FusionServer G5500 V6 Server
Technical White Paper
5 Hardware Description
2023-02-14
25
currently
5
PSU indicator
-
-
Indicator Description
Table 5-3
Indicators on the rear panel
Silkscreen
Indicator
Description
-
Data transmission
status indicator for
the management
network port
⚫
Off: No data is being transmitted.
⚫
Blinking yellow: Data is being
transmitted.
-
Connection status
indicator for the
management
network port
⚫
Off: The network is not connected.
⚫
Steady green: The network port is
properly connected.
-
PSU indicator
⚫
Off: No power is supplied.
⚫
Blinking green at 1 Hz:
−
The input is normal, and the
server is in the standby state.
−
The input is overvoltage or
undervoltage.
−
The PSU is in deep hibernation
mode.
⚫
Blinking green at 4 Hz: The firmware
is being upgraded online.
⚫
Steady green: The input and output
are normal.
⚫
Steady orange: The input is normal
but there is no output.
NOTE
The possible causes of no output are as
follows:
⚫
Power supply overtemperature protection
⚫
Power output overcurrent or short-circuit
⚫
Output overvoltage
⚫
Short-circuit protection
⚫
Device failure (excluding failure of all
devices)
UID indicator
The UID indicator helps identify and
locate a device.
⚫
Off: The device is not being located.
⚫
Blinking or steady blue: The device is
being located.