background image

FusionServer G5500 V6 Server 
Technical White Paper 

A Appendix 

 

2023-02-14 

89 

 

Sensor 

Description 

Component 

Sec. Log Full 

Security log full or events 
being cleared 

Host Loss 

System monitoring 
software (BMA) link loss 
detection 

 

A.7 FAQs About Optical Modules 

The server NIC must be used with optical modules that have passed the compatibility 
test of xFusion. With uncertain transmission reliability, optical modules that have not 
been tested for compatibility may affect the service stability. xFusion is not liable for 
any problems caused by the use of optical modules that have not been tested for 
compatibility by xFusion and will not fix such problems in principle. 

When performing the compatibility tests on the optical modules used by servers, 
xFusion comprehensively verifies their functions to ensure their quality. The verified 
items include optical module plugging or unplugging, transmit and receive optical 
power, signal transmission quality, basic data reading, error tolerance, compatibility, 
electromagnetic compatibility (EMC), and environmental performance. 

Table A-7 

Problems of using optical modules that have not been tested for compatibility 

and corresponding causes 

Symptom 

Cause 

Due to non-standard 
structure and size, an 
optical module fails to be 
inserted into the optical 
interface or removed after 
being inserted. 

Structures or sizes of some optical modules that 
have not been tested for compatibility do not comply 
with the Multi-Source Agreement (MSA). When such 
an optical module is installed on an optical interface, 
the size of this optical module hinders optical module 
installation on adjacent optical interfaces. In addition, 
optical modules can be unlocked through 
self-unlocking, press-unlocking, push-unlocking, or 
tilt-unlocking. For optical modules that have not been 
tested for compatibility, the server may not be able to 
have the optical modules removed that are not 
unlocked through press-unlocking. 

Data bus defects cause the 
data bus suspension of a 
device. 

Some optical modules that have not been tested for 
compatibility have defects in data bus designs. Using 
such an optical module causes suspension of the 
connected data bus on the device. As a result, data 
on the suspended bus cannot be read. 

An optical module with 
improper edge connector 
size damages electronic 
components of the optical 
interface. 

If an optical module that has not been tested for 
compatibility with improper edge connector size is 
used on an optical interface, electronic components 
of the optical interface will be damaged by short 
circuits. 

Unnormalized temperature 

The temperature monitoring systems of some optical 

Summary of Contents for FusionServer G5500 V6

Page 1: ...FusionServer G5500 V6 Server Technical White Paper Issue 01 Date 2023 02 14 xFusion Digital Technologies Co Ltd ...

Page 2: ...t bear any liability resulting from the use of xFusion The purchased products services and features are stipulated by the contract made between xFusion and the customer All or part of the products services and features described in this document may not be within the purchase scope or the usage scope Unless otherwise specified in the contract all statements information and recommendations in this ...

Page 3: ...2 3 Ports 26 5 3 Processors 27 5 4 Memory 28 5 4 1 DDR4 Memory 28 5 4 1 1 Memory Identifier 28 5 4 1 2 Memory Subsystem Architecture 30 5 4 1 3 Memory Compatibility 31 5 4 1 4 DIMM Installation Rules 32 5 4 1 5 Memory Installation Positions 33 5 4 1 6 Memory Protection Technologies 37 5 5 Storage 37 5 5 1 Drive Configuration and Drive Numbering 37 5 5 1 1 24 x 3 5 drive configuration 20 x SAS SATA...

Page 4: ...ne 54 5 10 3 Fan Board 56 5 10 4 PSU Backplane 57 5 10 5 PCIe Switch Board 58 5 10 6 M 2 SSD Adapter Board 60 6 Product Specifications 61 6 1 Technical Specifications 61 6 2 Environmental Specifications 65 6 3 Physical Specifications 66 7 Software and Hardware Compatibility 69 8 Safety Instructions 70 8 1 Security 70 8 2 Maintenance and Warranty 73 9 System Management 74 10 Certifications 76 A App...

Page 5: ... Indicates a hazard with a high level of risk which if not avoided will result in death or serious injury Indicates a hazard with a medium level of risk which if not avoided could result in death or serious injury Indicates a hazard with a low level of risk which if not avoided could result in minor or moderate injury Indicates a potentially hazardous situation which if not avoided could result in...

Page 6: ...FusionServer G5500 V6 Server Technical White Paper About This Document 2023 02 14 vi Change History Issue Date Description 01 2023 02 14 This issue is the first official release ...

Page 7: ...erence for deep learning for scenarios such as AI HPC cloud computing and big data analysis It supports multiple types of heterogeneous processors and applies to both enterprise and public cloud deployments The G5500 V6 is a 4U GPU server that features supreme performance flexible scalability and balanced storage For details about the G5500 V6 nameplate see A 4 Nameplate Figure 1 1 G5500 V6 G5500 ...

