background image

 

 

Do not install near any heat sources such as radiators, heat registers, stoves, 
or other apparatus (including amplifiers) that produce heat. 

 

In the unlikely event that smoke, abnormal noise, or strange odor is present, 
immediately power the MRKP1E off. Please report the problem to your dealer 
immediately. 

 
Never attempt to disassemble the MRKP1E.  You will lose any product warranty 
on the unit. 

 

 

 

20 

6. Specifications 
 

 

 

MRKP1E basic dimensions and cable lengths 

Front panel dimensions 

80mm height x 83.8 width x 15.3mm thick 
3.15” height x 3.3” width x 0.6” thick 

Wall Hole size   

69mm (2.7”) diameter hole when using 
compatible EU back box. 

Unit Depth in-wall 

43.2mm (1.7”) depth when using compatible 
EU back box 

Max length Cat-5 Cable 
with 1 keypad 

152 meters  (500 feet) total per zone 

Max length Cat-5 cable 
with 1 keypad and 1 
expansion keypad  

77 meters (250 feet) total per zone 

Max length Cat-5 cable 
with 1 keypad and 3 
expansion keypads  

38 meters (125 feet) total per zone 

Operating 
Temperatures & 
Environments 

Operating Temperature: 32-104°F (0-40° C) 
Humidity: 0-90% 

 

 

 

Compatible Electrical back-boxes 

EU back-box 

Legrand® 801 01, EAN 3 245060 905019 
(40mm Depth x  60mm Inner Diam.) 

UK back-box 

 

Standard UK one-gang 47mm depth 

 

 

 
 

 

 

 

Extending external IR receiver 

connection with 3-wire cable 

Extending external IR 

receiver connection  

Size (AWG) 

Maximum allowable 
length (feet) 

with Cat-5 cable using all 8 

conductors 

24 

150 

  Use 4 striped wires for GND 

22 

300 

  Use 2 solid wires for IR signal 

20 

1000 

  Use 2 solid wires for +12V  

18 

2000 

 

 

 

 

 

Summary of Contents for MRKP1E

Page 1: ...INSTALLATION INSTRUCTIONS MRKP1E Keypad controller EU and UK Standard...

Page 2: ...ge in performance or The appliance has been dropped or the enclosure damaged Replacement Parts When replacement parts are required be sure the service technician has used replacement parts specified b...

Page 3: ...and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this...

Page 4: ...1 7 depth when using compatible EU back box Max length Cat 5 Cable with 1 keypad 152 meters 500 feet total per zone Max length Cat 5 cable with 1 keypad and 1 expansion keypad 77 meters 250 feet tota...

Page 5: ...r NOTE MRC88m MRAUDIO8X8m must have Firmware ver 2 03 or later to work with the MRKP1E About the MRC88m System The Xantech MRC88m System is the next generation in Whole house Audio Video Entertainment...

Page 6: ...ning room master bedroom master bath or for multiple zones to be contained in one room game room bar area or multiple zones in the yard Local Source Source A Source is any audio or audio video device...

Page 7: ...r prior to the pre wire stage After establishing design goals make a detailed list of all components Include source equipment keypad expansion hubs local source wall plates IR emitters etc Pre Constru...

Page 8: ...BASS Adjust the lower frequency range of audio output The settings can be adjusted from 14 to 0 middle to 14 BL COLOR Gives option to change the Text color and keypad backlighting to Blue or Green GO...

Page 9: ...el number Keypad Address and Version number USER SETUP allows adjustments of BALANCE BASS TREBLE and BACKLIGHT Color INST SETUP Allows installer to configure the unit for initial setup and other optio...

Page 10: ...nt such as a Local Source DVD Player A V Receiver etc A CAT 5 cable can be used to extend the IR receiver s wire if necessary Refer to the bottom of the Specifications page for wiring instruction when...

Page 11: ...x J Box see Specifications sections for details Typical mounting height is 56 60 inches 1 53 meters from the floor to the bottom of the frame This provides optimum viewing for the largest number of pe...

Page 12: ...d the MRC88m Connect CAT 5 cables terminated to an RJ 45 connector from each Keypad to the corresponding RJ45 connector of the MRC88m as shown below See Specifications section for maximum length of Ca...

Reviews: