Diagram 3
(
3 Banks
)
In this twin engine, three-battery bank installation, each engine has a
dedicated starting battery. All batteries are charged when either of
the engines is running, or when there is any charging source on the
system. In an emergency all batteries may be connected together
using the optional Remote Switch. This diagram is shown without
any battery switches, since a PathMaker can replace battery switches.
Note: Install Negative (
ground
) to PathMaker last.
Fusing, breakers, wire size, and optional battery switches that may be
required by ABYC or NEC are not shown.
+ -
START 1
- +
START 2
+ -
HOUSE
ENGINE
# 1
PATHMAKER
ALT
STARTER
VB2
VB3
VB1
NEGATIVE
TO DC LOADS
+
ENGINE
# 2
ALT
STARTER
Summary of Contents for PathMaker