XE210C Hydraulic Excavator
Operating and Maintenance Manual
135
b)
Electric system
Table 2-10 Trouble shooting of electric system
Trouble
Cause
Remedy
Slow starting of engine
Current leakage of battery or it can’t hold
the charge capacity.
Replace the battery.
“Draggle” of starting motor
Contact with the assigned dealer of XEM
excavator.
Low voltage of battery
Charge or replace battery
The starting motor continues to
run after starting the engine.
Trouble of starting relay
Contact with the assigned dealer of XEM
excavator.
Suction of starting motor magnetic coil
Contact with the assigned dealer of XEM
excavator.
The starting motor can’t be disconnected.
Contact with the assigned dealer of XEM
excavator.
Trouble of key switch
Contact with the assigned dealer of XEM
excavator.
The charging indicator goes on
during the running of engine.
Loosening or slipping of AC generator
belt
Check the belt, if slipped, replace; if loose,
tension.
Low speed of engine
Adjust the speed to the specified value.
Attached accessories cause the electric
overload.
Remove the attached accessories or install
higher-output AC generator.
Loosening of battery, grounding steel
strip, starting motor or AC generator,
corrosion of electric connection
Check,
clean
or
tighten
the
electric
connection.
Low voltage of battery
Charge or replace the battery.
AC generator trouble
Contact with the assigned dealer of XEM
excavator.
Trouble of monitor
Contact with the assigned dealer of XEM
excavator.
Fracas of AC generator
Worn driving belt
Replace the belt.
Worn belt pulley
Replace the belt pulley and belt.
Improper adjustment of belt pulley
Adjust the installation of AC generator
Trouble of AC generator bearing
Loosen the belt of AC generator, and turn the
belt pulley by hands. In case of feeling
difficult to turn, repair AC generator.
Indicator of monitor can’t go on.
Trouble of monitor
Contact with the assigned dealer of XEM
excavator.
Trouble of electric wiring
Contact with the assigned dealer of XEM
excavator.
Damaged fuse
Replace the fuse.
Trouble of sensor.
Check the sensor.
The cooling water thermometer
fails to work.
Damaged fuse
Replace the fuse.
Trouble of thermometer
Contact with the assigned dealer of XEM
excavator.
Trouble of temperature sensor
Check
the
sensor
of
cooling
water
thermometer.
Trouble of electric circuit
Contact with the assigned dealer of XEM
excavator.
The automatic idling indicator
goes out.
Damaged fuse
Replace the fuse.
Trouble of automatic idling switch
Contact with the assigned dealer of XEM
excavator.