23
22
The BlaCK eanX is equipped with a water sensor that is activated automati-
cally once in contact with water; therefore, it does not require to be turned on
manually before entering the water. It enters diving mode at a depth of 1.5m.
water sensor was calibrated to detect both salt and fresh water. However, in
particular environments (e.g. mountain lakes) water conductivity is too low for
the sensor to detect it. In such situations, the device will activate through the
pressure sensor at depth of 0.5m.
For the first 30 seconds after entering the diving mode, in a place where
normally no-decompression limit (nDl) is displayed, the device displays the name
of the gas which is active at the start of the dive (primary gas). It’s your obliga-
tion to verify whether this is the same gas that is currently used.
DIVING – DIVE START 1/2
If the battery charge level totals less than 20%, device will not
enter the diving mode and will display message ‘Do not Dive’.
always check the battery charge level before entering the water.
even though BlaCK activates automatically, before entering
the water always make sure that the device is switched on and
operates correctly.
DIVING – DIVE START 2/2
The BlaCK eanX activates depth and time measuring mode
after entering the diving mode. The max. depth for the device
to activate measuring totals 1.5m.
attention! The adv.eanx mode is recommened only for advanced
users, who know and understand Gradient Factors. Other users are
recommened to use eanx mode, which provides the same function-
ality, but the conservatism is set using three preset values.
attention! If you begin the dive breathing the gas other than
the primary, remember to switch the gas immediately after
start descending. If you fail to do it, the device will include in
the calculations another gas than the one you are actually
breathing, which as a result may lead to incorrect calculation of
decompression stops and no-decompression limits.