Page 8: ...tel Virtualization Technology Intel VT allows the operating system OS to better use hardware to address virtualization workloads Intel Advanced Vector Extensions 512 Intel AVX 512 significantly accelerates floating point performance for computing intensive applications Intel DL Boost VNNI is supported to improve the performance of deep learning applications The Intel SGX and Intel TME security fea...

Page 9: ...SAS SATA drives SAS SATA drives support RAID 0 1 1E 10 5 50 6 and 60 depending on the RAID controller card used It also uses a supercapacitor to protect the RAID cache data against power failures The server provides simplified O M and efficient troubleshooting through the UID HLY indicators on the front panel fault diagnosis LED and iBMC WebUI The panel provides the iBMC direct connect management ...

Page 10: ...cure boot based on the chip RoT implements level by level firmware verification starting from the hardware RoT and builds a complete secure boot chain The trusted platform module TPM provides advanced encryption functions such as digital signatures and remote authentication The following requirements in NIST SP 800 147B are met The BIOS firmware digital signature update mechanism is supported Duri...

Page 11: ...cture Figure 3 1 Physical structure of a server with 24 x 3 5 drives example 1 PCIe switch I O board 2 GPU 3 PSUs 4 Power adapter board 5 Chassis 6 GPU beam 7 Supercapacitor 8 Air duct 9 Cable management arm CMA 10 M 2 SSD 11 PCIe RAID controller card 12 PCIe riser card 13 Intrusion sensor 14 Fan board ...

Page 12: ...23 02 14 12 15 24 x 3 5 drive backplane 16 Left mounting ear plate 17 3 5 drives 18 Fan modules 19 Right mounting ear plate 20 Fan module frame 21 CMA 22 CPU 23 CPU heat sink 24 Mainboard 25 Memory modules 26 TPM TCM 27 BMC card 28 OCP 3 0 network adapter 29 NIC riser modules ...

Page 13: ...FusionServer G5500 V6 Server Technical White Paper 4 Logic Structure 2023 02 14 13 4 Logic Structure Figure 4 1 Logic structure ...

Page 14: ...Server G5500 V6 Server Technical White Paper 4 Logic Structure 2023 02 14 14 The server supports one or two third generation Intel Xeon Scalable processors Ice Lake The server supports up to 32 memory modules ...

Page 15: ...kplanes are provided to support different local storage configurations The LBG R Platform Controller Hub PCH is integrated on the mainboard to support five USB 3 0 ports The BMC management chip integrated on the mainboard provides a video graphics array VGA port a management network port and a serial port The G5500 V6 supports multiple logical topologies cascaded and balanced topologies and can be...

Page 16: ...FusionServer G5500 V6 Server Technical White Paper 4 Logic Structure 2023 02 14 16 Figure 4 3 Cascaded topology ...

Page 17: ...cription 2023 02 14 17 5 Hardware Description 5 1 Front Panel 5 2 Rear Panel 5 3 Processors 5 4 Memory 5 5 Storage 5 6 Network 5 7 I O Expansion 5 8 PSUs 5 9 Fan Modules 5 10 Boards 5 1 Front Panel 5 1 1 Appearance 24 x 3 5 drive configuration 20 x SAS SATA 4 x NVMe ...

Page 18: ... 2023 02 14 18 Figure 5 1 Front view 1 SATA SAS drives 2 SAS SATA NVMe drives 3 Slide out label plate with an SN label 24 x 3 5 drive configuration 16 x SAS SATA 8 x NVMe Figure 5 2 Front view 1 SATA SAS drives 2 SAS SATA NVMe drives 3 Slide out label plate with an SN label ...

Page 19: ...t connect management port indicator Indicator and Button Descriptions Table 5 1 Indicators and buttons on the front panel Silkscreen Indicator and Button Description Fault diagnosis LED The device is operating properly Error code A component is faulty For details about the error codes see the FusionServer G5500 Server iBMC Alarm Handling Power button indicato r Power indicator Off The device is po...

Page 20: ...n generated on the system Blinking red at 5 Hz A critical alarm has been generated on the system Steady green The device is operating properly UID button indicato r The UID button indicator helps identify and locate a device UID indicator Off The device is not being located Blinking or steady blue The device is being located UID button You can control the UID indicator status by pressing the UID b...

Page 21: ...ected Blinking green at short intervals for 3 seconds and then off The port is disabled Steady green The terminal is connected Indicates the status when the iBMC direct connect management port connects to a USB device Blinking red at long intervals The job fails or an error is reported when the job is complete Blinking green at short intervals The job is being executed Blinking green at short inte...

Page 22: ...nd mobile phones running Android are supported To log in to the iBMC from the local PC enter https IP address of the iBMC management network port in the address box of the browser on the local PC When accessing the iBMC through a mobile phone you need to use the mobile application FusionMobile to access the iBMC For details see the FusionMobile User Guide Used to connect to a USB device NOTICE Bef...

