background image

Drive No.

Drive Number
Displayed on the iBMC
WebUI

Drive Number
Identified by the RAID
Controller Card

3

3

3

4

4

4

5

5

5

6

6

6

7

7

7

8

8

8

9

9

9

10

10

10

11

11

11

36

36

12

37

37

13

38

38

14

39

39

15

40

40

16

41

41

17

42

42

18

43

43

19

44

44

20

Note

45

45

21

Note

46

46

22

Note

47

47

23

Note

Note: If the slot is configured with a SAS/SATA drive, the RAID controller card
can manage the drive and allocate a number to the drive.

 

FusionServer 2288H V7 Server
Technical White Paper

5 Hardware Description

Issue 02 (2023-05-25)

Copyright © xFusion Digital Technologies Co., Ltd.

57

Summary of Contents for FusionServer 2288H V7

Page 1: ...FusionServer 2288H V7 Server Technical White Paper Issue 02 Date 2023 05 25 xFusion Digital Technologies Co Ltd...

Page 2: ...se of xFusion The purchased products services and features are stipulated by the contract made between xFusion and the customer All or part of the products services and features described in this docu...

Page 3: ...Indicates a hazard with a medium risk which if not avoided could result in death or serious injury Indicates a low level hazard which if not avoided could result in minor or moderate injury Indicates...

Page 4: ...ease Date Change Description 01 2021 06 21 This issue is the first official release FusionServer 2288H V7 Server Technical White Paper About This Document Issue 02 2023 05 25 Copyright xFusion Digital...

Page 5: ...Compatibility 27 5 4 1 4 DIMM Installation Rules 28 5 4 1 5 Memory Installation Positions 29 5 4 1 6 Memory Protection Technologies 32 5 5 Storage 32 5 5 1 Drive Configurations and Drive Numbering 32...

Page 6: ...ions 114 6 3 Physical Specifications 116 7 Software and Hardware Compatibility 118 8 Safety Instructions 119 8 1 Security 119 8 2 Maintenance and Warranty 122 9 System Management 124 10 Certifications...

Page 7: ...58 B 4 P T 158 B 5 U Z 159 C Acronyms and Abbreviations 160 C 1 A E 160 C 2 F J 161 C 3 K O 162 C 4 P T 163 C 5 U Z 165 FusionServer 2288H V7 Server Technical White Paper Contents Issue 02 2023 05 25...

Page 8: ...rmance computing distributed storage big data processing enterprise or telecom applications and other complex workloads The 2288H V7 features low power consumption high scalability high reliability an...

Page 9: ...t in drives Supports up to 24 x 2 5 NVMe U 2 drives improving storage density and I O performance The server supports a maximum of 14 standard slots including four built in slots Among the 14 slots up...

Page 10: ...C or BIOS The NC SI feature is disabled by default NOTE The service network port of the NC SI feature supports the following configurations It can be bound to any network port of the server s OCP 3 0...

Page 11: ...m Titanium PSUs with different energy efficiency levels The efficiency of the PSUs reaches 96 when the load is 50 Supports active standby power supply and high voltage DC power supply to improve the e...

Page 12: ...older 7 Air duct NOTE The air duct cannot be installed on a server configured with built in drives or built in cards 8 Intrusion sensor 9 Front drive backplane 10 Left mounting ear plate 11 Front driv...

Page 13: ...cessor heat sink 17 Processor 18 Cable organizer 19 Mainboard 20 Memory modules 21 TPM TCM 22 OCP 3 0 NIC 23 BMC card FusionServer 2288H V7 Server Technical White Paper 3 Physical Structure Issue 02 2...

Page 14: ...cessor are connected to the PCIe riser card through PCBs or cables Different PCIe riser cards support PCIe slots of different specifications CPU 1 and CPU 2 each support one OCP 3 0 NIC The PCIe slot...

Page 15: ...etwork 5 7 I O Expansion 5 8 PSUs 5 9 Fan Modules 5 10 LCD 5 11 Boards 5 1 Front Panel 5 1 1 Appearance 8 x 2 5 drive configuration Figure 5 1 Front view FusionServer 2288H V7 Server Technical White P...

Page 16: ...1 Drive 2 Slide out label plate with an SN label 12 x 3 5 drive configuration Figure 5 3 Front view 1 Drive 2 Slide out label plate with an SN label 24 x 2 5 drive configuration Figure 5 4 Front view...

Page 17: ...ndicators and buttons on the front panel 1 UID button indicator 2 Health status indicator 3 Power button indicator 4 Fault diagnosis LED 5 FlexIO card 1 presence indicator 6 FlexIO card 2 presence ind...

Page 18: ...12 x 3 5 drive configuration Figure 5 8 Indicators and buttons on the front panel 1 UID button indicator 2 Health status indicator 3 Power button indicator 4 Fault diagnosis LED 5 FlexIO card 1 presen...

Page 19: ...ort indicator 25 x 2 5 drive configuration Figure 5 10 Indicators and buttons on the front panel 1 UID button indicator 2 Health status indicator 3 Power button indicator 4 Fault diagnosis LED 5 FlexI...

Page 20: ...on the system Blinking red at 5 Hz A critical alarm has been generated on the system Steady green The device is operating properly FlexIO card presence indicator Indicates whether the FlexIO card is d...

