buildings.  Read these instructions carefully.  This humidistat requires a 24 volt, AC power supply.  Improper voltage can cause 

malfunction or damage to the control.  Do not run outdoor sensor wires on or near line voltage wires.  The technical specifications for this product and the 

contents of the user manual are subject to change without notice.

Duct Installation

Wall Installation

Outdoor Sensor Location

YES ! 

North Wall

East Wall   

Over Snow Line

Inlet of Air Intake

Less than 200’  

from humidistat.

NO! 

South Wall

West Wall   

Below Snow 

Deep in Intake

More than 200’

from humidistat.

YES!

YES!

YES!

YES!

GFX4  Locations

1” Hole.

Wall base has vents.

If wires are run inside wall,  

cut rectangular opening.  

Secure the base with the 

two plastic anchors and 

screws.

1” Hole.

Duct base: no vents. 

 

If wires are run inside duct, 

cut rectangular opening.  

Secure the base with the 

two sheet metal screws.

 

INSTALLATION AND 

OPERATING INSTRUCTIONS

!

®

Specifications

Voltage

Switching Load

Outdoor Sensor

Auto Mode

  Control Range

  Outdoor Temp.

20-30 VAC, 60Hz.

1 amp max.  30 volt 

max. 200 ft. 61m.

10%-60% RH.

-10°F, -23°C min.

 Manual Mode

   Control Range                   10%-75% RH

Accuracy -RH (77°F, 25°C) 

Accuracy Drift Per Year

Accuracy Indoor Temp.   

Accuracy Outdoor Temp.

20%-80% ±4%RH

±0.5%RH

±2°F, ±1°C

±2°F, ±1°C

Resolution, Temp. or RH 1° or 1%. 

Relay Close

Relay Open

Setting - 1%RH

S1%RH

With Furnace 

Blower Motor 

Control