57
RTP
Port Range:
The RTP Port range defines the range of ports from which the video/audio
ports are automatically selected. This feature is useful if the camera is connected to a NAT
router with manually configured port mapping.
NOTE
Limit the range of ports permitted for RTP unicast/multicast by entering the Start port and
End port in the provided fields.
Start port:
The Start port can be entered in the range 1024-65532. The default setting is
5008.
End port:
The End port can be entered in the range 1024-65532. The default setting is
50999.
NOTE
The video/audio ports entered here must be even values.
Multicast-Stream1~3:
Only IP addresses within certain ranges can be used for multicasting. The camera has been
pre-configured with addresses from these ranges, and does not normally need to be
reconfigured. If an address does need to be changed, please contact your network
Summary of Contents for XIPDC1080-4e
Page 1: ...1 Full HD Network Camera USER MANUAL...
Page 5: ...5 Physical Dimensions unit mm Plastic internal dome Vandal dome housing...
Page 6: ...6 Explanation for Each Function Plastic internal dome Vandal dome housing...
Page 52: ...52 ONVIF To use ONVIF Authentication Please check the Enable WS security...