Page 23: ...ough a direct management interface see the FusionServer G5500 Server iBMC V3 05 00 00 or Later User Guide a The VGA port and the iBMC direct connect management port cannot be used at the same time Note The number of ports varies depending on server configuration This table lists the maximum number of ports in different configurations 5 2 Rear Panel 5 2 1 Appearance Figure 5 5 Rear view 1 Slot 1 PC...

Page 24: ... BMC card a This is supported only in the pass through expansion board scenario For details about the OCP 3 0 network adapter see 5 6 1 OCP 3 0 Network Adapter The figure is for reference only The appearance may vary according to the server configuration 5 2 2 Indicators and Buttons Indicator Positions Figure 5 6 Indicators on the rear panel 1 Data transmission status indicator for the management ...

Page 25: ...wer is supplied Blinking green at 1 Hz The input is normal and the server is in the standby state The input is overvoltage or undervoltage The PSU is in deep hibernation mode Blinking green at 4 Hz The firmware is being upgraded online Steady green The input and output are normal Steady orange The input is normal but there is no output NOTE The possible causes of no output are as follows Power sup...

Page 26: ...sing the iBMC 5 2 3 Ports Port Positions Figure 5 7 Ports on the rear panel 1 Management network port 2 Serial port 3 VGA port 4 USB 3 0 ports 5 Socket for PSU 3 6 Socket for PSU 4 7 Socket for PSU 1 8 Socket for PSU 2 Port Description Table 5 4 Ports on the rear panel Name Type Quantity Description Management network port RJ45 1 iBMC management network port which is used to manage the server NOTE...

Page 27: ... 3 0 device NOTICE The maximum current is 1 3 A for an external USB device Before connecting an external USB device ensure that the USB device functions properly otherwise it may adversely impact the server The USB 3 0 port can be used to supply power to low power peripherals However the USB 3 0 port must comply with the USB specifications To run advanced peripherals such as external CD DVD drives...

Page 28: ...erver Consult your local sales representative or see OS and Parts Compatibility in the Compatibility Checker to determine the components to be used Figure 5 8 Positions of the processors 5 4 Memory 5 4 1 DDR4 Memory 5 4 1 1 Memory Identifier You can determine the memory module properties based on the label attached to the memory module ...

Page 29: ...Quad rank 8R Octal rank 3 Data width on the DRAM x4 4 bit x8 8 bit 4 Type of the memory interface PC4 DDR4 5 Maximum memory speed 2933 MT S 3200 MT S 6 Memory latency parameters CL tRCD tRP W 20 20 20 Y 21 21 21 AA 22 22 22 7 DIMM type R RDIMM L LRDIMM 8 SPD version 10 SPD version 10 SPD versions from Byte 192 to Byte 447 9 Temperature grade Extended temperature grade XT 0 C to 95 C 32 F to 203 F ...

Page 30: ... channels first If the primary memory channel is not populated the memory modules in secondary memory channel cannot be used Table 5 5 Memory channels CPU Channel DIMM CPU1 A primary DIMM000 A A DIMM001 I B primary DIMM010 B B DIMM011 J C primary DIMM020 C C DIMM021 K D primary DIMM030 D D DIMM031 L E primary DIMM040 E E DIMM041 M F primary DIMM050 F F DIMM051 N G primary DIMM060 G G DIMM061 O H p...

Page 31: ...not be used together For details about the optional components consult your local sales representative or see OS and Parts Compatibility in the Compatibility Checker The memory can be used with the third generation Intel Xeon Scalable processors Ice Lake The maximum memory capacity supported by all processor models is the same For details about the capacity type of a single memory module see OS an...

Page 32: ...200 3200 3200 2933 a The maximum number of DDR4 DIMMs is based on dual processor configuration The value is halved for a server with only one processor b DIMM per channel DPC indicates the number of memory modules per channel The information listed in this table is for reference only For details consult the local sales representative 5 4 1 4 DIMM Installation Rules Observe the following rules when...

Page 33: ...memory modules must be identical in size and organization For a multi processor configuration each processor must have a valid memory mirroring configuration Installation rules for the memory patrol mode Comply with the general installation guidelines 5 4 1 5 Memory Installation Positions A server supports up to 32 DDR4 DIMMs To maximize performance you are advised to use balanced memory configura...

Page 34: ...FusionServer G5500 V6 Server Technical White Paper 5 Hardware Description 2023 02 14 34 Figure 5 10 Memory Installation Positions ...

Page 35: ...FusionServer G5500 V6 Server Technical White Paper 5 Hardware Description 2023 02 14 35 Figure 5 11 DDR4 DIMM installation guidelines 1 processor ...

Page 36: ...FusionServer G5500 V6 Server Technical White Paper 5 Hardware Description 2023 02 14 36 Figure 5 12 DDR4 DIMM installation guidelines 2 processors ...

Page 37: ... Data Correction Single Region ADC SR Adaptive Double Device Data Correction Multiple Region ADDDC MR Partial Cache Line Sparing PCLS 5 5 Storage 5 5 1 Drive Configuration and Drive Numbering 5 5 1 1 24 x 3 5 drive configuration 20 x SAS SATA 4 x NVMe Drive Configurations Table 5 7 Drive Configurations Configuration Front Drive Drive Management Mode 24 x 3 5 drives 8 x dual width GPUs standard swi...

Page 38: ...ive Numbering The drive numbers identified by the RAID controller card vary depending on the cabling of the RAID controller card The drive numbers identified by the RAID controller card in this section are provided based on the default cabling described in Internal Cabling in the FusionServer G5500 V6 Server Maintenance and Service Guide Drive numbering of the in Table 5 7 Figure 5 13 Drive number...

Page 39: ...5 15 15 16a 16 16 17a 17 17 18 18 18 19 19 19 20 20 20 21 21 21 22a 22 22 23a 23 23 a SAS SATA NVMe drives are supported 5 5 1 2 24 x 3 5 drive configuration 16 x SAS SATA 8 x NVMe Drive Configurations Table 5 9 Drive configurations Configuration Front Drive Drive Management Mode 24 x 3 5 drives 8 x dual width GPUs standard switch model configuration Front drive 24 x 3 5 Slots 0 to 3 support only ...

Page 40: ...VMe drives in slots 16 17 22 23 CPU the NVMe drives in slots 4 5 10 11 a Currently only the 9540 8i and 9560 8i RAID controller cards are supported Consult your local sales representative or see OS and Parts Compatibility in the Compatibility Checker to determine the components to be used Drive Numbering The drive numbers identified by the RAID controller card vary depending on the cabling of the ...

Page 41: ...rive numbering Table 5 10 Drive numbering Drive number Drive Number Displayed on the iBMC WebUI Drive Number Identified by the RAID Controller Card 0 0 0 1 1 1 2 2 2 3 3 3 4a 4 4 5a 5 5 6 6 6 7 7 7 8 8 8 9 9 9 10a 10 10 11a 11 11 12 12 12 13 13 13 14 14 14 15 15 15 16a 16 16 17a 17 17 18 18 18 19 19 19 ...

Page 42: ...rive indicators Table 5 11 SAS SATA drive indicators Active Indicator Green Fault Indicator Red Blue Description Off Off The drive is not detected Steady on Off The drive is detected Blinking at 4 Hz Off Data is being read or written properly or data on the primary drive is being rebuilt Steady on Blinking blue at 4 Hz The drive is being located Blinking at 1 Hz Blinking red at 1 Hz synchronously ...

Page 43: ...ive is detected and operating properly Blinking at 4 Hz Off Data is being read from or written to the NVMe drive Steady on Blinking Blinking blue at 4 Hz The NVMe drive is being located Blinking at 1 Hz Blinking red at 1 Hz synchronously Data on the NVMe secondary drive is being rebuilt Steady on Off Red steady on The NVMe drive is faulty If the VMD function is disabled the NVMe drives support onl...

Page 44: ...resentative or see OS and Parts Compatibility in the Compatibility Checker For details about the RAID controller card see the V6 Server RAID Controller Card User Guide 5 6 Network 5 6 1 OCP 3 0 Network Adapter The OCP 3 0 network adapters provide network expansion capabilities The FlexIO slot supports an OCP 3 0 network adapter which can be configured as required For details about the optional com...

Page 45: ...Hardware Description 2023 02 14 45 When IB cards are used to build an IB network ensure that the IPoIB modes of the IB cards at both ends of the network are the same For details contact technical support 5 7 2 PCIe Slots PCIe Slots Figure 5 17 PCIe slots ...

Page 46: ...21 Configure the number of PCIe riser cards based on the number of NICs I O module 2 provides slot 26 and supports a built in PCIe card PCIe Riser Card PCIe riser card of I O module 1 It is installed in I O module 1 and provides PCIe slots 18 19 20 and 21 Figure 5 19 PCIe riser card PCIe riser card of I O module 2 Provides PCIe slot 26 in I O module 2 ...

Page 47: ... Slot PCIe Slot or Port Descripti on CPU PCIe Port No Switch PCIe Device Supporte d by the PCIe Slot or Port PCIe Riser Card Supporte d by the Rear GPU Module Slot 1 PCIe 4 0 x16a x16 b CPU1 PE3 SW 0 FHFL dual widt h Slot 3 PCIe 4 0 x16 x16 CPU 1 PE3 SW 0 FHFL dual widt h Slot 5 PCIe 4 0 x16 x16 CPU 1 PE3 SW 0 FHFL dual widt h Slot 7 PCIe 4 0 x16 x16 CPU 1 PE3 SW 0 FHFL dual widt h Slot 10 PCIe 4 ...

Page 48: ...e 4 0 x16 x8 x8 x8c CPU 1 PE 1 8 15 OCP 3 0 specificat ions FlexIO card 2 PCIe 4 0 x16 x8 CPU 2 PE 1 8 15 OCP 3 0 specificat ions FlexIO card 3 PCIe 4 0 x16 x8 CPU 2 PE 1 0 7 OCP 3 0 specificat ions a PCIe 4 0 refers to the PCIe of the fourth generation and x16 refers to the physical slot width This also applies to the content below b The x16 in brackets indicates that the link bandwidth is x16 Th...

