FUSER LUBRICANT AND PRESSURE ROLL WIPER
4-4
XEROX DOCUPRINT 4850/4890 IPS GUIDE TO PERFORMING ROUTINE MAINTENANCE
11. Remove and dispose of the gloves in a trash receptacle, being
careful not to let any residue come in contact with your skin.
12. Close the printer doors.
13. Wash your hands to remove any fuser lubricant.
Replacing the pressure roll wiper
You need to replace the pressure roll wiper when any of the following
occur:
•
Excessive oil or dirt buildup appears on the wiper.
•
The first few prints of a job have oil or dirt on them.
•
An interval of 80,000 to 100,000 prints are made. (The number
of prints made is tracked by the billing meter, which you can
view through the Administration pull-down menu on the IPS
main window.)
Your service representative usually replaces the pressure roll wiper
for the DocuPrint System. However, you might choose to replace the
pressure roll wiper yourself if you have been previously trained in this
procedure.
To replace the wiper:
1. Power off the printer.
2. Open the printer doors and locate the fuser drawer.
3. Move the green lever (A) counter-clockwise, grasp the green
handle on the fuser drawer, (B) and pull it out until it stops.
B