Troubleshooting Reference
975-0784-01-01
79
Problem
Possible Cause
Solution
No output voltage. The status LED is
not lighting up.
Ignition lock (ACC) signal is not
present.
If the ignition control feature is in use, ensure the
vehicle’s ignition is On and the ignition control switch on
the front of the Freedom XC unit is On (|).
The fan turns on and off during AC
shore power mode.
The battery is discharged.
AC pass-through current is high.
Do not be alarmed, the unit is performing normally.
The fan turns on and off during inverter
mode.
The inverter is running
continuously at high power.
Do not be alarmed, the unit is performing normally. The
fan is activated automatically.