Page 49: ...he pci utils package from the yum source and install it to make the OS support the command Windows OS After installing the pci utils package run the lspci command to obtain the B D F information of the server VMware OS The lspci command is supported by default You can directly obtain the B D F information of the server running the lspci command 5 8 PSUs The server supports a maximum of four PSUs T...

Page 50: ...gure 5 21 Positions of PSUs 5 9 Fan Modules The server supports four fan modules The fan modules are hot swappable N 1 redundancy is supported That is the server can work properly when a single fan fails The fan speed can be adjusted Fan modules of the same P N code must be used in a server ...

Page 51: ...FusionServer G5500 V6 Server Technical White Paper 5 Hardware Description 2023 02 14 51 Figure 5 22 Positions of fan modules ...

Page 52: ...erver Technical White Paper 5 Hardware Description 2023 02 14 52 5 10 Boards 5 10 1 Mainboard Figure 5 23 Mainboard 1 OCP 3 0 network adapter 3 UBC connector UBC2 3 J6054 2 OCP 3 0 network adapter 3 connector OCP3 CONN J7023 ...

Page 53: ...3 0 J6067 18 M 2 low speed signal connector M 2 MIS J61 19 NC SI connector NCSI CONN J7013 20 PCH SATA port A B connector PORT A B M 2 J7009 21 CPU 1 UBC DD connector UBCDD 1 1 J64 22 RAID controller card UBC connector UBC 1 2 J6051 23 CPU 1 UBC DD connector UBCDD 1 3 J6052 24 Fan board signal connector FAN BOARD J7022 25 Right mounting ear connector R_EAR BOARD J7012 26 CPU 1 UBC DD connector UBC...

Page 54: ...ne Front Drive Backplane The backplane is supported by all drive configurations in section 5 5 1 1 24 x 3 5 drive configuration 20 x SAS SATA 4 x NVMe Figure 5 24 24 x 3 5 drive EXP backplane 1 20 x SAS SATA 4 x NVMe 1 Low speed signal connector REAR BP0 J37 2 UBC high speed signal connector J1 3 Mini SAS HD connector REAR BP PORTA J34 4 Mini SAS HD connector REAR BP PORTB J35 5 Mini SAS HD connec...

Page 55: ... 5 5 1 2 24 x 3 5 drive configuration 16 x SAS SATA 8 x NVMe 1 Low speed signal connector REAR BP0 J37 2 UBC high speed signal connector J1 3 Mini SAS HD connector REAR BP PORTA J34 4 Mini SAS HD connector REAR BP PORTB J35 5 Mini SAS HD connector REAR BP0 1 J33 6 Low speed signal connector REAR BP1 J38 7 Low speed signal connector MAIN BOARD J40 8 UBC 4 high speed connector J5 9 Power connector 2...

Page 56: ... 5 Water detection cable leakage detection connector LIQ LEAK1 J18 6 LAAC connector LAAC3 J15 7 Fan board power 2 connector POWER CONN2 J2 8 LAAC connector LAAC2 J14 9 Water detection cable presence detection connector LIQ PRES2 J21 a 10 LAAC connector LAAC1 J13 11 Water detection cable leakage detection connector LIQ LEAK2 J20 a 12 Fan connector FAN1A J5 13 Fan connector FAN1B J7 14 Fan connector...

Page 57: ... 19 Fan connector FAN4B J12 20 Fan connector FAN4A J10 a Reserved and unavailable currently 5 10 4 PSU Backplane Figure 5 27 PSU backplane 1 Power connector HDD BP J100 2 Power connector RSW 2 MB J102 3 Power connector RSW 1 RISER J101 4 Guide sleeve J108 5 Spurious signal connector J103 ...

Page 58: ...ector PCIE SLOT14 X16 J17 3 CEM connector PCIE SLOT12 X16 J16 4 CEM connector PCIE SLOT10 X16 J15 5 Power connector PWR CON1 J121 6 Power connector PWR CON2 J122 7 UBCDD high speed connector UBCDD1 1 J133 8 UBCDD high speed connector UBCDD2 1 J134 9 CEM connector PCIE SLOT7 X16 J14 10 CEM connector PCIE SLOT5 X16 J13 11 CEM connector PCIE SLOT3 X16 J12 12 CEM connector PCIE SLOT1 X16 J11 ...

Page 59: ...power connector GPU PWR CONN5 J113 19 GPU power connector GPU PWR CONN7 J114 20 Low speed signal connector MISC CONN J102 21 GPU power connector GPU PWR CONN10 J115 22 Power connector BACK_RISER1 2_PWR J 119 J120 23 GPU power connector GPU PWR CONN12 J116 24 GPU power connector GPU PWR CONN14 J117 25 GPU power connector GPU PWR CONN16 J118 26 UBC high speed connector UBC5 HDDBP J141 27 UBC high sp...

