POWER SUPPLY CONSIDERATIONS

The total current available from the +12V and STATUS terminals on the EXP9 to power keypads, infrared
receivers, switching devices, etc., is 1.8 A.  In addition, each of the zone STATUS terminals have a current
limit of 90 mA each max.  These currents are enough to power all but the most unusual installations.
However, if you have a system where the total current demand exceeds 1.8 A, then an external power
supply(s) must be used to power the extra devices to prevent overheating and shutdown of the
EXP9.

The following list shows the current required by Xantech devices typically used with EXP9's (and ZPR68-
10's) in multi-zone systems:

DEVICE

CURRENT DEMAND

IR Receiver Models

291-10, 480 series, 490/495 series, 780-10

10 mA

291P, 291-455, 780P, 780-455(hi-frequency types)

15 mA

291-80, 780-80 (CFL types)

20 mA

780-80 CFL Status LED

10 mA

Chart continued on next page

DEVICE

CURRENT DEMAND

Keypad Models

730 Smart Pad

65 mA

Smart Pad

2

 (PM1, LM1, WPK series)

85 mA

Smart Pad

2

 Status line (PM1, LM1 & WPK series)

5 mA

Models With Control Inputs

PA640 Six Channel Power Amplifier

11 mA

599 Pulsed Switching Module

11 mA

CC12 and SR21 Relay Modules

 1 mA

Procedure

Add up the current demands for the devices used in the system.  If the total current exceeds 1.8 A, it is then
necessary to use a 782-00 power supply to separately power the V or +12V terminals of the additional
devices that cause the over-current condition.  See typical connection diagram, Fig. 5.

Note:  The STATUS or Control Inputs of the devices must remain connected to the respective zone
STATUS terminals on the EXP9, where used.  Also, if you exceed 90 mA on any one of the STATUS
terminals, use a Xantech CC12 Remote Relay Module to reduce the current demand.  Refer to the CC12
Installation Instructions, Fig. 6, for details.

Example 1

Four Smart Pad

2

's (with Status) and five 780-80's (with Status), are connected to the zones on the EXP9.

Add up the currents: (4 x 90 mA) + (5 x 30 mA) = 510 mA total.  This is well within the 1.8 A (1800 mA) limit.
Therefore, no external power supply is needed.

Example 2

24 Smart Pad

2

's (2 in some zones, 3 in others, with Status) and eighteen 780-80's (2 per zone, with Status),

are connected to the zones on the EXP9.  Add up the currents: (24 x 90 mA) + (18 x 30 mA) = 2700 mA  total
current.   This exceeds the 1.8 A limit by 900 mA.  Therefore, a 782-00 external power supply is needed
to power the extra Smart Pad

2

's and IR receivers that cause the 1.8 A limit to be exceeded. In this case,

you could power eleven Smart Pad

2

's externally (11 x 85 mA = 935 mA) to ease the load sufficiently.

EXP9

Summary of Contents for EXP9

Page 1: ...or in field expansion Whenreceivedfromthefactory unusedzoneopeningsarecoveredfromunderneathwithindividualcover plates These are removed as needed when additional zone XCARDs are installed in the field...

Page 2: ...s receiving IR commands from an IR receiver keypad etc 4 I O PORT These multi pin connector jacks provide an input output port This allows the EXP9 to be linked with a ZPR68 10 via two large ribbon ca...

Page 3: ...lly align the holes in the top cover with the jacks and the LEDs on all the PCB s before pressingitdownintoplaceandreplacingthescrews CONNECTING THE EXP9 TO A ZPR68 10 To make the necessary con nectio...

Page 4: ...es in the top cover with the jacks and the LEDs on all the PCB s before pressing it down into place and replacing the screws INSTALLATION To install the ZPR68 10 EXP9 combination into the application...

Page 5: ...dd up the current demands for the devices used in the system If the total current exceeds 1 8 A it is then necessary to use a 782 00 power supply to separately power the V or 12V terminals of the addi...

Page 6: ...a system that is so extensive that the total current exceeds the 1 8 A limit of the EXP9 by more than 1000 mA use two 782 00 s connected so that two separate 12V DC rails are created Connect two group...

Page 7: ...a different number The drawback to this solution is that you would need dedicated learning remotes if used for the rooms having the different IR Code Groups 4 I have two or more zone dedicated same br...

Page 8: ...Max Total Current Available From 12V STATUS Terminals 1 8 A Power Requirements 14V 0 14V AC 2 7 A 8V 0 8V AC 0 7 A Multi Voltage Power supply included Gold Plated RCA type phono jacks All A V inputs...

Reviews: