3 - 34
Auto Reconnect Mode
Auto Reconnect controls whether or not the scanner automatically begins
the relink process when a loss of connection is detected. When the
Auto
Reconnect On
bar code is scanned, the scanner begins the relink process
immediately, without user intervention.
Default = Auto Reconnect On.
Note: If you are connecting to a Bluetooth Interface Module, set Auto
Reconnect to Off.
The table below shows the results of the Auto Reconnect On and Off set-
tings:
Event
Auto Reconnect On
Auto Reconnect Off
Scanner out of
range
Relink occurs
automatically. If
maximum number of link
attempts is
unsuccessful, then the
scanner must be
relinked by either pulling
the trigger, placing the
scanner in the base, or
scanning the Access
Point linking bar code.
(See
The scanner is
relinked by pulling the
trigger, or scanning
the Access Point
linking bar code.
Base or Access
point reset
(firmware upgrade
or power cycle)
Scanner behaves as if
out of range.
No attempt to relink
made while base or
Access Point is
powered off. Trigger
must be pulled to
initiate relinking.
* Auto Reconnect On
Auto Reconnect Off
Summary of Contents for 1900
Page 1: ...Xenon 1900 1910 Xenon 1902 1912 Granit 1910i 1911i Area Imaging Scanner User s Guide...
Page 20: ......
Page 32: ...xii...
Page 72: ...2 24 1200 2400 4800 9600 19200 38400 57 600 115 200...
Page 118: ...3 40...
Page 148: ...4 30...
Page 174: ...6 20...
Page 238: ...7 64...
Page 258: ...8 20...
Page 262: ...9 4...
Page 268: ...10 6...
Page 312: ...11 44...
Page 350: ...A 14...
Page 353: ...Sample Symbols Aztec MaxiCode Micro PDF417 Package Label Test Message Test Message...