32
Xanbus System Control Panel (SCP) Owner’s Guide
Troubleshooting
W252
Please confirm:
Restore default
settings.
Manual
You have selected
the Restore Defaults
command.
Press
Enter
to restore
default settings or
Func
to cancel.
W254
The value failed to
change. Try again.
Manual
The setting you are
changing can only
be changed when
the system is in
Standby mode.
Put the system in
Standby mode, change
the setting, then return
the system to
Operating mode.
W255
System clock not
set. Set correct
time.
Manual
On initial startup,
the clock needs to be
set. The system will
not operate correctly
until it is.
Set the clock to the
correct time. See
“Using the Clock
Menu” on page 21.
W256
A device is lost.
Check connection.
Manual
The SCP has lost
communications
with another device
on the network.
Check network
connection between
the SCP and the
device.
W257
New device
detected.
Check device
settings.
Manual
You have connected
a new device to the
network or
reconnected a
disconnected
device.
Acknowledge the
message and check
that the device is
properly configured.
W258
Device instance
is duplicated.
Manual
Two networked
devices of the same
type have the same
instance.
Select a different
instance ID on one of
the devices’ Setup
menu.
Table 1
Warning Reference Table
Warning
number
Message
Type
Cause
Action
W501
SCP has fixed a
memory problem,
restored defaults.
Manual
The SCP
encountered an
internal memory
problem upon
startup. To remain
operational, the SCP
restored its default
settings.
Acknowledge the
warning and reset
configurable settings
if necessary.
W502
Not reporting;
Info may be
missing.
Manual
Table 1
Warning Reference Table
Warning
number
Message
Type
Cause
Action