Page 21: ...ce is powered on you can hold down this button for 6 seconds to forcibly power off the device When the power indicator is steady yellow you can press this button to power on the device UID button indi...

Page 22: ...fails or an error is reported when the job is complete Blinking green at short intervals The job is being executed Blinking green at short intervals for 3 seconds and then off The port is disabled St...

Page 23: ...1 USB 3 0 port 2 iBMC direct connect management port 3 VGA port 24 x 2 5 drive configuration Figure 5 14 Ports on the front panel 1 USB 3 0 port 2 iBMC direct connect management port 3 VGA port 25 x...

Page 24: ...nly local PCs running Windows 10 are supported To log in to the iBMC from a local PC enter https IP address of the iBMC management network port in the address box of the browser on the local PC Used t...

Page 25: ...external CD DVD drives an external power supply is required Note The number of ports varies depending on server configuration This table lists the maximum number of ports in different configurations 5...

Page 26: ...eference only The actual configuration may vary 4 GPU model Figure 5 17 Rear view 1 Slot 1 2 Slot 4 3 Slot 7 4 Slot 9 5 PSU 2 6 PSU 1 7 Optional FlexIO card 2 NOTE The FlexIO card slots support only O...

Page 27: ...port indicator NOTE Reserved and unavailable currently 4 UID indicator 5 PSU indicator 4 GPU model Figure 5 19 Indicators on the rear panel 1 Data transmission status indicator for the management net...

Page 28: ...nput is normal and the server is in the standby state The input is overvoltage or undervoltage The PSU is in deep hibernation mode Blinking green at 4 Hz The firmware is being upgraded online Steady g...

Page 29: ...g the UID button or using the iBMC 5 2 3 Ports Port Positions Server with a drive module or PRM on the rear panel Figure 5 20 Ports on the rear panel 1 Management network port 2 Serial port 3 VGA port...

Page 30: ...l communication port and its default baud rate is 115 200 bit s VGA port DB15 1 Used to connect a display terminal such as a monitor or KVM USB port USB 3 0 2 Used to connect to a USB 3 0 device NOTIC...

Page 31: ...supports one or two processors If only one processor is required install it in socket CPU 1 Processors of the same model must be used in a server For details about the optional components consult the...

Page 32: ...R Single rank 2R Dual rank 4R Quad rank 8R Octal rank 3 Data width on the DRAM x4 4 bit x8 8 bit 4 Type of the memory interface PC5 DDR5 5 Maximum memory speed 4800 MT s 6 Memory latency parameters CL...

Page 33: ...rimary memory channels first If the primary memory channel is not populated the memory modules in secondary memory channels cannot be used Table 5 5 Memory channels CPU Channel Memory Slot CPU 1 A pri...

Page 34: ...the following two speed values Memory speed supported by a CPU Maximum operating speed of a memory module The DDR5 memory modules of different types RDIMM and RDIMM 3DS and specifications capacity bi...

Page 35: ...4800 4800 4800 4800 2DPC 4400 4400 4400 4400 a The maximum number of DDR5 memory modules is based on dual processor configuration The number is halved for a server with only one processor b DIMM per...

Page 36: ...memory module installation rules when configuring memory modules For details see Memory Configuration Assistant Figure 5 24 Positions of the memory modules FusionServer 2288H V7 Server Technical White...

Page 37: ...e 5 25 DDR5 memory module installation guidelines 1 processor FusionServer 2288H V7 Server Technical White Paper 5 Hardware Description Issue 02 2023 05 25 Copyright xFusion Digital Technologies Co Lt...

Page 38: ...e 5 26 DDR5 memory module installation guidelines 2 processors FusionServer 2288H V7 Server Technical White Paper 5 Hardware Description Issue 02 2023 05 25 Copyright xFusion Digital Technologies Co L...

Page 39: ...le Region ADDDC MR Partial Cache Line Sparing PCLS HBM only 5 5 Storage 5 5 1 Drive Configurations and Drive Numbering 5 5 1 1 8 x 2 5 Drive Pass Through Configurations Drive Configurations Table 5 7...

Page 40: ...U pass through 8 x 2 5 drive pass through configuration 3 Front drive 8 x 2 5 Slots 0 to 7 support only SATA NVMe drivesa SATA drive PCH pass through NVMe drive CPU pass through 8 x 2 5 drive pass thr...

Page 41: ...ives For details about the optional components consult the local sales representative or see OS and Parts Compatibility in the Compatibility Checker Drive Numbering NOTICE The drive numbers identified...

Page 42: ...e iBMC WebUI 0 0 1 1 2 2 3 3 4 4 5 5 6 6 7 7 44 44 45 45 46 46 47 47 Drive numbering of the 8 x 2 5 drive pass through configuration 2 in Table 5 7 FusionServer 2288H V7 Server Technical White Paper 5...

Page 43: ...Controller Card 0 0 0 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 44 44 45 45 46 46 47 47 Drive numbering of the 8 x 2 5 drive pass through configuration 3 in Table 5 7 Figure 5 29 Drive numbering Fusi...

Page 44: ...mbering Table 5 11 Drive numbering Drive No Drive Number Displayed on the iBMC WebUI Drive Number Identified by the RAID Controller Card 0 0 0 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 Drive numbering...

Page 45: ...2 8 x 2 5 drives 4 x GPU cards in Table 5 7 Figure 5 32 Drive numbering Table 5 13 Drive numbering Drive No Drive Number Displayed on the iBMC WebUI Drive Number Identified by the RAID Controller Card...

Page 46: ...Rear Drive Built in Drive Drive Management Mode 12 x 2 5 drive 4 x SATA 8 x NVMe pass through configuration 1 Front drive 12 x 2 5 Slots 0 to 3 support only SATA drives Slots 4 and 7 support only SATA...

Page 47: ...D controller card The PCIe plug in RAID controller card is installed in slot 3 by default NVMe drive CPU pass through 12 x 2 5 drive 4 x SATA 8 x NVMe 4 x GPU card configuration 1 Front drive 12 x 2 5...

Page 48: ...and Parts Compatibility in the Compatibility Checker Drive numbering NOTICE The drive numbers identified by the RAID controller card vary depending on the cabling of the RAID controller card This sec...

Page 49: ...and 12 x 2 5 drive 4 x SATA 8 x NVMe 4 x GPU card configuration 2 in Table 5 14 Figure 5 34 Drive numbering Table 5 16 Drive numbering Drive No Drive Number Displayed on the iBMC WebUI Drive Number Id...

Page 50: ...rations Table 5 17 Drive configurations Configuratio n Front Drive Rear Drive Built in Drive Drive Management Mode 12 x 3 5 drive pass through configuration 1 Front drive 12 x 3 5 Slots 0 to 11 suppor...

Page 51: ...he PCIe plug in RAID controller card is installed in slot 3 by default NVMe drive CPU pass through 12 x 3 5 drive pass through configuration 3 Front drive 12 x 3 5 Slots 0 to 11 support only SAS SATA...

Page 52: ...ss through configuration 2 4 x NVMe Front drive 12 x 3 5 Slots 0 to 7 support only SAS SATA drives Slots 8 to 11 support SAS SATA NVMe drives I O module 1 2 x 2 5 a Slots 40 to 41 support only SAS SAT...

Page 53: ...ified by the RAID controller card vary depending on the cabling of the RAID controller card This section uses the drive numbers identified by a RAID controller card that adopts the default cabling des...

Page 54: ...8 8 9 9 10 10 11 11 40 40 41 41 44 44 45 45 46 46 47 47 Drive numbering of the 12 x 3 5 drive pass through configuration 2 in Table 5 17 Figure 5 37 Drive numbering FusionServer 2288H V7 Server Techn...

Page 55: ...2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 8 8 8 9 9 9 10 10 10 11 11 11 40 40 12 41 41 13 42 42 14 43 43 15 44 44 45 45 46 46 47 47 Drive numbering of the 12 x 3 5 drive pass through configuration 3 in Table 5...

Page 56: ...played on the iBMC WebUI Drive Number Identified by the RAID Controller Card 0 0 0 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 8 8 8 9 9 9 FusionServer 2288H V7 Server Technical White Paper 5 Hardware D...

Page 57: ...6 46 47 47 Drive numbering of the 12 x 3 5 drive pass through configuration 1 4 x NVMe in Table 5 17 Figure 5 39 Drive numbering Table 5 21 Drive numbering Drive No Drive Number Displayed on the iBMC...

Page 58: ...through configuration 2 4 x NVMe in Table 5 17 Figure 5 40 Drive numbering Table 5 22 Drive numbering Drive No Drive Number Displayed on the iBMC WebUI Drive Number Identified by the RAID Controller...

Page 59: ...10 10Note 11 11 11Note 40 40 12 41 41 13 42 42 14 43 43 15 44 44 45 45 46 46 47 47 Note If the slot is configured with a SAS SATA drive the RAID controller card can manage the drive and allocate a nu...

Page 60: ...1 2 x 2 5 a Slots 40 to 41 support only SAS SATA drives I O module 2 2 x 3 5 Slots 42 to 43 support only SAS SATA drives I O module 3 4 x 2 5 Slots 44 to 47 support only NVMe drivesb SAS SATA drive 1...

Page 61: ...e 1 2 x 2 5 is configured with rear 2 x 2 5 drives and a PCIe riser module b NVMe drives are supported when CPU 2 is configured A single CPU server does not support NVMe drives For details about the o...

Page 62: ...Displayed on the iBMC WebUI Drive Number Identified by the RAID Controller Card 0 0 0 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 8 8 8 9 9 9 10 10 10 11 11 11 40 40 12 41 41 13 42 42 14 43 43 15 44 44...

Page 63: ...EXP configuration 2 in Table 5 23 Figure 5 42 Drive numbering Table 5 25 Drive numbering Drive No Drive Number Displayed on the iBMC WebUI Drive Number Identified by the RAID Controller Card 0 0 0 1 1...

Page 64: ...8 38 14 39 39 15 40 40 16 41 41 17 42 42 18 43 43 19 44 44 20Note 45 45 21Note 46 46 22Note 47 47 23Note Note If the slot is configured with a SAS SATA drive the RAID controller card can manage the dr...

