Summary of Contents for Xantrex PRO XM 1000

Page 1: ...Inverter XM 1000 and XM 1800 Owner s Guide 975 0263 01 01 REV B Printed in China t 1 800 670 0707 toll free in North America 1 360 925 5097 direct f 1 360 925 5143 direct e CustomerService xantrex com www xantrex com ...

Page 2: ...Xantrex PRO Inverter Owner s Guide ...

Page 3: ... herein for identification purposes only Notice of Copyright Xantrex PRO Inverter Owner s Guide December 2005 Xantrex International All rights reserved Disclaimer UNLESS SPECIFICALLY AGREED TO IN WRITING XANTREX TECHNOLOGY INC XANTREX a MAKES NO WARRANTY AS TO THE ACCURACY SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION b ASSUMES NO R...

Page 4: ...dures for installing the inverter as well as information about operating and troubleshooting the installation It does not provide details about particular brands of batteries You need to consult individual battery manufacturers for this information Audience The Guide is intended for anyone who needs to install and operate the Xantrex PRO Inverter Because installation requires compliance with appli...

Page 5: ...logy Inc and its products and services at www xantrex com WARNING Warnings identify conditions that could result in personal injury or loss of life CAUTION Cautions identify conditions or practices that could result in damage to the unit or other equipment Important These notes describe things which are important for you to know but not as serious as a caution or warning ...

Page 6: ...rter with damaged or substandard wiring 5 Do not operate the inverter if it has received a sharp blow been dropped or otherwise damaged in any way If the inverter is damaged see the Warranty section 6 Do not disassemble the inverter It contains no user serviceable parts See Warranty for instructions on obtaining service Attempting to service the inverter yourself may result in a risk of electrical...

Page 7: ...mpartments containing batteries or flammable materials or in locations that require ignition protected equipment This includes any space containing gasoline powered machinery fuel tanks as well as joints fittings or other connections between components of the fuel system 3 To reduce the risk of battery explosion follow these instructions and those published by the battery manufacturer and the manu...

Page 8: ...ies produce a short circuit current high enough to weld metal to skin causing a severe burn 6 Have someone within range of your voice or close enough to come to your aid when you work near a lead acid battery 7 Have plenty of fresh water and soap nearby in case battery acid contacts skin clothing or eyes 8 Wear complete eye protection and clothing protection Avoid touching your eyes while working ...

Page 9: ...ttery operated appliances like flashlights razors and night lights that can be plugged directly into an AC receptacle to recharge Some chargers for battery packs used in power hand tools These affected chargers display a warning label stating that dangerous voltages are present at the battery terminals If you are unsure about using your rechargeable appliance with the inverter contact the equipmen...

Page 10: ...3 4 Choosing an Appropriate Location 3 5 Calculating Cable Sizes 3 6 Calculating Size of DC Input Cables 3 6 Sizing the Chassis Ground Cable 3 7 Calculating Fuse Circuit Breaker Size 3 8 Installing the XM Series Inverter 3 9 Safety Instructions 3 9 Installation Tools and Materials 3 9 Overview of Installation Steps 3 11 Mounting the Inverter 3 11 Connecting the Chassis Ground 3 12 Grounding Locati...

Page 11: ... Checking Battery Status 4 4 Checking Output Power 4 4 Operating Several Loads at Once 4 4 Turning the Inverter Off When Not Used 4 4 Operating Limits 4 5 Power Output 4 5 Input Voltage 4 5 Inverter Loads 4 6 Overload Conditions 4 6 High Surge Loads 4 6 Trouble Loads 4 6 Over temperature Conditions 4 7 Routine Maintenance 4 7 XM Series Inverter Unit 4 7 Batteries 4 7 5 Troubleshooting Common Probl...

Page 12: ... Example B 4 Battery Sizing Worksheet B 5 Using Multiple Batteries B 6 Two Batteries Connected In Parallel B 6 Two Separate Battery Banks B 6 Battery Tips B 7 C Alternators and Charging Systems Charging System Requirements C 1 Charging With an Engine Alternator C 2 Using a Standard Vehicle Alternator C 2 Using an Alternator Controller C 2 Using a High Output Alternator C 2 Charging From AC Power C...

Page 13: ...xii ...

