16
Xanbus System Control Panel (SCP) Owner’s Guide
Xanbus-Enabled Device Configuration Using the SCP
Changing Settings for a Device
You can view and change device settings from the device setup menu.
Basic menu
Each Device Setup menu can be displayed in Basic and
Advanced formats. The Basic menu contains configuration items you may
have to adjust routinely, or as part of initial setup.
Advanced menu
The Advanced menu gives you access to the full set of
configuration menus for that device, including everything displayed on the
Basic menu. As a safeguard against unintended advanced configuration, the
SCP displays the Basic menu by default. To view the Advanced menu, you
must perform a special keypress.
To view the Advanced menu:
◆
On the Device Setup menu, press
Enter
+ up arrow + down arrow at
the same time.
Identifying changeable settings
A Device Setup menu displays
changeable settings and commands to view other menus. Changeable
settings are enclosed in square brackets.
To select and adjust a setting:
1.
On the Device Setup menu, press the up arrow or down arrow button
to highlight the setting you want to change.
2.
Press
Enter
to highlight the current value of that changeable setting.
The previously set value appears with an asterisk (*) beside it.
FIRE AND ELECTRICAL SHOCK HAZARD
The Advanced settings for devices other than the SCP are intended for
qualified installation/service personnel only. Before changing advanced
settings, you must be familiar with the settings and the system-wide
impact of changing those settings. Setting parameters incorrectly could
damage connected equipment (such as batteries) or could severely affect
the performance of your system. Incorrect charging configuration can
lead to battery damage and risk of fire. Consult the local utility before
enabling sell mode or changing sell mode settings.
Failure to follow these instructions can result in death or serious
injury.
NOTE:
This keypress combination, if applicable to the device, displays
advanced menus for every device in the system.
FSW3012 00: Setup
Inverter
Search Mode
Charger
Force Chg
[Enabled]
[Disabled]
[Enabled]
Basic menu shown.