Page 60: ...FusionServer G5500 V6 Server Technical White Paper 5 Hardware Description 2023 02 14 60 5 10 6 M 2 SSD Adapter Board Figure 5 29 M 2 SSD adapter board 1 Signal connector J1 2 High speed connector J2 ...

Page 61: ...ne or two processors Third generation Intel Xeon Scalable processors Ice Lake Built in memory controller and eight memory channels per processor Built in PCIe controller supporting PCIe 4 0 and 64 lanes per processor Three UPI buses between processors providing up to 11 2 GT s transmission speed per channel Up to 40 cores Max 3 6 GHz Min 1 5 MB L3 cache per core Max 270 W TDP NOTE The preceding in...

Page 62: ...ity Checker Storage Supports a variety of drive configurations For details see 5 5 1 Drive Configuration and Drive Numbering Supports two M 2 SSDs M 2 SSDs are supported for RAID configuration when the server is configured with an Avago SAS3004iMR RAID controller card NOTE The M 2 SSD is used only as a boot device for installing the OS Small capacity 32 GB or 64 GB M 2 SSDs do not support logging ...

Page 63: ...he RAID controller card supports a supercapacitor for power off protection to ensure user data security The PCIe RAID controller card occupies one PCIe slot For details about the RAID controller card see the V6 Server RAID Controller Card User Guide NOTE If the BIOS is in legacy mode the 4K drive cannot be used as the boot drive Network The OCP 3 0 network adapters provide network expansion capabi...

Page 64: ...ated on the mainboard The maximum display resolution is 1920 x 1200 at 60 Hz with 16 M colors NOTE The integrated video card can provide the maximum display resolution 1920 x 1200 only after the video card driver matching the OS version is installed Otherwise only the default resolution supported by the OS is provided If both the front and rear VGA ports are connected to monitors only the monitor ...

Page 65: ...y within one year 20 to 75 Maximum rate of humidity change 20 per hour Air volume 330 cubic feet per minute CFM Operating altitude 3050 m 10006 56 ft When the server configuration complies with ASHRAE Classes A1 and A2 and the altitude is above 900 m 2952 76 ft the highest operating temperature decreases by 1 C 1 8 F for every increase of 300 m 984 24 ft When the server configuration complies with...

Page 66: ...tion vary depending on server configuration load and ambient temperature SSDs and HDDs including NL SAS SAS and SATA cannot be preserved for a long time in the power off state Data may be lost or faults may occur if the preservation duration exceeds the specified maximum duration When drives are preserved under the storage temperature and humidity specified in the preceding table the following pre...

Page 67: ...31 in Requirements for guide rail installation L shaped guide rails apply only to xFusion cabinets Static rail kit applies to cabinets with a distance of 610 mm to 950 mm 24 02 in to 37 40 in between the front and rear mounting bars Ball bearing rail kit applies to cabinets with a distance of 609 mm to 950 mm 23 98 in to 37 40 in between the front and rear mounting bars Fully equipped weight Net w...

Page 68: ...FusionServer G5500 V6 Server Technical White Paper 6 Product Specifications 2023 02 14 68 Category Description the Power Calculator to obtain specific information ...

Page 69: ...leware software and hardware The slight differences of the application software middleware basic software and hardware may cause performance inconsistency between the application layer and test software layer If the customer has requirements on the performance of specific application software contact technical support to apply for POC tests in the pre sales phase to determine detailed software and...

Page 70: ...rs of special types of work such as electricians and operators of forklifts must be certified or authorized by the local government or authority In a household scenario operation of this device may cause wireless interference Personal Safety This device is not suitable for use in places where children may be present Only certified or authorized personnel are allowed to install device Discontinue a...

Page 71: ...rist strap and remove conductive objects such as watches and jewelry Figure 8 2 shows conductive objects that must be removed before you touch a device Figure 8 2 Removing conductive objects Figure 8 3 shows how to wear an ESD wrist strap a Put your hands into the ESD wrist strap b Fasten the strap buckle and ensure that the ESD wrist strap is in contact with your skin c Insert the ground terminal...

Page 72: ...cal cables Device Security Use the recommended power cables at all times Use power cables only for dedicated servers Do not use them for other devices Use dedicated power cables to ensure equipment and personal safety When moving a device hold the bottom of the device Do not hold the handles of the installed modules such as the PSUs fan modules drives and the mainboard Handle the device with care ...

Page 73: ...on is subject to local laws or regulations The markings on the device and the descriptions in the documentation are for reference only Table 8 1 lists the maximum weight a person is permitted to carry as stipulated by a number of organizations Table 8 1 Maximum weight carried per person Organization Weight kg lb European Committee for Standardization CEN 25 55 13 International Organization for Sta...