Page 14: ...rowaves TVs VCRs and midsized power tools The XM Series Inverter s high surge capability lets you handle many hard to start loads including large TVs and small refrigerators The built in transfer switch automatically transfers between inverter power and incoming AC power shore power to ensure power is always available A built in 15 A supplementary circuit breaker protects the XM Series Inverter fr...

Page 15: ...e input voltage rises to 15 5 V or more Overload alarm Alerts you if the loads connected to the XM Series Inverter are close to the inverter s operating limits Overload shutdown Shuts the XM Series Inverter down automatically if the loads connected to the inverter exceed the inverter s operating limits or if a short circuit is detected in the circuitry connected to the inverter s output Over tempe...

Page 16: ...verter inverter Two M8 lock washers on the DC input cable terminals Two M8 nuts on the DC input cable terminals Two strain reliefs for AC input and output wiring Two rubberized input terminal covers Owner s Guide If any of these materials are missing or are unsatisfactory in any way please contact Customer Service Contact information is available on page WA 1 As soon as you unpack your inverter be...

Page 17: ... existing AC power system 3 Knockouts for routing AC input and output wiring in hardwired installations 4 Mounting flange allows you to mount the inverter permanently Feature Description 1 15 A supplementary circuit breaker provides overload protection for the GFCI receptacles In a hardwired installation the supplementary circuit breaker does not protect output wiring 2 Grounding stud connects to ...

Page 18: ... of the battery 2 Ventilation opening must not be obstructed for the proper operation of the cooling fan and inverter When the inverter is mounted the ventilation opening must not point up or down 3 Positive DC cabling terminal connects to the cable connected to the positive terminal of the battery 4 Serial number of your unit 4 1 2 3 XM 1000 shown ...

Page 19: ...2 4 ...

Page 20: ...r and then design a power system that will give you maximum performance The more thorough your planning the better your power needs will be met In particular you will need to Be aware of installation codes Calculate your battery requirements Choose an effective charging system Choose an appropriate location Calculate the DC and AC cable sizes Select the correct fuses or circuit breakers Study Figu...

Page 21: ...OUND TO VEHICLE CHASSIS DISCONNECT SWITCH FUSE OR CIRCUIT BREAKER DEEP CYCLE AUXILIARY BATTERY DEEP CYCLE AUXILIARY BATTERY GROUND TO VEHICLE CHASSIS VEHICLE STARTING BATTERY GROUND TO VEHICLE CHASSIS TO VEHICLE TO DC LOADS ISOLATOR FROM ALTERNATOR CHARGER FUSE OR CIRCUIT BREAKER ON OFF ...

Page 22: ...E BATTERY ISOLATOR FROM ALTERNATOR CHARGER GROUND TO VEHICLE CHASSIS VEHICLE STARTING BATTERY DISCONNECT BATTERY SELECTOR SWITCH DEEP CYCLE BATTERY DEEP CYCLE BATTERY DEEP CYCLE BATTERY DEEP CYCLE BATTERY BATTERY SELECTOR SWITCH TO DC LOADS ALL OFF 2 1 ALL OFF 2 1 FUSE OR CIRCUIT BREAKER FUSE OR CIRCUIT BREAKER FUSE OR CIRCUIT BREAKER FUSE OR CIRCUIT BREAKER ...

Page 23: ...ow much power you will be using you can determine how much battery capacity you need Xantrex recommends that you purchase as much battery capacity as possible Consult Appendix B Battery Types for a detailed explanation of how to determine the appropriate number and size of batteries for your needs Choosing an Effective Charging System The charging system must be appropriate for your particular ins...

Page 24: ...bient air temperature should be between 32 ºF and 105 ºF 0 ºC and 40 ºC the cooler the better within this range Ventilated Allow at least 3 inches 7 5 cm of clearance around the inverter for air flow Ensure that the ventilation openings on the DC end of the unit are not obstructed Safe Do not install the inverter in the same compartment as batteries or in any compartment capable of storing flammab...

Page 25: ...chassis ground screw on the inverter s DC panel See Figure 3 3 on page 3 12 Calculating Size of DC Input Cables Refer to Table 3 1 to plan the DC input cabling for your application Use only cable rated for 90 C Oil resistant cable is recommended Keep all cables as short as possible and ensure that each cable between the inverter and the battery is no longer than 5 feet 1 5 m Do not use aluminum ca...

