8 - 4
W - Target White Value
Sets the target for the median grayscale value in the captured image. For
capturing close-up images of high contrast documents, a lower setting,
such as 75, is recommended. Higher settings result in longer exposure
times and brighter images, but if the setting is too high, the image may be
overexposed. Target White Value is only available when using Photo Style
(1P).
(Default = 125)
nW Range: 0 - 255
D - Delta for Acceptance
This sets the allowable range for the white value setting (see
). Delta is only available when using Photo Style (1P).
(Default = 25)
nD Range: 0 - 255
U - Update Tries
This sets the maximum number of frames the scanner should take to reach
the
. Update Tries is only available when using
Photo Style (1P).
(Default = 6)
nU Range: 0 - 10
% - Target Set Point Percentage
Sets the target point for the light and dark values in the captured image. A
setting of 75% means 75% of the pixels are at or below the target white
value, and 25% of the pixels are above the target white value. Altering this
setting from the default is not recommended under normal circumstances.
To alter grayscale values,
(Default
= 50)
n% Range: 1 - 99
Example of White
Value at 75W:
Example of White
Value at 125W:
Example of White
Value at 200W:
Example of Target
Set Point
Percentage at 97%:
Example of Target
Set Point
Percentage at 40%:
Example of Target
Set Point
Percentage at 50%:
Summary of Contents for 1900
Page 1: ...Xenon 1900 1910 Xenon 1902 1912 Granit 1910i 1911i Area Imaging Scanner User s Guide...
Page 20: ......
Page 32: ...xii...
Page 72: ...2 24 1200 2400 4800 9600 19200 38400 57 600 115 200...
Page 118: ...3 40...
Page 148: ...4 30...
Page 174: ...6 20...
Page 238: ...7 64...
Page 258: ...8 20...
Page 262: ...9 4...
Page 268: ...10 6...
Page 312: ...11 44...
Page 350: ...A 14...
Page 353: ...Sample Symbols Aztec MaxiCode Micro PDF417 Package Label Test Message Test Message...