Analog Programming (APG) and Isolated Analog Programming (ISOL)
4-22
975-0200-01-01
Voltage-Controlled Voltage ISOL Setup
Activating ISOL Programming Voltage Mode
To activate ISOL programming voltage mode with an external
voltage source:
1. Turn the mode control knob to the VAP position or press the Rotary
knob/Enter button if the control knob is already at the VAP position.
WAPr
is displayed on the output voltage display.
2. Turn Rotary knob/Enter button to select
U IS
(voltage source from
isolated connector).
3. Press the Rotary knob/Enter button to commit the selected mode.
LE U
is displayed on the output voltage display.
4. Select the input source level using the Rotary knob/Enter button.
5. Once the desired level has been selected, press the Rotary knob/
Enter button to commit the change.
The display will return to the normal display.
Deactivating ISOL Voltage Mode
To deactivate the ISOL voltage mode:
1. Turn the mode control knob to the VAP position or press the Rotary
knob/Enter button if the control knob is already at the VAP position.
2.
UAPr
is displayed on the output voltage display.
3. Turn the Rotary knob/Enter button to select
nonE
.
4. Press the Rotary knob/Enter button to commit the change.
The display will return to the normal display.
Query for ISOL Voltage Input Level
To query for ISOL voltage input level from non-isolated input:
1. Turn the mode control knob to the VAP position or press the Rotary
knob/Enter button if the control knob is already at the VAP position.
UAPr
is displayed on the output voltage display.
Summary of Contents for XTR 100-17
Page 2: ......
Page 3: ...XTR 850 Watt and 1700 Watt Series Programmable DC Power Supply Operating Manual...
Page 6: ......
Page 18: ...xvi...
Page 48: ...2 18...
Page 122: ...4 30...
Page 208: ...6 20...
Page 244: ...A 36...
Page 250: ...B 6...
Page 264: ...C 14...
Page 272: ...IX 4...
Page 273: ......