Page 65: ...ort NVMe drives For details about the optional components consult the local sales representative or see OS and Parts Compatibility in the Compatibility Checker Drive Numbering NOTICE The drive numbers...

Page 66: ...entified by the RAID Controller Card 0 0 0 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 8 8 0 9 9 1 10 10 2 11 11 3 12 12 4 13 13 5 14 14 6 15 15 7 16 16 0 17 17 1 18 18 2 19 19 3 FusionServer 2288H V7 S...

Page 67: ...Drive Number Identified by the RAID Controller Card 20 20 4 21 21 5 22 22 6 23 23 7 44 44 45 45 46 46 47 47 FusionServer 2288H V7 Server Technical White Paper 5 Hardware Description Issue 02 2023 05 2...

Page 68: ...ion 1 8 x SATA 16 x NVMe Front drive 24 x 2 5 Slots 0 to 3 support only SATA drives Slots 4 to 11 support only NVMe drives Slots 12 to 15 support only SATA drives Slots 16 to 23 support only NVMe driv...

Page 69: ...11 support only NVMe drives Slots 12 to 15 support only SAS SATA drives Slots 16 to 23 support only NVMe drives SAS SATA drive 1 x PCIe plug in RAID controller card The PCIe plug in RAID controller ca...

Page 70: ...ort only SATA NVMe drives Slots 4 to 11 support only NVMe drives Slots 12 to 15 support only SATA NVMe drives Slots 16 to 23 support only NVMe drives SATA drive PCH pass through NVMe drive CPU pass th...

Page 71: ...TA drive 1 x PCIe plug in RAID controller card The PCIe plug in RAID controller card is installed in slot 3 by default NVMe drive CPU pass through 24 x 2 5 drive NVMe configuration 5 Front drive 24 x...

Page 72: ...lt the local sales representative or see OS and Parts Compatibility in the Compatibility Checker Drive numbering NOTICE The drive numbers identified by the RAID controller card vary depending on the c...

Page 73: ...10 11 11 12 12 13 13 14 14 15 15 16 16 17 17 18 18 19 19 20 20 21 21 22 22 23 23 Drive numbering of the 24 x 2 5 drive NVMe configuration 2 8 x SAS SATA 16 x NVMe in Table 5 28 FusionServer 2288H V7 S...

Page 74: ...Identified by the RAID Controller Card 0 0 0 1 1 1 2 2 2 3 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 4 13 13 5 14 14 6 15 15 7 16 16 17 17 18 18 19 19 20 20 21 21 22 22 FusionServer 2288H V7 Serv...

Page 75: ...ing Table 5 31 Drive numbering Drive No Drive Number Displayed on the iBMC WebUI Drive Number Identified by the RAID Controller Card 0 0 0Note 1 1 1Note 2 2 2Note 3 3 3Note 4 4 5 5 6 6 7 7 8 8 9 9 10...

Page 76: ...ler card can manage the drive and allocate a number to the drive Drive numbering of the 24 x 2 5 drive NVMe configuration 5 in Table 5 28 Figure 5 47 Drive numbering Table 5 32 Drive numbering Drive N...

Page 77: ...5 15 16 16 17 17 18 18 19 19 20 20 21 21 22 22 23 23 44 44 45 45 46 46 47 47 Drive numbering of the 24 x 2 5 drive NVMe configuration 6 in Table 5 28 FusionServer 2288H V7 Server Technical White Paper...

Page 78: ...ebUI Drive Number Identified by the RAID Controller Card 0 0 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 13 13 14 14 15 15 16 16 17 17 18 18 19 19 FusionServer 2288H V7 Server Technical Whit...

Page 79: ...Drive Number Identified by the RAID Controller Card 20 20 21 21 22 22 23 23 44 44 0 45 45 1 46 46 2 47 47 3 FusionServer 2288H V7 Server Technical White Paper 5 Hardware Description Issue 02 2023 05 2...

Page 80: ...rivesb SAS SATA drive 1 x PCIe plug in RAID controller card The PCIe plug in RAID controller card is installed in slot 3 by default NVMe drive CPU pass through a The I O module 2 x 2 5 is configured w...

Page 81: ...2288H V7 Server Maintenance and Service Guide Drive numbering of the 25 x 2 5 drive EXP configuration in Table 5 34 Figure 5 49 Drive numbering Table 5 35 Drive numbering Drive No Drive Number Display...

Page 82: ...13 13 13 14 14 14 15 15 15 16 16 16 17 17 17 18 18 18 19 19 19 20 20 20 21 21 21 22 22 22 23 23 23 24 24 24 40 40 25 41 41 26 42 42 27 43 43 28 44 44 45 45 46 46 47 47 FusionServer 2288H V7 Server Tec...

Page 83: ...Off Data is being read or written properly or data on the primary drive is being rebuilt Steady on Blinking blue at 4 Hz The drive is being located Blinking at 1 Hz Blinking red at 1 Hz synchronously...

Page 84: ...y on blinking Blinking blue at 4 Hz The NVMe drive is being located Blinking at 1 Hz Blinking red at 1 Hz synchronously Data on the NVMe secondary drive is being rebuilt Steady on Off Red steady on Th...

Page 85: ...in the Compatibility Checker For details about the RAID controller card see the V7 Server RAID Controller Card User Guide 5 6 Network 5 6 1 OCP 3 0 NIC OCP 3 0 NICs provide network expansion capabili...

Page 86: ...same For details contact technical support 5 7 2 PCIe Slots PCIe Slots Server with a drive module or PCIe riser module on the rear panel Figure 5 52 PCIe slots I O module 1 provides slots 1 2 and 3 I...

Page 87: ...licable to the Server with a Drive Module or a PCIe Riser Module on the Rear Panel PCIe riser card 1 of I O module 1 2 Provides PCIe slots 1 2 and 3 when installed in I O module 1 Provides PCIe slots...

Page 88: ...des PCIe slots 2 and 3 when installed in I O module 1 Provides PCIe slots 5 and 6 when installed in I O module 2 Figure 5 57 PCIe riser card 3 PCIe riser card 4 of I O module 1 2 Provides PCIe slot 3...

Page 89: ...1 of I O module 3 Provides PCIe slots 7 and 8 when installed in I O module 3 Figure 5 60 PCIe riser card 1 PCIe riser card 2 of I O module 3 Provides slots 7 and 8 when one PCIe riser card 2 is instal...

Page 90: ...n the card slot 4CHP connector J10 Figure 5 62 PCIe riser card 1 PCIe riser card applicable to 4 GPU models PCIe riser card 1 for the rear GPU module For details see 4 GPU built in adapter board when...

Page 91: ...rd slot 4CHP connector J13 Figure 5 64 PCIe riser card 3 5 7 3 PCIe Slot Description NOTE When CPU 2 is not detected the corresponding PCIe slot is unavailable The PCIe port numbers in table 1 corresp...

Page 92: ...HHL I O module 2 Slot 4 PCIe 5 0 x16 x 16 CPU 2 Port 1A FHHL Slot 5 PCIe 4 0 x16 x8 CPU 2 Port 2A FHHL Slot 6 PCIe 4 0 x16 x8 CPU 2 Port 2C FHHL PCIe riser card 2 of I O module 1 2 I O module 1 Slot 1...

Page 93: ...16 x16 CPU 2 Port 0A FHFL PCIe riser card 1 of I O module 3 I O module 3 Slot 7 PCIe 4 0 x16 x16 CPU 2 Port 3A FHHL Slot 8 PCIe 4 0 x16 x16 CPU 2 Port 4A FHHL PCIe riser card 2 of I O module 3 I O mod...

Page 94: ...ots are compatible with PCIe x16 PCIe x8 PCIe x4 and PCIe x1 cards The bandwidth of the PCIe slot cannot be less than that of the inserted PCIe card The full height full length FHFL PCIe slots are com...

Page 95: ...d 1 supports the Socket Direct function when it is connected to the two CPUs through high speed cables e The default link bandwidth of FlexIO card 2 is x8 The link bandwidth can be extended to x16 usi...

Page 96: ...to make the OS support the command Windows OS After installing the pci utils package run the lspci command to obtain the B D F information of the server VMware OS The lspci command is supported by def...

Page 97: ...ass through configuration supports the LCD Functions The LCD displays the installation status and running status of server components and enables users to set the IP address of the iBMC management net...

Page 98: ...ns Status Displays the port 80 status serial number component status and component alarms of the server Monitor Displays the current power CPU temperature and inlet temperature of the server FusionSer...

Page 99: ...information and firmware version Setting Sets the IP address of the iBMC management network port For details about how to use the LCD see FusionServer Rack Server LCD User Guide 5 11 Boards FusionServ...

Page 100: ...J6066 3 Cell battery holder U6222 4 CPU 2 UBC DD connector UBCDD2 7 J6053 5 OCP 3 0 NIC 2 connector OCP2 CONN J6073 6 RAID M 2 mezzanine card signal connector RAID M 2 J6063 FusionServer 2288H V7 Ser...

Page 101: ...24 Rear I O module 1 power connector IO1 PWR J6092 25 PCH SATA port C connector PORTC J6100 26 Right mounting ear connector J6060 27 Fan board power connector FAN PWR J6094 28 PCH SATA ports A and B...

Page 102: ...or PSU1 J6095 51 CPU 2 UBC DD connector UBCDD2 8 J6054 52 Built in drive module power connector INNER PWR J6090 a The reserved connector is temporarily unavailable 5 11 2 Drive Backplane Front Drive B...

Page 103: ...Mini SAS HD connector PORT B J1 Slots 4 to 7 8 x 2 5 drive pass through backplane This backplane is supported by 8 x 2 5 drive pass through configuration 3 and 8 x 2 5 drive pass through configuratio...

Page 104: ...UBC2 J2 Slots 2 to 3 4 Backplane signal cable connector HDD_BP J20 5 UBC connector 1 UBC1 J1 Slots 0 to 1 6 Power connector HDD_POWER J21 7 Mini SAS HD connector PORT A J6 Slots 0 to 3 8 Mini SAS HD...

Page 105: ...lots 8 to 9 3 UBC connector 2 UBC2 J2 Slots 6 to 7 4 UBC connector 1 UBC1 J1 Slots 4 to 5 5 JTAG connector J20 6 Backplane signal connector HDD BP J19 7 Power connector HDD_POWER J21 8 Mini SAS HD con...

Page 106: ...5 Power connector HDD_POWER J21 6 Backplane signal cable connector HDD BP J19 7 Indicator signal cable connector REAR BP1 J18 8 UBC connector 1 UBC1 J1 Slots 8 to 9 9 UBC connector 2 UBC2 J2 Slots 10...

Page 107: ...nector HDD BP J1202 6 Low speed signal connector for I O module 2 REAR BP1 J32 7 High speed signal connector for I O module 1 2 REAR PORT IO1 2 J34 8 UBC connector J1 24 x 2 5 drive NVMe backplane All...

Page 108: ...nector 2 A UBC2 A J1 Slots 0 to 1 11 Backplane signal cable connector HDD BP J40 12 Power connector HDD_POWER J41 13 Mini SAS HD connector PORT A J13 Slots 0 to 3 14 UBC connector 2 D UBC2 D J4 Slots...

Page 109: ...nector HDD_BP J2 25 x 2 5 drive EXP backplane All drive configurations in 5 5 1 7 25 x 2 5 Drive EXP Configurations support this backplane Figure 5 77 25 x 2 5 drive EXP backplane 1 Low speed signal c...

Page 110: ...3 5 drive backplane No Connector Managed Drive Slot 1 Mini SAS HD connector PORT B J401 Slots 38 to 39 2 Mini SAS HD connector PORT A J28 Slots 36 to 37 3 Backplane signal cable connector HDD BP J19 4...

Page 111: ...e connector HDD BP J17 3 Mini SAS HD connector PORT A J28 Management slot for I O module 1 slots 40 to 41 Management slot for I O module 2 slots 42 to 43 2 x 3 5 drive backplane FusionServer 2288H V7...

Page 112: ...connector PORT A J28 Management slot for I O module 1 slots 40 to 41 Management slot for I O module 2 slots 42 to 43 3 Power connector HDD PWR J21 4 x 2 5 SAS SATA NVMe drive backplane FusionServer 22...

Page 113: ...01 3 Mini SAS HD connector PORT A J28 Slots 44 to 47 4 UBC connector 2 UBC2 J2 Slots 46 to 47 5 UBC connector 1 UBC1 J1 Slots 44 to 45 4 x 2 5 NVMe drive backplane Figure 5 82 4 x 2 5 drive backplane...

Page 114: ...J3 2 Reserved and unavailable currently 3 Fan board power connector J10 GND_BLACK J11 POWER_RED 4 Reserved and unavailable currently 5 Reserved and unavailable currently 6 Fan connector FAN1 J7 7 Fan...

Page 115: ...3 J5 6 UBC connector 4 UBC4 J6 7 UBC connector 2 UBC2 J4 4 x GPU built in adapter board Figure 5 85 4 x GPU built in adapter board 1 Card slot 4CHP connector Riser4 J13 2 Card slot 4CHP connector Rise...

Page 116: ...3 10 UBC connector 2 UBCDD1 8 2 J4 11 UBC connector 3 UBC1 3 J5 12 UBC connector 4 UBC1 4 J6 13 UBC connector 5 UBC2 3 J8 14 UBC connector 6 UBC2 4 J7 15 UBC connector 7 UBCDD2 8 2 J20 16 UBC connecto...

Page 117: ...nd eight memory channels per processor Built in PCIe controller supporting PCIe 5 0 and 80 lanes per processor Four UltraPath Interconnect UPI buses between processors providing up to 16 GT s transmis...

Page 118: ...tion If yes check whether the VMD driver needs to be manually installed and check the installation method When the VMD function is enabled and the latest VMD driver is installed surprise hot swap is s...

Page 119: ...5 7 2 PCIe Slots and 5 7 3 PCIe Slot Description NOTE The preceding information is for reference only For details see Search Parts in the Compatibility Checker Port Supports a variety of ports Ports...

Page 120: ...tion supported by the operating system is provided If both the front and rear VGA ports are connected to monitors only the monitor connected to the front VGA port displays information System managemen...

Page 121: ...thin one year 20 to 75 Maximum change humidity rate 20 per hour Air volume 120 cubic feet per minute CFM to 320 CFM Operating altitude 3050 m 10 006 56 ft When the server configuration complies with A...

Page 122: ...0 Bels LpAm 44 6 dBA NOTE Actual sound levels generated during operation vary depending on the configuration load and ambient temperature NOTE SSDs and HDDs including NL SAS SAS and SATA cannot be pr...

Page 123: ...x 31 42 in Figure 6 1 Physical dimensions example a chassis with 3 5 drives NOTE See Figure 6 1 for methods in measuring physical dimensions of the chassis The measuring method for chassis with 3 5 d...

Page 124: ...rear mounting bars Weight in full configuration Net weight Maximum weight for server with 8 x 2 5 front drives 22 5 kg 49 60 lb Maximum weight for server with 12 x 2 5 front drives 23 5 kg 51 80 lb Ma...

Page 125: ...tency between the application layer and test software layer If the customer has requirements on the performance of specific application software contact technical support to apply for proof of concept...

Page 126: ...this device may cause radio interference Human Safety This device is not suitable for use in places where children may be present Only certified or authorized personnel are allowed to install equipme...

