Installation
3–38
976-0043-01-02
Install Utility Wiring to the Inverter Input (On-Grid Applications only)
The following instructions are illustrated in
Figure 3-21, “Utility Wiring
to the Inverter Input” on page 3–39
.
Install the wiring from the inverter to the utility panel as follows:
1.
Feed the HOT, NEUTRAL, and GROUND input wires (via conduit)
from the inverter to the utility panel. Leave three to six inches of extra
wire at each end.
2.
Connect a GROUND (green or bare) wire:
a) from the inverter AC GROUND bar, and
b) to the utility panel GROUND bar.
3.
Connect a NEUTRAL (white) wire:
a) from the inverter NEUTRAL 1 terminal, and
b) to the utility panel NEUTRAL bus.
4.
Connect a HOT (black) wire:
a) from the inverter AC1 GRID terminal, and
b) to the appropriate utility panel circuit breaker.
5.
Torque all inverter terminal block connections to 25 inch-pounds.
CAUTION: Damage to Equipment
The inverter’s AC output must never be wired to any AC source voltage such as a
generator output or utility panel. This will cause severe damage to the inverter
which is not covered under warranty.
Important:
Make the connections to the inverter first. Wiring to the inverter’s
main breaker in the utility panel is performed after all connections have been
made in the inverter.
Summary of Contents for SW Plus 2524
Page 2: ......
Page 3: ...Sine Wave Plus Inverter Charger Owner s Manual...
Page 82: ...2 48...
Page 105: ...DC Wiring 976 0043 01 02 3 23 Figure 3 13 DC Connections to a Single Inverter...
Page 107: ...DC Wiring 976 0043 01 02 3 25 Figure 3 14 DC Connections to Dual Inverters...
Page 126: ...3 44...
Page 132: ...4 6...
Page 141: ...Menu Map 976 0043 01 02 5 9 Figure 5 10 User Menu Map Part 2...
Page 143: ...Menu Map 976 0043 01 02 5 11 Figure 5 12 Basic Setup Menu Map Part 2...
Page 145: ...Menu Map 976 0043 01 02 5 13 Figure 5 14 Advanced Setup Menu Map Part 2...
Page 146: ...Navigation 5 14 976 0043 01 02 Figure 5 15 Complete User Menu Map...
Page 147: ...Menu Map 976 0043 01 02 5 15 Figure 5 16 Complete Basic Setup Menu Map...
Page 148: ...Navigation 5 16 976 0043 01 02 Figure 5 17 Complete Advanced Setup Menu Map...
Page 250: ...8 32...
Page 274: ...A 16...
Page 308: ...C 18...
Page 312: ...D 4...
Page 316: ...E 4...
Page 338: ...I 6...
Page 342: ...Index IX 4 976 0043 01 02...
Page 343: ......