Page 74: ...stable running of the device The iBMC allows screenshots and videos to be created when the system breaks down facilitating cause analysis of the system breakdown The iBMC offers screen snapshots and videos simplifying routine preventive maintenance recording and auditing The fault diagnose management FDM function supports component based precise fault diagnosis facilitating component fault locatin...

Page 75: ...hronizes network time to optimize time configuration The iBMC supports domain name system DNS and Lightweight Directory Application Protocol LDAP to implement domain management and directory service Intelligent power management The power capping technology helps you easily improve deployment density The iBMC uses dynamic power saving to reduce operational expenditure OPEX License management By man...

Page 76: ...FusionServer G5500 V6 Server Technical White Paper 10 Certifications 2023 02 14 76 10 Certifications Country Region Certification Standard China CCC GB4943 1 2011 GB9254 2008 Class A GB17625 1 2012 ...

Page 77: ...ndix A 1 Chassis Label Information A 1 1 Chassis Head Label A 1 1 1 Nameplate Figure A 1 Nameplate example Table A 1 Nameplate description No Description 1 Server model For details see A 4 Nameplate 2 Device name 3 Power supply requirements 4 Vendor information 5 Certification marks ...

Page 78: ... Table A 2 Certificate description No Description 1 Order 2 No NOTE For details see Figure A 3 and Table A 3 3 QC inspector 4 Production date 5 No barcode Figure A 3 Certificate number example Table A 3 Certificate number description No Description 1 P a fixed value for this digit 2 Z a fixed value for this digit 3 Y a server ...

Page 79: ... the 1st to 9th Letters A to H indicate the 10th to 17th Letters J to N indicate the 18th to 22nd Letters P to Y indicate the 23rd to 31st 8 Hour one character Digits 0 to 9 indicate 0 00 to 9 00 Letters A to H indicate 10 00 to 17 00 Letters J to N indicate 18 00 to 22 00 Letters P to Q indicate 23 00 to 24 00 9 Serial number two characters 10 Manufacturing serial number five characters A 1 1 3 Q...

Page 80: ...de NOTE Scan the QR code to obtain technical support resources A 1 2 Chassis Internal Label Figure A 5 Chassis internal label The quick start guide is located on the inside of the chassis cover It describes how to remove the mainboard components important components of the chassis precautions and QR codes of technical resources The pictures are for reference only For details see the actual product...

Page 81: ...lide out label plate uniquely identifies a device The SN is required when you contact technical support Figure A 7 SN example Table A 5 SN description No Description 1 SN ID two characters which is 21 2 Material identification code eight digits that is processing code 3 Vendor code two digits that is the code of the processing place 4 Year and month two characters The first character indicates the...

Page 82: ... six characters 6 RoHS compliance one character Y indicates environmental friendly processing 7 Internal model that is product name A 3 Operating Temperature Limitations Table A 6 Operating temperature limitations Configuration Maximum Operating Temperature 30 86 F Maximum Operating Temperature 35 C 95 F 8 x dual width GPUs standard switch model configuration All configurations are supported The A...

Page 83: ...ature Indicator board Outlet Temp Air outlet temperature BMC card PCH Temp PCH bridge temperature Mainboard CPUN Core Rem CPU core temperature CPUN N indicates the CPU number The value is 1 or 2 CPUN DTS CPU DTS value CPUN N indicates the CPU number The value is 1 or 2 CPUN Margin CPU Margin CPUN N indicates the CPU number The value is 1 or 2 CPUN VRD Temp CPU VRD temperature Mainboard N indicates...

Page 84: ... in the power on state Mainboard CPUN VCCIN CPU VCCIN voltage Mainboard N indicates the CPU number The value is 1 or 2 CPUN VSA CPU VSA voltage Mainboard N indicates the CPU number The value is 1 or 2 CPUN P1V8 CPU P1V8 voltage Mainboard N indicates the CPU number The value is 1 or 2 CPUN VCCIO CPU VCCIO voltage Mainboard N indicates the CPU number The value is 1 or 2 CPUN VCCANA CPU VCCANA voltag...

Page 85: ...umber The value is 1 or 2 CPUN Prochot CPU Prochot CPUN N indicates the CPU number The value is 1 or 2 CPUN Status CPU status detection CPUN N indicates the CPU number The value is 1 or 2 CPUN Memory Status of the memory module corresponding to the CPU Memory module corresponding to CPU N N indicates the CPU number The value is 1 or 2 FAN2A Status Fan fault status Fan N N indicates the fan module ...

Page 86: ... Temp M 2 adapter temperature M 2 adapter card BIOBoard Temp I O board temperature I O board SW1 VDD0V8 0 8 V voltage monitoring PCIe switch board SW2 VDD0V8 SW1 VRD Temp Switch board temperature monitoring PCIe switch board SW2 VDD Temp SW1 VDD1V25 1 25 V voltage monitoring PCIe switch board SW2 VDD1V25 PS Redundancy Redundancy failure due to PSU removal PSU RAID Status RAID controller card healt...

