15
Front Panel Operation - Weld Program Selection
Razor
32OAC/DC
TIG-MMA
Turn the Encoder to set
the Up Slope value
(Range is 0-15 Sec)
Turn the Encoder to set
the Peak Amp value
(Range is 10-320A)
Turn the Encoder to set
the Base Amp value
(Range is 5-320A)
Turn the Encoder to set
the Down Slope time
(Range is 0-15 Sec)
Turn the Encoder to set
the Finish Amp value
(Range is 10-200A)
Peak Amp: Select by turning the encoder to cycle
through to illuminate the Peak Amp icon.
Base Amp: Select by turning the encoder to cycle
through to illuminate the Base Amp icon.
Base Amp: Select by turning the encoder to cycle
through to illuminate the Down Slope icon.
Finish Amp: Select by turning the encoder knob to
cycle through to illuminate the Finish Amp icon.
The setting shows on the digi-
tal display. It is the amount of
amps the machine will deliver
at the start of the weld.
The setting shows on the digital
display. It is the maximum am-
perage the machine will deliver
during welding
The setting shows on the
digital display. It is the set
amperage the machine will
deliver during the Base Amp
period of the pulse cycle.
The setting shows on the digi-
tal display. It is the time taken
for the welding amps to drop
down to the finish amperage.
The setting shows on the digital
display. It is the amperage the
machine will deliver at the finish
of the welding sequence.
Up Slope Time -
Provides selection for the amount of amps required at the start of the weld.
Peak Amp -
Provides selection for the Maximum Welding Amperage required during welding.
Base Amp -
Provides selection for the Base Amperage during the Pulse Welding cycle.
Down Slope Time -
Sets the transition time from Welding Amperage to Finish Amperage
Finish Amp -
Provides selection for the amount of amperage required at the end of the weld.
Push the Encoder to
lock the icon ready for
adjustment.
Push the Encoder to
lock the icon ready for
adjustment.
Push the Encoder to
lock the icon ready for
adjustment.
Push the Encoder to
lock the icon ready for
adjustment.
Push the Encoder to
lock the icon ready for
adjustment.
Turn the Encoder to set
the Finish Amp value
(Range is 10-200A)
Post Gas Time: Select by turning the encoder
knob to cycle through to illuminate the Post Gas
Timer icon.
The value selected shows on the
digital display. It is the length of
time the gas will flow after the arc
is finished.
Post Gas Timer -
Provides selection for continued gas flow time at the end of the welding after the arc is out.
Push the Encoder to
lock the icon ready for
adjustment.
Up Slope Time: Select by pushing the encoder to
cycle through to illuminate the Up Slope icon.
Summary of Contents for RazorWeld Razor TIG320 ACDC
Page 7: ...7 Electrical Schematic Diagram Razor32OAC DC TIG MMA...
Page 54: ...54 NOTES...
Page 55: ...55 NOTES...