5
PSU indicator
-
-
Indicator Description
Table 5-3
Indicators on the rear panel
Silkscreen
Indicator
Description
-
Data transmission
status indicator for
the management
network port
● Off: No data is being transmitted.
● Blinking yellow: Data is being
transmitted.
-
Connection status
indicator for the
management
network port
● Off: The network is not connected.
● Steady green: The network port is
properly connected.
-
PSU indicator
● Off: No power is supplied.
● Blinking green at 1 Hz:
– The input is normal, and the
server is in the standby state.
– The input is overvoltage or
undervoltage.
– The PSU is in deep hibernation
mode.
● Blinking green at 4 Hz: The firmware
is being upgraded online.
● Steady green: The input and output
are normal.
● Steady orange: The input is normal
but there is no output.
NOTE
The possible causes of no output are as
follows:
● Power supply overtemperature
protection
● Power output overcurrent or short-
circuit
● Output overvoltage
● Short-circuit protection
● Device failure (excluding failure of all
devices)
FusionServer 2288H V7 Server
Technical White Paper
5 Hardware Description
Issue 02 (2023-05-25)
Copyright © xFusion Digital Technologies Co., Ltd.
21