Page 26: ...ay Minimum Cable Size Maximum Battery Fuse Size XM 1000 Less than 5 feet 1 5 m No 2 AWG 150 ADC XM 1800 Less than 5 feet 1 5 m No 2 0 AWG 250 ADC Note Never use a cable longer than 5 feet 1 5 m with the XM Series Inverter Appropriately sized 90 C cable can be bought at a welding supply house or a marine supply store Table 3 2 Recommended Chassis Ground Cable size Application Minimum chassis ground...

Page 27: ...nt rating is 1000 A If you are powering your inverter with two 6 V batteries connected in series and each battery has a short circuit current rating of 500 A the total short circuit current rating is 500 A 2 Once you have determined the total short circuit current rating of your batteries pick the fuse circuit breaker s interrupt capacity based on the short circuit current calculated in step 1 3 P...

Page 28: ...u have the knowledge tools and experience to do a safe job Because installation requires compliance with various codes installers should be certified technicians or electricians Read and follow all Warnings and Cautions in this chapter Installation Tools and Materials Tools Wire stripper Wrench for DC terminals and ground stud Screwdrivers 1 8 slot head and Phillips Crimping tool for fastening lug...

Page 29: ...age 3 7 p Ring terminal appropriately sized to connect copper cable to chassis ground stud that meets the following specifications 8 M4 stud UL CSA approved copper tin plated p Battery isolator if connecting to a multiple battery system p Disconnect battery selector switch p Optional 2 15 A circuit breakers XM 1000 or 2 20 A circuit breakers XM 1800 used for hard wiring the AC input and AC output ...

Page 30: ...ou can mount the inverter horizontally or vertically See Choosing an Appropriate Location on page 3 5 To mount the XM Series Inverter 1 Select an appropriate mounting location and orientation The XM Series Inverter must be oriented in one of the following ways On or under a horizontal surface Horizontally on a vertical surface The ventilation opening on the DC end must not point up or down 2 Use t...

Page 31: ...s ground stud to a grounding point usually the vehicle s chassis using recommended copper wire if insulated then green insulation with or without one or more yellow stripes or larger For recommended chassis ground cable size see Sizing the Chassis Ground Cable on page 3 7 WARNING Shock hazard Never operate the XM Series Inverter without properly connecting the chassis ground An electrical shock ha...

Page 32: ... stud nut and star washer 2 Strip 1 2 inch 13 mm to 3 4 inch 19 mm of insulation from the end of the cable 3 Attach the ring connector that will join the cable to the chassis ground stud The connector you use must create a permanent low resistance connection See Materials on page 3 10 4 Fit the ring connector and star washer over the stud The ring connector should be flat against the XM Series Inv...

Page 33: ...omex cable is often used Installation codes may specify solid or stranded overall size of the conductors and type and temperature rating of the insulation around the wire AC wiring must be sized to match the current rating of the AC breakers you provide on the input and output AC circuits in accordance with the electrical codes or regulations applicable to your installation Table 3 3 is based on t...

Page 34: ...C wiring knockout from the front of the unit see Figure 3 5 6 Install a supplied strain relief clamp in the AC knockout 7 Locate the terminal block The two input terminals are labelled as follows N neutral L line A separate screw is provided to connect the AC input ground see Figure 3 5 Table 3 4 Color codes for typical AC wiring Color AC Wire Black Line White Neutral Green or bare copper Ground W...

Page 35: ...ponding terminals 14 Tighten the wire attachment screws to a torque of 1 3 1 8 lbf ft 1 76 2 44 Nm Leave some wiring slack inside the wiring compartment 15 Secure the strain relief clamp 16 See Connecting AC Output to an Existing AC Circuit Figure 3 5 XM Series Inverter AC Wiring Compartment S elect Utili ty Battery Fault ST ATUS XM1000 Input Voltage V Input C urrent A Output P ower W AC IN AC OUT...

Page 36: ...rter For more information about GFCIs see the application note Using GFCI Receptacles on Xantrex Inverters and Inverter Chargers in the Document Library at www xantrex com WARNING Shock hazard Maintain correct wiring polarity Do not connect an AC source such as a generator or utility power to the AC wiring output of the XM Series Inverter The XM 1000 will not operate if its output is connected to ...

Page 37: ...trip approximately 3 8 inch 10 mm off the insulation of each conductor 8 Run the AC cable through the left hand side strain relief clamp and into the wiring compartment 9 Fasten the Ground wire to the grounding screw 10 Using the 1 8 inch slot screwdriver loosen the wire attachment screws on the terminals 11 Insert the Line and Neutral wires into the corresponding terminals 12 Tighten the wire att...

Page 38: ...als chosen 4 Attach the connectors that will join the cables to the battery disconnect battery selector switch and fuse block The connectors you use must create a permanent low resistance connection If you are using crimp connectors use the tool recommended by the terminal manufacturer Make sure no stray wires protrude from the terminal You may find it more convenient to have the crimp connectors ...

Page 39: ...k that the cable you have just installed connects the positive DC terminal of the inverter to the disconnect battery selector switch fuse holder and that the other end of the fuse holder is connected to the positive terminal on the battery CAUTION Loose connections cause excessive voltage drop and may cause overheated wires and melted insulation CAUTION Do not over tighten the nut on the DC input ...

Page 40: ...AC power to operate AC devices The second test is intended for installations where AC input and output is hardwired to the XM Series Inverter The test verifies that the XM Series Inverter transfers from inverter power to shore power when shore power is present When you are ready to test your installation and operate the XM Series Inverter close the DC fuse and Disconnect or the DC circuit breaker ...

Page 41: ...the display panel glows red see the Troubleshooting chapter Testing in Shore Power Mode To test the XM Series Inverter in shore power mode u With the appliance from the previous test still connected and operating connect the shore power source The XM Series Inverter transfers the appliances to shore power The status LED on the display panel glows green If the appliance operates your installation i...

Page 42: ...gsaw drill optional RJ11 extension cord with male and female jacks with a maximum length of 25 feet 7 62 m To install the remote panel in another location 1 Turn the XM Series Inverter off 2 Ensure AC input power is disconnected 3 Remove the two screws securing the remote panel to the XM Series Inverter and set them aside 4 Remove the remote panel and unplug the remote panel RJ11 cord from the jac...

Page 43: ...low space for the remote panel cord to bend 6 Plug the male end of the RJ11 extension cord into the XM Series Inverter 7 Route the RJ11 extension cord through the wall or behind the bulkhead if necessary to emerge from the hole you prepared 8 Plug the jack from the remote panel cord into the female jack on the extension cord 9 Secure the remote panel to the wall with the two screws you removed ear...

Page 44: ...ies Inverter efficiently and effectively Specifically this chapter Gives procedures for operating the inverter from the remote panel Discusses operating limits and inverter loads Discusses battery charging frequency Provides information about routine maintenance ...

Page 45: ...ED Indicates the mode of operation with a three color LED Utility green indicates the XM Series Inverter is in shore power mode using utility power to operate loads connected to the XM Series Inverter Battery yellow indicates the XM Series Inverter is in inverter mode using the battery to provide AC power Fault red indicates the XM Series Inverter has shut down because of a fault Understanding Fau...

Page 46: ...ances Operating in Inverter Mode The XM Series Inverter is in inverter mode when it is using the battery inverting DC to AC to power the appliances connected to the XM Series Inverter Turning the Inverter On and Off The on off button on the remote panel turns the XM Series Inverter on and off When the XM Series Inverter is on and shore power is present the incoming shore power is passed to the out...

Page 47: ...ed the inverter on Turning loads on separately helps to ensure that the inverter does not have to deliver the starting current for all the loads at once and will help prevent an overload shutdown Turning the Inverter Off When Not Used The XM Series Inverter on average draws less than 0 5 A XM 1000 or 0 7 A XM 1800 from the battery when the inverter is on with no load connected However when it is l...

Page 48: ...ds and the display shows fault code E01 alternating with the battery voltage Low Voltage Shutdown Less than 10 5 V The low battery alarm beeps every second and the display shows fault code E02 alternating with the battery voltage The status LED turns red and the inverter shuts down to protect the battery from being over discharged High Voltage Shutdown 15 5 V or more The over voltage alarm beeps e...

Page 49: ...igh Surge Loads Some induction motors used in freezers pumps and other motor operated equipment require high surge currents to start The XM Series Inverter may not be able to start some of these motors even though their rated current draw is within the inverter s limits Trouble Loads Some appliances including the types listed below may be damaged if they are connected to the XM Series Inverter Spe...

