Default Settings
8
Freedom XC PRO Owner's Guide
WARNING
ELECTRICAL SHOCK HAZARD
Use a torque screwdriver to tighten the captive nut panel screw to
5 in-lb torque of force to ensure a proper ground connection and a
required tool access to the wiring compartment.
Failure to follow these instructions can result in death, serious
injury, or equipment damage
.
Feature
Description
1
Captive nut panel screw
holds the AC compartment
cover in place. See WARNING above.
2
Ventilation grille
(openings) must not be obstructed.
3
Grounding lug
provides a ground path for the
Freedom XC PRO chassis to the DC system ground.
See WARNING.
4
DC terminal
opening for routing (–) negative DC
cable.
5
DC terminal
opening for routing (+) positive DC
cable.
6
LED indicator
for reverse DC polarity.
Table 2 AC/DC and GFCI Panel Features
Feature
Description
7
AC output terminal opening
for routing AC output
wiring.
8
AC input terminal opening
for routing AC input
wiring.
9
USB port
can only be used for updating the unit’s
firmware. It is not used for powering USB devices.
10
LED indicator
for communication and control
activation.
11
BTS port
can be used for plugging in a battery
temperature sensor [BTS (PN: 808-0232-01), sold
separately].
12
Remote port
allows you to connect the Freedom X
Remote Panel with cable (PN: 808-0817-01) (sold
separately) which is a remote control device
accessory.
13
20-pin CC (communications and control) port
connects with the optional 20-pin Communications
Harness (PN: 808-0820) (sold separately).
14
GFCI cover
is removed when installing a qualified
GFCI device.