Page 87: ... output current PSU PS Pout PSU output power PSU PS Temp Maximum internal temperature of the PSU PSU PS Inlet Temp PSU air inlet temperature PSU AreaIntrusion Listening to the unpacking action Mainboard Power Power of a PSU PSU OCP Temp OCP card chip temperature OCP 3 0 network adapter CPUN PMem Temp CPU PMem module temperature PMem memory corresponding to CPU N N indicates the CPU number The valu...

Page 88: ...r GPU GPU Temp GPU temperature GPU GPU HBM Temp HBM chip temperature of the GPU card GPU CPU Usage CPU usage N A Memory Usage Memory usage ACPI State ACPI status SysFWProgress Software processes and system startup errors System Notice Hot restart reminder and fault diagnosis program information collection System Error System suspension or restart Check the background logs SysRestart System restart...

Page 89: ...d structure and size an optical module fails to be inserted into the optical interface or removed after being inserted Structures or sizes of some optical modules that have not been tested for compatibility do not comply with the Multi Source Agreement MSA When such an optical module is installed on an optical interface the size of this optical module hinders optical module installation on adjacen...

Page 90: ...een tested for compatibility are not designed in compliance with EMC standards and have low anti interference capability Additionally they bring electromagnetic interference to nearby devices Services are interrupted when an optical module is operating under overtemperature The operating temperature ranges of optical modules that have not been tested for compatibility cannot meet service requireme...

Page 91: ...ut the managed objects to the management system so that the management system can implement unified management of the devices E ejector lever A part on the panel of a device used to facilitate installation or removal of the device Ethernet A baseband local area network LAN architecture developed by Xerox Corporation by partnering with Intel and DEC Ethernet uses the Carrier Sense Multiple Access C...

Page 92: ...o ejector levers indicators and ports on the front or rear of the server It seals the front and rear of the chassis to ensure optimal ventilation and electromagnetic compatibility EMC Peripheral Component Interconnect Express PCIe A computer bus PCI which uses the existing PCI programming concepts and communication standards but builds a faster serial communication system Intel is the main sponsor...

Page 93: ...sical drives into a logical unit for the purposes of data redundancy and performance improvement S server A special computer that provides services for clients over a network System event log SEL Event records stored in the system used for subsequent fault diagnosis and system recovery B 5 U Z U U A unit defined in International Electrotechnical Commission IEC 60297 1 to measure the height of a ca...

Page 94: ...current AES Advanced Encryption Standard New Instruction Set ARP Address Resolution Protocol AVX Advanced Vector Extensions B BBU backup battery unit BIOS Basic Input Output System BMC Baseboard Management Controller C CCC China Compulsory Certification CD calendar day CE Conformite Europeenne CIM Common Information Model CLI command line interface ...

Page 95: ...mic random access memory DVD digital video disc E ECC error checking and correcting ECMA European Computer Manufacturer Association EDB Execute Disable Bit EID Enclosure ID backplane ID EN European Efficiency ERP enterprise resource planning ETS European Telecommunication Standards C 2 F J F FB DIMM Fully Buffered DIMM FC Fiber Channel FCC Federal Communications Commission FCoE Fibre Channel Over ...

Page 96: ...Secure I iBMC Intelligent Baseboard Management Controller IC Industry Canada ICMP Internet Control Message Protocol IDC Internet Data Center IEC International Electrotechnical Commission IEEE Institute of Electrical and Electronics Engineers IGMP Internet Group Message Protocol IOPS input output operations per second IP Internet Protocol IPC intelligent power capability IPMB Intelligent Platform M...

Page 97: ...ode LOM LAN on motherboard M MAC media access control MMC module management controller N NBD next business day NC SI Network Controller Sideband Interface O OCP Open Compute Project C 4 P T P PCIe Peripheral Component Interconnect Express PDU power distribution unit PHY physical layer PMBUS power management bus POK power OK PWM pulse width modulation PXE Preboot Execution Environment ...

Page 98: ... Substances in Electrical and Electronic Equipment S SAS Serial Attached Small Computer System Interface SATA Serial Advanced Technology Attachment SCM supply chain management SDDC single device data correction SERDES serializer deserializer SGMII serial gigabit media independent interface SMI serial management interface SMTP Simple Mail Transfer Protocol SNMP Simple Network Management Protocol SO...

Page 99: ...File Transfer Protocol TOE TCP offload engine TPM trusted platform module C 5 U Z U UBC Union Bus Connector UBC DD Union Bus Connector Double Density UDIMM unbuffered dual in line memory module UEFI Unified Extensible Firmware Interface UID unit identification light UL Underwriter Laboratories Inc UPI UltraPath Interconnect USB Universal Serial Bus V VCCI Voluntary Control Council for Interference...

Page 100: ...FusionServer G5500 V6 Server Technical White Paper C Acronyms and Abbreviations 2023 02 14 100 W WEEE Waste Electrical and Electronic Equipment WSMAN Web Service Management ...