Page 50: ...rly Periodically you should Clean the exterior of the unit with a damp cloth to prevent the accumulation of dust and dirt Ensure that the DC cables are secure and fasteners are tight Make sure the ventilation openings are not clogged Batteries When possible you should recharge your batteries whenever a low voltage shutdown occurs with the XM Series Inverter This gives the batteries a much longer l...

Page 51: ...4 8 ...

Page 52: ...his chapter please visit www xantrex com support asp and check the FAQs Frequently Asked Questions for your product Please review this chapter before contacting Xantrex Customer Service If you are unable to solve a problem and need to contact Xantrex record the details on the form Information About Your System on page WA 4 This will help our Customer Service Representatives give you better service...

Page 53: ...rter is solidly connected to the ground system of your vehicle or home 2 Make sure that the television antenna provides an adequate snow free signal and that you are using good quality cable between the antenna and the television 3 Keep the cables between the battery and the XM Series Inverter as short as possible and twist them together with two to three twists per foot This minimizes radiated in...

Page 54: ...ake sure the load does not exceed the XM Series Inverter s output rating Reduce the load if necessary E05 Red Overload shutdown Short circuit Reduce or disconnect the load Make sure the load does not exceed the XM Series Inverter s output rating Check connection to the load E06 Not used E07 Yellow Over temperature shutdown warning Allow the unit to cool off Reduce the load if continuous operation ...

Page 55: ...e Fluke 87 No output voltage The Status LED and the display are off The inverter is off No power to the inverter The inverter could have been connected with reverse DC input polarity No AC power and DC power 15 A supplementary circuit breaker has tripped Turn the inverter on Check the wiring to the inverter and to the disconnect battery selector switch The inverter has probably been damaged Return...

Page 56: ...he inverter s ventilation openings are not obstructed Reduce the ambient temperature Reduce the load Make sure the load does not exceed the XM Series Inverter s output rating Remove the short circuit No output voltage with shore power connected Shore power has dropped below 90 V GFCI has tripped 15 A supplementary circuit breaker has tripped Check shore power voltage Turn inverter on Check load an...

Page 57: ...5 6 ...

Page 58: ... power 5 minutes 1000 W 1200 W 1800 W n a Surge rating 2000 W 3600 W Output voltage 115 VAC RMS 10 Output waveform Modified sine wave Output frequency 60 Hz 1 Hz DC input voltage range 10 5 15 5 VDC DC low voltage alarm 11 0 V DC low voltage cutout 10 5 V DC low voltage recovery 12 0 V Over voltage cutout 15 5 V AC pass through low voltage cutout 90 V AC pass through low voltage recovery 100 V Opt...

Page 59: ... 2 975 0263 01 01 Physical Specifications XM 1000 XM 1800 Length 12 13 16 inches 326 mm 14 9 16 inches 370 mm Width including mounting flanges 9 inches 230 mm Height 4 inches 102 mm Weight 7 5 lb 3 4 kg 10 8 lb 4 9 kg ...

Page 60: ...Mounting Dimensions 975 0263 01 01 A 3 Mounting Dimensions Figure A 1 XM 1800 Mounting Dimensions ...

Page 61: ...Specifications A 4 975 0263 01 01 Figure A 2 XM 1000 Mounting Dimensions ...

Page 62: ...amiliar with is probably the starting battery in your vehicle An automotive starting battery is designed to deliver a large amount of current for a short period of time so it can start your engine Only a small portion of the battery s capacity is used when starting the engine and the spent capacity is quickly recharged by the running engine The starting battery in your vehicle is not designed for ...

Page 63: ...g the charge Figure 3 1 DC Input Configuration for Normal Loads on page 3 2 and Figure 3 2 DC Input Configuration for Heavy Loads on page 3 3 show a battery isolator in configurations for normal and heavy duty loads Battery isolators are available at marine and RV dealers and most auto parts stores Battery Size Battery size or capacity is as important as the battery type for efficient operation of...

Page 64: ...specified length of time usually 20 hours For example a typical marine or RV battery rated for 100 Ah can deliver 5 amps for 20 hours 5 A 20 hours 100 Ah This same battery can deliver a higher or lower current for less or more time limited approximately by the 100 Ah figure for example 50 A for 2 hours or 200 A for 1 2 hour but usually the capacity figure given is only accurate at the specified ra...

