background image

10

Additional safety rules for generators

 

Do not operate in a hazardous location.

 Such areas 

include where there is a risk of explosion of petrol fumes, 

leaking gas or explosive dust.

 

Do not operate in a confined area. 

Exhaust gases, 

smoke or fumes could reach dangerous concentrations.

 

The output of this generator is potentially lethal.

 The 

generator should not be connected to a fixed electrical 

installation except by an appropriately licensed person.

 

Protect your generator. 

This generator is NOT 

WEATHERPROOF and should not be exposed to direct 

sunlight, high ambient temperature and damp, wet or  

high humidity conditions.

 

Do not smoke while refuelling.

 This is potentially 

dangerous as it may ignite the fuel and cause an explosion.

 

Take care not to spill fuel.

 When refuelling the generator 

ensure that the motor has been switched off. Prevent the 

spilling of fuel as this may also ignite with the hot motor. 

Never refuel whilst the engine running.

 

Be careful where you store the generator. 

Store the 

generator in a dry area away from inflammable liquids.

 

Keep your distance.

 The generator emits exhaust 

fumes. As a safety precaution do not stand close to the 

unit whilst it is in operation. Ensure bystanders also keep 

their distance.

 

Ensure the generator has oil.

 Before commencing 

the generator, ensure that the unit has been filled with 

SAE#30 4 stroke oil. 

 

Never fill fuel tank indoors.

 Never fill fuel tank when 

engine is running or hot. Do not smoke when filling  

fuel tank.

 

Never refuel when the generator is running. 

Switch the 

generator to the off position prior to removing the fuel cap 

and refuelling.

 

Engine speed has been factory set to provide safe 

operation.

 Tampering with the engine speed adjustment 

could result in overheating of attachments and could 

cause a fire. Never attempt to “speed-up” the engine to 

obtain more performance. Both the output voltage and 

frequency will be thrown out of standard by this practice, 

endangering attachments and the user.

You MUST unplug any load from the generator before 

starting and stopping to prevent permanent damage to 

any appliances.
WARNING

  Persons who are fitted with a heart pacemaker,  

or similar medical conditions should take care when  

using this device, even the extra low voltage of the battery 

charging output should not be handled by a person with 

medical conditions as or similar to the above.

Unpacking

Due to modern mass production techniques, it is unlikely 

that your Xceed generator is faulty or that a part is missing. 

If you find anything wrong, do not operate the tool until the 

parts have been replaced or the fault has been rectified. 

Failure to do so could result in serious personal injury.

Summary of Contents for X2300KS

Page 1: ...INSTRUCTION MANUAL X2300KS 254 2173 2300W PETROL GENERATOR...

Page 2: ...utlet 20 To use the DC appliance outlet or USB without the generator being operated 21 DC overload cut out 21 Carbon build up 22 Generator maintenance 22 Periodic maintenance 23 Storage 24 Spark plugs...

Page 3: ...ax 5 A USB output 5V Max 1 Amp Motor 5 5HP 4 stroke No load speed 3000 min 1 Fuel tank capacity 15L Fuel type Unleaded Oil type 4 Stroke Net weight 38 5kg Electric start Yes Items required for operati...

Page 4: ...ntangled cords increase the risk of electric shock When operating a power tool outdoors use an outdoor extension cord suitable for outdoor use Use of a cord suitable for outdoor use reduces the risk o...

Page 5: ...in the hands of untrained users Maintain power tools Check for misalignment or binding of moving parts breakage of parts and any other condition that may affect the power tool s operation If damaged...

Page 6: ...charge conductive surfaces in contact with the generator Place generator on low conductivity surface such as a concrete slab ALWAYS operate generator a minimum of 2 meters from any conductive surface...

Page 7: ...ngine speed has been factory set to provide safe operation Tampering with the engine speed adjustment could result in overheating of attachments and could cause a fire Never attempt to speed up the en...

Page 8: ...rator in clean dry well ventilated area Never operate unit in enclosed areas such as garages basements storage sheds or in any location occupied by humans or animals Keep children pets and others away...

Page 9: ...ng operation These parts are covered by guarding to prevent injury Never operate generator with guarding or cover plates removed Avoid wearing loose fitting clothing or jewellery which could be caught...

Page 10: ...ce Ensure the generator has oil Before commencing the generator ensure that the unit has been filled with SAE 30 4 stroke oil Never fill fuel tank indoors Never fill fuel tank when engine is running o...

Page 11: ...tery charging socket 10 DC appliance socket 11 USB power outlet 12 Electric start key start 13 Air filter cover 14 Choke lever 15 Spark plug 16 Fuel drain 17 Muffler 18 Exhaust spark arrestor 19 DC pl...

Page 12: ...nverter controls It is also recommended to use a surge protector on the outlets of the generators Preparing the generator It is important to check the generator before you commence operating the unit...

Page 13: ...check the oil level each time the generator is used Battery start connection When unpacked this generator is not fully connected to the starting battery 22 and will require the negative wire to be co...

Page 14: ...on Fig G Note When the motor is started for the very first time it may require a number of attempts to start until the fuel has travelled from the tank to the motor 5 Once you hear the motor operating...

Page 15: ...nerator 2 Turn the key start ignition 12 to the OFF position Fig J1 3 Turn the fuel lever anti clockwise to the off position Connecting apparatus to the generator Start the generator and allow the gen...

Page 16: ...of a some failed appliances and assisting to protect people against an electric shock Safety switch tripping If the circuit breaker 4 has tripped and cuts off the power it may be due to substantial o...

Page 17: ...e button to reset Note The 12V appliance socket can also be used with the 240V AC outlets being used To use the battery charging outlet The generator is fitted with a socket outlet specifically for co...

Page 18: ...if the battery was originally in a low level of charge the battery will take many hours to recharge fully The time frame will depend on the size of the battery As a guide a standard car battery of aro...

Page 19: ...the Appliance plug connected to the appliance socket in the generator is fitted with a fuse Using the lead acid car battery as the power source the following ratings should not be exceeded 12V applian...

Page 20: ...used for 4 hours run the generator for 1 hour at around 75 of rating This is only required if the generator has been used for less than 50 or rated load If the generator is being used for solely char...

Page 21: ...ace if necessary Valve clearance Check and adjust when engine is cold Fuel line Check fuel hose for crack or damage Replace if necessary Exhaust system Check for leakage Retighten or replace gasket if...

Page 22: ...K RN11YC Champion WR6DC Bosch Model G1100KU W7RBC Bosch RL87BC Champion BPR7HS NGK Engine oil replacement 1 Place the generator on a level surface and warm up the engine for several minutes The stop t...

Page 23: ...ter 24 prevents any dirt in the fuel from entering the fuel system The procedure for removing this filter in order to replace or clean it is given below Note the following procedure should be performe...

Page 24: ...here are no leaks between the tap and the tank and with the fuel tap turned on ensure there are no leaks where the fuel hose is fitted to the outlet of the tap Cleaning 1 Keep your machine clean The o...

Page 25: ...en fuel shut off valve 7 Unit loaded during start up 7 Remove load from unit 8 Spark plug wire loose 8 Attach wire to spark plug No electrical output 1 Faulty receptacle 1 Have service centre replace...

Page 26: ...loaded 1 Reduce load 2 Insufficient ventilation 2 Move to adequate supply of fresh air No DC Output 1 DC circuit overloaded 1a Remove DC load and reset cut out after 5 min 1b If Battery charging check...

Page 27: ......