background image

19

To use the DC appliance outlet or USB 

without the generator being operated

The 12 volt appliance outlet and or the USB outlet can be 

used if a 12V car battery is connected to the charging socket 

as described in the section  “

To use the battery charging 

socket

”. An appliance connected to the 12V Appliance 

socket or to the USB socket will operated using the power 

from the car battery. The generator does not need to be 

operating for this to function, provided the lead acid car 

battery has sufficient charge.
It is recommended to charge the lead acid car battery first.
Remove the battery from the car, boat or any other device. 

The battery MUST be totally isolated from any other circuitry.
1. Connect the supplied 

cables to the battery 

terminals. Using the colour 

coding, the clamps on the 

cable MUST be connected 

as follows. RED clip to the 

+ Positive terminal on the 

battery, and BLACK clip 

to the – negative terminal 

on the battery (Fig. S).  

After connection to the battery, RECHECK to ensure the 

connections are as above.

2. Start the generator and allow the generator to warm up.
3. Insert the plug on the opposite end of the cable connected 

to the battery into the battery charging socket.

4. Check the DC reset button is pressed inward.
After charging the battery, the generator can be stopped  

and at any time, the appliance socket  can be used  or the 

USB outlet be used while the lead acid car battery is still 

connected.

Note.

 Ensure the Appliance plug connected to the appliance 

socket in the generator is fitted with a fuse.
Using the lead acid car battery as the power source, the 

following ratings should not be exceeded.

12V appliance socket:

 10 amp.

5 V USB:

 1 amp.

Both sockets can be used at the one time.

Note.

 A safety fuse is fitted to the internal wiring of the 

generator to prevent overloading of this feature.
Always ensure any plug fitted to the appliance socket is 

fitted with a fuse NOT exceeding 10A.

WARNING.

  The battery gives off explosive gases; keep sparks, 

flames and cigarettes away.

  Provide adequate ventilation when charging or using 

batteries in an enclosed space.

  The battery contains sulphuric acid (electrolyte). Contact 

with skin or eyes may cause severe burns. Wear 

protective clothing and a face shield.

  If electrolyte gets on your skin, flush with water.

  If electrolyte gets in your eyes, flush with water for at  

least 15 minutes and call a physician immediately. 

  Electrolyte is poisonous. If swallowed seek urgent  

medical attention.

  To prevent the possibility of creating a spark near the 

battery, connect charging cables first to the battery, then 

to the generator. Disconnect cables first at the generator.

DC overload cut out

IMPORTANT.

 Exceeding the rated capacity of your 

generator can result in serious damage to your generator 

and connected apparatus.
1. The DC circuit has a circuit breaker to protect the 

generator from over loading.

2. If the circuit breaker trips, unplug all electrical apparatus 

from the generator.

3. Let the overload cut out switch cool down.
4. Press the DC reset button (5). Commence to start your  

generator accordingly.

S

–      +

Summary of Contents for X2300KS

Page 1: ...INSTRUCTION MANUAL X2300KS 254 2173 2300W PETROL GENERATOR...

Page 2: ...utlet 20 To use the DC appliance outlet or USB without the generator being operated 21 DC overload cut out 21 Carbon build up 22 Generator maintenance 22 Periodic maintenance 23 Storage 24 Spark plugs...

Page 3: ...ax 5 A USB output 5V Max 1 Amp Motor 5 5HP 4 stroke No load speed 3000 min 1 Fuel tank capacity 15L Fuel type Unleaded Oil type 4 Stroke Net weight 38 5kg Electric start Yes Items required for operati...

Page 4: ...ntangled cords increase the risk of electric shock When operating a power tool outdoors use an outdoor extension cord suitable for outdoor use Use of a cord suitable for outdoor use reduces the risk o...

Page 5: ...in the hands of untrained users Maintain power tools Check for misalignment or binding of moving parts breakage of parts and any other condition that may affect the power tool s operation If damaged...

Page 6: ...charge conductive surfaces in contact with the generator Place generator on low conductivity surface such as a concrete slab ALWAYS operate generator a minimum of 2 meters from any conductive surface...

Page 7: ...ngine speed has been factory set to provide safe operation Tampering with the engine speed adjustment could result in overheating of attachments and could cause a fire Never attempt to speed up the en...

Page 8: ...rator in clean dry well ventilated area Never operate unit in enclosed areas such as garages basements storage sheds or in any location occupied by humans or animals Keep children pets and others away...

Page 9: ...ng operation These parts are covered by guarding to prevent injury Never operate generator with guarding or cover plates removed Avoid wearing loose fitting clothing or jewellery which could be caught...

Page 10: ...ce Ensure the generator has oil Before commencing the generator ensure that the unit has been filled with SAE 30 4 stroke oil Never fill fuel tank indoors Never fill fuel tank when engine is running o...

Page 11: ...tery charging socket 10 DC appliance socket 11 USB power outlet 12 Electric start key start 13 Air filter cover 14 Choke lever 15 Spark plug 16 Fuel drain 17 Muffler 18 Exhaust spark arrestor 19 DC pl...

Page 12: ...nverter controls It is also recommended to use a surge protector on the outlets of the generators Preparing the generator It is important to check the generator before you commence operating the unit...

Page 13: ...check the oil level each time the generator is used Battery start connection When unpacked this generator is not fully connected to the starting battery 22 and will require the negative wire to be co...

Page 14: ...on Fig G Note When the motor is started for the very first time it may require a number of attempts to start until the fuel has travelled from the tank to the motor 5 Once you hear the motor operating...

Page 15: ...nerator 2 Turn the key start ignition 12 to the OFF position Fig J1 3 Turn the fuel lever anti clockwise to the off position Connecting apparatus to the generator Start the generator and allow the gen...

Page 16: ...of a some failed appliances and assisting to protect people against an electric shock Safety switch tripping If the circuit breaker 4 has tripped and cuts off the power it may be due to substantial o...

Page 17: ...e button to reset Note The 12V appliance socket can also be used with the 240V AC outlets being used To use the battery charging outlet The generator is fitted with a socket outlet specifically for co...

Page 18: ...if the battery was originally in a low level of charge the battery will take many hours to recharge fully The time frame will depend on the size of the battery As a guide a standard car battery of aro...

Page 19: ...the Appliance plug connected to the appliance socket in the generator is fitted with a fuse Using the lead acid car battery as the power source the following ratings should not be exceeded 12V applian...

Page 20: ...used for 4 hours run the generator for 1 hour at around 75 of rating This is only required if the generator has been used for less than 50 or rated load If the generator is being used for solely char...

Page 21: ...ace if necessary Valve clearance Check and adjust when engine is cold Fuel line Check fuel hose for crack or damage Replace if necessary Exhaust system Check for leakage Retighten or replace gasket if...

Page 22: ...K RN11YC Champion WR6DC Bosch Model G1100KU W7RBC Bosch RL87BC Champion BPR7HS NGK Engine oil replacement 1 Place the generator on a level surface and warm up the engine for several minutes The stop t...

Page 23: ...ter 24 prevents any dirt in the fuel from entering the fuel system The procedure for removing this filter in order to replace or clean it is given below Note the following procedure should be performe...

Page 24: ...here are no leaks between the tap and the tank and with the fuel tap turned on ensure there are no leaks where the fuel hose is fitted to the outlet of the tap Cleaning 1 Keep your machine clean The o...

Page 25: ...en fuel shut off valve 7 Unit loaded during start up 7 Remove load from unit 8 Spark plug wire loose 8 Attach wire to spark plug No electrical output 1 Faulty receptacle 1 Have service centre replace...

Page 26: ...loaded 1 Reduce load 2 Insufficient ventilation 2 Move to adequate supply of fresh air No DC Output 1 DC circuit overloaded 1a Remove DC load and reset cut out after 5 min 1b If Battery charging check...

Page 27: ......