Page 65: ...es by 10 This gives the battery Ah used between charges 6 Double the total Ah used between charges to get the recommended battery size in Ah See the battery sizing example that follows Battery Sizing Example This battery sizing example illustrates a typical calculation assuming an opportunity to charge the batteries every three days Appliance A Power Consumption Watts B Operating Time per Day Hour...

Page 66: ...e is directly dependent on how deeply the battery is discharged The deeper the discharge the shorter the battery life Battery Sizing Worksheet Use the following worksheet to calculate your battery needs To ensure sufficient battery capacity be generous when estimating the operating time per day for each of the loads you will run Appliance A Power Consumption Watts B Operating Time per Day Hours Da...

Page 67: ...r Heavy Loads on page 3 3 show a battery configuration that is recommended for heavy loads Two Separate Battery Banks If you need more than two batteries or are using different makes or models of batteries Xantrex recommends that you install two separate battery banks and a battery selector switch Figure 3 2 DC Input Configuration for Heavy Loads on page 3 3 shows two separate battery banks and a ...

Page 68: ...ed battery enclosure is recommended High Temperatures The batteries should also be protected from high temperatures These can be caused by high ambient temperatures solar heating of the battery enclosure or heat released by a nearby engine or generator High battery temperatures shorten battery life and therefore you should ventilate the enclosure and use shade and insulation as appropriate Dischar...

Page 69: ...ne Battery State of Charge You can measure battery state of charge with a hydrometer or approximate state of charge with a voltmeter Use a digital voltmeter that can display tenths or hundredths of a volt when measuring 10 to 30 volts Make your measurements when the battery has not been charged or discharged for several hours For a deep cycle battery at 77º F 25º C use the following table Battery ...

Page 70: ...hould be capable of delivering a charging current equal to 25 of the amp hour capacity of your battery For example if you have a 200 Ah battery the charging system should be able to deliver 50 amps The charging system must also be able to charge each 12 volt battery up to approximately 14 4 volts and then drop back to a float voltage of 13 5 14 volts or shut off CAUTION Never operate the inverter ...

Page 71: ...eliver even less as battery voltage rises Many alternators cannot produce more than 13 6 volts when they are hot As a result a standard alternator may not be able to charge a large battery quickly and completely Two solutions are to install an alternator controller or to install a high output alternator Using an Alternator Controller If your regular alternator is inadequate you can install an alte...

Page 72: ...ional recharging of automotive starting batteries These chargers are not intended for continuous use Charging From Alternative Energy Sources You can also charge your batteries from alternative energy sources such as solar panels wind or hydro systems Make sure you use the appropriate battery charge controller for your particular energy source CAUTION Never operate the XM Series Inverter directly ...

Page 73: ...C 4 ...

Page 74: ...ary to repair the product and return shipment to the customer via a Xantrex selected non expedited surface freight within the contiguous United States and Canada Alaska and Hawaii are excluded Contact Xantrex Customer Service for details on freight policy for return shipments outside of the contiguous United States and Canada How do you get service If your product requires troubleshooting or warra...

Page 75: ...PLIED STATUTORY OR OTHERWISE IN CONNECTION WITH THE PRODUCT HOWEVER ARISING WHETHER BY CONTRACT TORT NEGLIGENCE PRINCIPLES OF MANUFACTURER S LIABILITY OPERATION OF LAW CONDUCT STATEMENT OR OTHERWISE INCLUDING WITHOUT RESTRICTION ANY IMPLIED WARRANTY OR CONDITION OF QUALITY MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOS...

Page 76: ...rchase Record these details in Information About Your System on page WA 4 Return Procedure 1 Package the unit safely preferably using the original box and packing materials Please ensure that your product is shipped fully insured in the original packaging or equivalent This warranty will not apply where the product is damaged due to improper packaging 2 Include the following The RMA number supplie...

Page 77: ...our Xantrex PRO XM Series Inverter package record the following information and be sure to keep your proof of purchase If you need to contact Customer Service please record the following details before calling This information will help our representatives give you better service p Product Numbers 806 1010 XM 1000 806 1810 XM 1800 p Serial Number on DC end _________________________________ p Purch...