Page 127: ...removed before you touch a device Figure 8 2 Removing conductive objects Figure 8 3 shows how to wear an ESD wrist strap a Secure the ESD wrist strap around your wrist b Fasten the strap buckle and en...

Page 128: ...ers Do not use them for other devices Before operating equipment wear ESD clothes and gloves to prevent electrostatic sensitive devices from being damaged by ESD When moving a device hold the bottom o...

Page 129: ...riptions in the documentation are for reference only Table 8 1 lists the maximum weight one person is permitted to carry as stipulated by a number of organizations Table 8 1 Maximum weight carried per...

Page 130: ...For details on warranty see Warranty FusionServer 2288H V7 Server Technical White Paper 8 Safety Instructions Issue 02 2023 05 25 Copyright xFusion Digital Technologies Co Ltd 123...

Page 131: ...stable uninterrupted 24 7 system operation by providing the following features The last screenshot and video recording function when the system crashes makes it impossible to analyze the cause of the...

Page 132: ...onfiguration and upgrades to simplify server installation and configuration Diversified network protocols Supports NTP to improve the device time configuration capability and synchronizes the network...

Page 133: ...2015 A1 2019 EN IEC 61000 3 2 2019 A1 2021 EN 61000 3 2 2013 A2 2021 EN 61000 3 2 2014 EN 61000 3 3 2013 EN 55035 2017 A11 2020 CISPR 35 2016 EN 55024 2010 A1 2015 CISPR 24 2010 A1 2015 RoHS EN IEC 63...

Page 134: ...3 A2 2021 EN 61000 3 2 2014 EN 61000 3 3 2013 EN 55035 2017 A11 2020 CISPR 35 2016 EN 55024 2010 A1 2015 CISPR 24 2010 A1 2015 RoHS BS EN IEC 63000 2018 ErP Commission Regulation EU No 2019 424 China...

Page 135: ...ss tag 4 Product SN NOTE For details see A 2 Product SN 5 Reserved space for customized label 6 Pressure proof label NOTE This label warns users not to place any objects on top of a rack mounted devic...

Page 136: ...el NOTE For details see A 4 Nameplate 2 Device name 3 Power supply requirements 4 Vendor information 5 Certification marks A 1 1 2 Certificate Figure A 3 Certificate example FusionServer 2288H V7 Serv...

Page 137: ...finished server N a spare part 4 0 a value for the reserved digit 5 Year two characters 6 Month one character Digits 1 to 9 indicate January to September respectively Letters A to C indicate October t...

Page 138: ...A 5 Quick access label example Table A 4 Quick access label description No Description 1 IP address of the iBMC management network port 2 Subnet mask of the iBMC management network port 3 Default iBM...

Page 139: ...nd QR codes of technical resources The pictures are for reference only For details see the actual product The quick start guide is optional For details see the actual product A 1 3 Chassis Tail Label...

Page 140: ...years 2001 to 2009 respectively Letters A to H indicate years 2010 to 2017 respectively Letters J to N indicate years 2018 to 2022 respectively Letters P to Y indicate years 2023 to 2032 respectively...

Page 141: ...ctively Letters P to Y indicate years 2023 to 2032 respectively NOTE The years from 2010 are represented by upper case letters excluding I O and Z because the three letters are similar to the digits 1...

Page 142: ...ot supporte d A40 GPU cards are not supporte d OCP 3 0 NICs whose rate is greater than 100 Gbit s are not supporte d 6434 64 34H CPUs and CPUs with TDP greater than 205 W are not supporte d when the b...

Page 143: ...Superca pacitors are not supporte d 6434 64 34H CPUs and CPUs with TDP greater than 205 W are not supporte d when the built in 4 card module is configur ed Gbit s are not supporte d Superca pacitors...

Page 144: ...8 x 2 5 drives 4 x GPUs configuratio n All configur ations are supporte d All configur ations are supporte d CPUs with TDP greater than 250 W are not supporte d GPU cards are not supporte d OCP 3 0 NI...

Page 145: ...ith TDP greater than 250 W are not supporte d A40 GPU cards are not supporte d OCP 3 0 NICs whose rate is greater than 100 Gbit s are not supporte d CPUs with TDP greater than 185 W are not supporte d...

Page 146: ...5 drives 4 x SAS SATA 8 x NVMe 4 x GPUs configuratio n All configur ations are supporte d All configur ations are supporte d CPUs with TDP greater than 250 W are not supporte d GPU cards are not supp...

Page 147: ...supporte d The A2 GPU cards are not supporte d when the CPU TDP is higher than 270 W GPU cards are not supporte d 6434 64 34H CPUs and CPUs with TDP greater than 205 W are not supporte d when the buil...

Page 148: ...mperatu re 45 C 113 F Maximum Operating Temperatu re 50 C 118 F configur ed supporte d 6434 64 34H CPUs and CPUs with TDP greater than 205 W are not supporte d when the built in 4 x 3 5 drives or 4 ca...

Page 149: ...e not supporte d The A2 GPU cards are not supporte d when the CPU TDP is higher than 270 W 6434 64 34H CPUs and CPUs with TDP greater than 205 W are not supporte d when the built in 4 x 3 5 drives or...

