22
Freedom X Owner’s Guide
Basic Installation Procedures
AC Input Connections
1. Ensure AC and DC power sources are turned off.
2. Install the required circuit breaker in the AC distribution panel
supplying AC power to the unit.
3. Remove the AC compartment cover by loosening the captive
nut panel screw and lifting the cover up and out.
captive nut panel screw
4. Strip a single AC input wire, as appropriate.
5. Remove the knockout and install a ½" strain relief clamp.
6. Route the wires through the strain relief clamp (not shown in
the figure).
N
L
G
AC Input knockout
NOTE
: install a strain
relief clamp (not shown)
10mm
to circuit
breaker
•
N
•
G
•
L
7. Locate the Neutral, Ground and Line terminals on the AC input
terminal labeled as
N
,
G
, and
L
respectively.