Operating During Transition Between Grid Mode and Battery Mode
74
Freedom XC PRO Owner's Guide
Setting Name
Setting
Number
Default
Value
Range of
Values
Description
Battery Temperature
21
HOt
CLD
(Cold)
VRM
(Warm)
HOT
(Hot)
Selecting Cold from Warm will increase charger voltage by 0.4V.
Selecting Cold from Hot will increase charger voltage by 0.8V.
Custom Absorption
Voltage
22
14.6
12
.
0
to
18
.
0
The voltage setting value can be adjusted by 0.1 increments.
Available only when custom battery type is selected.
Custom Float Voltage
23
13.5
12
.
0
to
18
.
0
Charger Current
(Freedom XC PRO
2000)
24
100
5
to
100
The current setting value can be adjusted by 5A increments.
Charger Current
(Freedom XC PRO
3000)
24
150
5
to
150
Charger Ignition Control
26
OFF
OFF
(OFF)
AT0
(Auto-ON)
See
Description of Ignition Control Features on page 40
Equalize Charging for
Flooded Battery
27
DIS
ENA
(enable)
DIS
(disable)
This setting is only available when Flooded battery type is
selected. It allows only one hour of equalize charging once.