Page 150: ...ing Temperatu re 45 C 113 F Maximum Operating Temperatu re 50 C 118 F supporte d 6434 64 34H CPUs and CPUs with TDP greater than 205 W are not supporte d when the built in 4 x 3 5 drives or 4 card mod...

Page 151: ...not supporte d A16 A40 A100 GPU cards are not supporte d Rear HDDs and NVMe drives are not supporte d OCP 3 0 NICs whose rate is greater than 100 Gbit s are not supporte d CPUs with TDP greater than...

Page 152: ...e d Rear HDDs and NVMe drives are not supporte d OCP 3 0 NICs whose rate is greater than 100 Gbit s are not supporte d PCIe NICs whose rate is greater than 100 Gbit s are not supporte d CPUs with TDP...

Page 153: ...in 4 card module is configur ed 6434 64 34H CPUs and CPUs with TDP greater than 250 W are not supporte d GPU cards are not supporte d Rear HDDs and NVMe drives are not supporte d OCP 3 0 NICs whose ra...

Page 154: ...C 113 F Maximum Operating Temperatu re 50 C 118 F W are not supporte d when the built in 4 card module is configur ed 6434 64 34H CPUs and CPUs with TDP greater than 205 W are not supporte d when the...

Page 155: ...s configur ed 6434 64 34H CPUs and CPUs with TDP greater than 250 W are not supporte d GPU cards are not supporte d Rear HDDs and NVMe drives are not supporte d OCP 3 0 NICs whose rate is greater than...

Page 156: ...value When a single fan is faulty the system performance may be affected It is recommended that servers be deployed at an interval of 1U to reduce server noise and improve server energy efficiency Li...

Page 157: ...perature and the CPU core temperature threshold CPUN N indicates the CPU number The value is 1 or 2 CpuN Margin Difference between the real time CPU temperature and the CPU Tcontrol threshold CPUN N i...

Page 158: ...2 CPUN FIVRA CPU FIVRA voltage Mainboard or CPU N N indicates the CPU number The value is 1 or 2 CPUN INFAON CPU INFAON voltage CPUN N indicates the CPU number The value is 1 or 2 CPUN VCCFA CPU VCCF...

Page 159: ...tput current PSUs PS POut PSU output power PSUs PS Temp Maximum internal temperature of the PSU PSUs PS Inlet Temp PSU air inlet temperature PSUs PSN Status PSU fault status PSU N N indicates the PSU...

Page 160: ...MM N N indicates the DIMM slot number RTC Battery RTC battery status An alarm is generated when the voltage is lower than 1 V RTC battery on the mainboard Power Button Power button pressed state Mainb...

Page 161: ...the RAID controller card RAID controller card Raid BBU Temp BBU temperature of the RAID controller card Supercapacitor of the RAID controller card PCIE Status PCIe status error PCIe card PCIe OP Temp...

Page 162: ...emp HBM chip temperature of the GPU card GPU card System Notice Hot restart reminder and fault diagnosis program information collection N A System Error System suspension or restart Check the backgrou...

Page 163: ...og Full Security log full or events being cleared Host Loss System monitoring software BMA link loss detection ProductID Status Product identification status FusionServer 2288H V7 Server Technical Whi...

Page 164: ...ment of the devices E ejector lever A part on the panel of a device used to facilitate installation or removal of the device Ethernet A baseband local area network LAN architecture developed by Xerox...

Page 165: ...e server It seals the front and rear of the chassis to ensure optimal ventilation and electromagnetic compatibility EMC Peripheral Component Interconnect Express PCIe A computer bus PCI which uses the...

Page 166: ...pecial computer that provides services for clients over a network system event log SEL Event records stored in the system used for subsequent fault diagnosis and system recovery B 5 U Z U U A unit def...

Page 167: ...B BBU backup battery unit BIOS Basic Input Output System BMC baseboard management controller C CCC China Compulsory Certification CD calendar day CE Conformite Europeenne CIM Common Information Model...

Page 168: ...rer Association EDB Execute Disable Bit EID enclosure ID EN European Efficiency ERP enterprise resource planning ETS European Telecommunication Standards C 2 F J F FB DIMM Fully Buffered DIMM FC Fiber...

Page 169: ...tocol IDC Internet Data Center IEC International Electrotechnical Commission IEEE Institute of Electrical and Electronics Engineers IGMP Internet Group Message Protocol IOPS input output operations pe...

Page 170: ...k Controller Sideband Interface O OCP Open Compute Project C 4 P T P PCIe Peripheral Component Interconnect Express PDU power distribution unit PHY physical layer PMBUS power management bus POK Power...

Page 171: ...single device data correction SERDES serializer deserializer SGMII serial gigabit media independent interface SMI serial management interface SMTP Simple Mail Transfer Protocol SNMP Simple Network Ma...

Page 172: ...d Extensible Firmware Interface UID unit identification light UL Underwriter Laboratories Inc UPI UltraPath Interconnect USB Universal Serial Bus V VCCI Voluntary Control Council for Interference by I...

Page 173: ...WSMAN Web Service Management FusionServer 2288H V7 Server Technical White Paper C Acronyms and Abbreviations Issue 02 2023 05 25 Copyright xFusion Digital Technologies Co Ltd 166...

Reviews: