Supported AC input types
Single input (up to 30 amps)
Split phase (up to 30 amps per line)
Dual input (up to 30 amps per line)
Transfer and General Specifications
All Models
Transfer time—utility to invert
< 20 ms
Minimum AC input voltage for transfer
85 VAC
Maximum AC input voltage for transfer
135 VAC
Minimum AC input frequency for transfer
45 Hz
Maximum AC input frequency for transfer
70 Hz
Cooling
Fan-cooled, temperature controlled.
Regulatory Approvals
All Models
Safety
CSA 107.1,
UL 458 5th Ed. with marine supplement,
ABYC E11 - Alternating Current and Direct Current Electrical Systems on Boats, and
ABYC A31 - Battery Chargers and Inverters.
EMC
FCC Part 15, Class B
Industry Canada ICES-003, Class B